Jeffry Ardiyanto
Jurusan Teknik Radiodiagnostik dan Radioterapi Poltekkes Kemenkes Semarang

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

ANALISIS PERBEDAAN INFORMASI ANATOMI PADA PEMERIKSAAN CT SCAN ABDOMEN ANTARA PENGGUNAAN PROTOKOL SURE EXPOSURE DAN TANPA SURE EXPOSURE Devita Rizkania Indarsari; Jeffry Ardiyanto; Andrey Nino Kurniawan
Jurnal Imejing Diagnostik (JImeD) Vol 5, No 2: July 2019
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v5i2.4468

Abstract

Background : Image quality Abdomen CT scan is said to be either indicated by low noise or image noise values within acceptable standard limits. One of the parameters affecting image noise is mAs. On CT Scan aircraft there is an auto mAs setting facility called Sure exposure to ensure constant image quality at the lowest possible dose. The purpose of this study was to determine the difference of anatomical information to the use of sure exposure protocol and without sure exposure on CT scan of Abdomen and to know better protocols in producing quality on CT Scan Abdomen between usage protocol sure exposure and without sure exposure.Method : This research is a kind of quantitative research with experimental approach. This study used the CT Scan Multislice 128 plane on CT scan of Abdomen with the use of sure exposure protocol and without sure exposure. The results were obtained based on respondents assessment through Liver, Spleen, Adrenal Gland, Kidney, Pancreas and Abdominal Wall. Analyze this research data using statistical test.Result : The results of the questionnaires of respondents on liver, spleen, adrenal gland, kidney, pancreas and abdominal wall showed no significant difference. This is followed by the value of Mann Whitney's overall significance of the abdominal anatomy is 0.549 (p value 0.05). Protocol Sure Exposure is better on the organ of adrenal glands, kidneys and pancreas, whereas protocols without sure exposure are better in liver, spleen, kidney, pancreas, and abdominal wall. The use of protocols without sure exposure better in generating information.Conclusion : In general the protocol of sure exposure and without sure exposure has the same clarity of anatomical information. But the protocol without a sure exposure has more information than the sure exposure protocol.
PERBANDINGAN INFORMASI CITRA ANTARA SEQUENCES T2 FAST FIELD ECHO DAN SUSCEPTIBILITY WEIGHTED IMAGING PADA PEMERIKSAAN MRI BRAIN IRISAN AXIAL DENGAN KASUS MICROBLEEDS Afandi; Luthfi Rusyadi; Fatimah; Jeffry Ardiyanto
JRI (Jurnal Radiografer Indonesia) Vol. 1 No. 1 (2018)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (429.391 KB) | DOI: 10.55451/jri.v1i1.3

Abstract

Background : The Gradient echo sequence is a sequence using RF excitation pulse varied and with flip NMV through various angle (Instead of 900). It’s sensitive in detecting the present of hemorrhages that have susceptibility and blooming effect to hemorrhages. T2 fast field echo (T2 FFE) and susceptibility weighted imaging (SWI) are part of the gradient echo pulse sequences, in which T2 FFE sequences is conventional non- steady state imaging 2D milti-slice and SWI is 3D velocity compensated sequence gradient echo. On both the sequence is very good for asses the hemorrhages particularly microbleeds. This study aims to determine differences in image information and determine the most optimal image information between T2 FFE and SWI sequences in brain MRI axial slices with microbleeds cases. Methods : Type of research is quantitative experimental approach. The data was taken from October to November 2016 at Radiology Installation of Siloam Hospital Lippo Village. The study populations was all examinations brain MRI with the microbleeds cases, 5 samples with inclusion criteria described. Scanning by using T2 FFE and SWI sequences, then evaluation by respondents furthermore the data was processed using kappa test, and analyzing the date using wilcoxon test, and then to get an assesment of the most optimal images seen from the mean rank wilcoxon test. Results : The result was p-value 0,025 (p<0,05) means that Ho refused and Ha accepted, so that statistically showed significant differences at images information between T2 FFE and SWI sequences in examinations brain MRI axial slices with microbleeds case, with mean rank on SWI sequence is 3, and mean rank on T2 FFE is 0, so it’s can be concluded that SWI sequence produces a better images information on the examination brain MRI axial slices with microbleeds cases than T2 FFE sequence. Conclusion : there is a difference of images information between T2 FFE and SWI sequences in Brain MRI axial slices with microbleeds cases, and SWI sequences produces a better images information on the Brain MRI axial slices with microbleeds cases.