Kualitas Citra CT Abdomen Non Kontras Berdasarkan Variasi Rotation Time (Studi Penelitian dengan Menggunakan Phantom) Dyah Arum Larasati; Gatot Murti Wibowo; Sri Mulyati
Jurnal Imejing Diagnostik (JImeD) Vol 3, No 1: January 2017
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v3i1.3182

Abstract

Backgroud: Has conducted research in Radiology Department of RS Telogorejo Semarang regarding image quality of CT Abdomen non contrast based on variations of rotation time in phantom, especially noise and spatial resolution. This study was conducted to determine the difference in rotation time variation of the image quality (noise and spatial resolution) on a non-contrast CT abdomen and know the value rotation time is used in order to produce optimal image quality with the variations of the rotation time of 0.5 s, 0, 6 s, 0.7 s, 0.8 s, 0.9 s and 1.0 s.Methods: This research is a quantitative study with an experimental approach. Data have been collected from December 2016 to January 2017 in Radiology Department of RS Telogorejo Semarang. CT abdomen non-contrast examinations performed by using the modality of 64 slice CT scan and the data collected by assessing noise and spatial resolution in phantom. Further, data were tested with data normality test then the statistical test by Kruskal Wallis test has been used to determine the difference in image quality was noise and spatial resolution on non-contrast abdominal CT followed by Post Hoc test Mann Whitney on spatial resolution to determine a significant difference between the variation of rotation time .Results: The results of this study showed significant differences in spatial resolution with p value 0.001 and there were no significant difference in the value of noise with p value 0.001 non-contrast abdominal CT.Conclusion: Values optimal rotation time for CT Abdomen non contrast with variation of the rotation time are 0.5 s, 0.6 s, 0.7 s, 0.8 s, 0.9 s and 1.0 s for the spatial resolution is 0.6 s and 1.0 s for the noise.
Analisis Informasi Citra MRI Genu Potongan Aksial antara Sekuen Short TAU Inversion Recovery (STIR) dan Sekuen T2-Spectral Attenuation Inversion Recovery (T2-SPAIR) Thuthit Dwi Astuti; Emi Murniati; Sri Mulyati
Jurnal Imejing Diagnostik (JImeD) Vol 2, No 1: January 2016
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v2i1.3165

Abstract

Backgrounds: Genu MRI examination, according to Moeller (2003) and Westbrook (2008), was done by one fat supression technique in every slice. Radiology Installation of PAU dr.S.Hardjolukito Yogyakarta Hospital used two types of fat suppression technique those are STIR and T2-SPAIR. This study aims to find out the image differences between STIR and T2-SPAIR and to determine the fat suppresion technique that produces better image information of axial genu MR imaging.Methods: This research was a quantitative research with an experimental approach. Subjects of this study was image of axial genu MRI examination between STIR and T2- SPAIR in Radiology Installation of PAU dr.S.Hardjolukito Yogyakarta Hospital. The axial genu MR imaging STIR and T2-SPAIR assessed by three radiology phisicians using questioner. Data were statistically analyzed using Wilcoxon Sign Test.Results: The results showed a significant difference in all categories of assessment criteria between STIR and T2-SPAIR. In this study, the T2-SPAIR fat suppression technique produced better image information than STIR, whereas T2-SPAIR fat suppress signals was stronger than STIR.Conclusion: T2-SPAIR fat suppress signal was stronger than STIR that showed better image information and shorter time scanning
Analisis TSE Factor Terhadap Signal to Noise Ratio dan Contrast to Noise Ratio pada Pembobotan T2 Turbo Spin Echo Potongan Axial MRI Brain Novelsa Chintya Prabawati; Siti Masrochah; Sri Mulyati
Jurnal Imejing Diagnostik (JImeD) Vol 3, No 2: July 2017
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v3i2.3198

Abstract

Background: TSE factor is parameters that affect Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR). TSE factor for brain MRI examination is a long TSE factor. There are differences when using TSE factor. At the theory, the brain MRI examination is using TSE factor ≥16 while at Siloam  Surabaya  Hospital was using TSE factor 14. The writer ever seen some noises at brain MRI image therefore the radiographer doing modification of TSE factor. The purpose of this research are to determine the influence of modification in the TSE factor value against SNR and CNR and to define the SNR and CNR optimum from that.Methods: This research is a quantitative study with an experimental approach. This research was done by MRI Philips Achieva 1,5 T with 10 modification TSE factor (8, 10, 12, 14, 16, 18, 20, 22, 24 and 26). SNR and CNR obtained by measurement of ROI in the grey matter, white matter and CSF with the result an average signal and compared with the average standard deviation of the background image. Data was analyzed by linear regression test to know the influence of TSE factor against SNR and CNR and data was analyzed by descriptive test mean rank to obtain the optimum TSE factor value.Result: The result showed that there was the inluence of TSE factor to SNR and CNR at T2W TSE axial brain. There was a significant correlation between TSE factor with all of area SNR and CNR with coefficient correlation of SNR grey matter r=0,591, with coefficient correlation of SNR white matter r=0,604, with coefficient correlation of SNR CSF r=0,687, with coefficient correlation of CNR CSF–grey matter r=0,690, with coefficient correlation of CNR CSF-white matter r=0,658. The significant value of linear regression test is (0,000*) p value (0,05). TSE factor optimum value at T2W TSE axial brain was TSE factor value 10 for SNR with mean rank SNR 45,05 and TSE factor value 8 for CNR with mean rank CNR 35,43.Conclusion: There was the influence of TSE factor to SNR and CNR at T2W TSE axial brain. TSE factor optimum value in brain MRI T2W TSE axial is 10 to SNR and TSE factor 8 to CNR.