Very Richardina
Departemen Fisika, Fakultas Sains dan Matematika, Universitas Diponegoro, Semarang

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Analisis Pengaruh Dosis Radiasi Eksternal Akumulasi Dosis yang Diterima Petugas Radiasi di Ruang Penyinaran Radioterapi RSUP dr.Hasan Sadikin Bandung Budi Muhammad AR; Eko Hidayanto; Very Richardina
Youngster Physics Journal Vol 7, No 2 (2018): Youngster Physics Journal April 2018
Publisher : Jurusan Fisika, Fakultas Sains dan Matematika, Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (502.439 KB)

Abstract

In radiation utilization, the regulation should be applied to minimize radiation dose received by the officer in order not to exceed the provision of Dose Limit Value based on BAPETEN Regulation No. 4 of 2013 that the average of equivalent dose is ≤50 mSv/year and ≤20 mSv for five-year period. The purpose of this study was to analyze the external radiation dose received by each officer at Radiotherapy Installation RSUP dr.Hasan Sadikin Bandung based on the NBD that has been determined. The equivalent dose values were obtained from the Thermoluminisence Dosemeter (TLD) of each officer over a five-year period from 2012 to 2016 that had been read by using a TLD reader. Then the radiation exposure measured by using a surveymeter with a distance of 3 meters from each teleterapi aircraft with radioactive sources to predict the distance factor between officers and radiation sources. The results showed that teleterapi operators received the highest equivalent dose in a five-year period with a dose value of 0.206 mSv/year, then in 2013 the external radiation dose received by officers and medical physicists reached the highest value when compared to another officers, with the average value of equivalent dose was 0.085 mSv/year and 0.55 μSv/hour. If observed from the distance factor, in 2013 each officer tends to come near to the source of radiation at every working hour. All radiotherapy officers at RSUP dr.Hasan Sadikin Bandung from 2012 to 2016 received a safe radiation dose and not exceed the NBD determined by BAPETEN. Keywords: Dose Limit Value, External Radiation Dose, Equivalent Dose, Distance
Analisis keakuratan verifikasi dosis dengan menggunakan perbandingan phantom standar dan phantom replika Ardian Handoko; Hidayatullah Hidayatullah; Eko Hidayanto; Very Richardina
Youngster Physics Journal Vol 7, No 1 (2018): Youngster Physics Journal Januari 2018
Publisher : Jurusan Fisika, Fakultas Sains dan Matematika, Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (583.794 KB)

Abstract

In the medical and radiology, phantom used as a simulator for the human body for radiotherapy activities. Most of them use homogeneous or standard phantom that have density same as water. This research was done because in real case, in the human body not only consists of soft tissue, but also there are other tissues such as lung and bone. By measuring using a non-homogeneous phantom or replica phantom with different materials densities, we compared the dose accuracy results from planning by this two phantom types. Replica phantom uses materials such as pine wood instead of lungs, polypropylene as a substitute for fat, acrylic instead of cartilage and solid silicon can change the bone. The study was conducted by varying the standard field area i.e., 3x3 cm, 5x5 cm, 10x10 cm, 15x15 cm, 20x20 cm and the mix area field. Obtained accurate results in standard phantom, i.e., 95.2%, 86.7%, 94.3%, 94.8%, 93.1% and 97.3%. Then on replica phantom accuracy is 94.7%, 95.6%, 96.2%, 86.0%, 91.6% and 96.6%. Keywords: Treatment planning system (TPS), Dose, Standard phantom, Non-homogeneous phantom, Replica phantom, Non-homogeneous tissue