Achmad Sjafei
Faculty of Dental Medicine, Universitas Airlangga, Surabaya

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Effects of strong bite force on the facial vertical dimension of pembarong performers C. Christina; Achmad Sjafei; Ida Bagus Narmada
Dental Journal (Majalah Kedokteran Gigi) Vol. 50 No. 2 (2017): June 2017
Publisher : Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (486.468 KB) | DOI: 10.20473/j.djmkg.v50.i2.p76-79

Abstract

Background: A pembarong performer is a reog dancer who bites on a piece of wood inserted into his/her mouth in order to support a 60 kg Barongan or Dadak Merak mask. The teeth supporting this large and heavy mask are directly affected, as the strong bite force exerted during a dance could affect their vertical and sagital facial dimensions. Purpose: This study aimed to examine the influence of the bite force of pembarong performers due to their vertical and sagital facial dimensions. Methods: The study reported here involved fifteen pembarong performers and thirteen individuals with normal occlusion (with specific criteria). The bite force of these subjects was measured with a dental prescale sensor during its centric occlusion. A cephalometric variation measurement was subsequently performed on all subjects with its effects on their vertical and sagital facial dimensions being measured. Results: The bite force value of the pembarong performers was 394.3816 ± 7.68787 Newtons, while the normal occlusion was 371.7784 ± 4.77791 Newtons. There was no correlation between the bite force and the facial sagital dimension of these subjects. However, a significant correlation did exist between bite force and lower facial height/total facial height (LFH/TFH) ratio (p = 0.013). Conversely, no significant correlation between bite force and posterior facial height/total facial height (PFH/TFH) ratio (p = 0.785) was detected. There was an inverse correlation between bite force and LFH/TFH ratio (r = -.464). Conclusion: Bite force is directly related to the decrease in LFH/TFH ratio. Occlusal pressure exerted by the posterior teeth on the alveolar bone may increase bone density at the endosteal surface of cortical bone.
The influence of artificial salivary pH on nickel ion release and the surface morphology of stainless steel bracket-nickel-titanium archwire combinations Ida Bagus Narmada; Natalya Tantri Sudarno; Achmad Sjafei; Yuli Setiyorini
Dental Journal (Majalah Kedokteran Gigi) Vol. 50 No. 2 (2017): June 2017
Publisher : Faculty of Dental Medicine, Universitas Airlangga https://fkg.unair.ac.id/en

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (777.547 KB) | DOI: 10.20473/j.djmkg.v50.i2.p80-85

Abstract

Background: In the oral cavity, orthodontic appliances come into contact with saliva which may cause corrosion capable of changing their surface morphology due to the release of metal ions. Surface roughness can influence the effectiveness of tooth movement. One of the ions possibly released when body fluid comes into contact with brackets and archwire is nickel ion (Ni). Ni, one of the most popular components of orthodontic appliances, is, however, a toxic element that could potentially increase the likelihood of health problems such as allergic responses during treatment. Purpose: The purpose of this study was to investigate the effect of different artificial salivary pH on the ions released and the surface morphology of stainless steel (SS) brackets-nickel-titanium (NiTi) and archwire combinations. Methods: Brackets and archwires were analyzed by an Energy Dispersive X-Ray Detector System (EDX) to determine their composition, while NiTi archwire compound was examined by means of X-ray Diffraction (XRD). The immersion test was performed at artificial salivary pH levels of 4.2; 6.5; and 7.6 at 37°C for 28 days. Ni ion release measurement was performed using an Atomic Absorption Spectroscopy (AAS). Surface morphology was analyzed by means of a Scanning Electron Microscopy (SEM). Results: The chemical composition of all orthodontic appliances contained Ni element. In addition, XRD was depicted phases not only NiTi but also Ni, Titanium, Silicon and Zinc Oleate. The immersion test showed that the highest release of Ni ions occured at a pH of 4.2, with no significant difference at various levels of pH (p=.092). There were surface morphology changes in the orthodontic appliances. It was revealed that at a pH of 4.2, the surfaces of orthodontic appliances become unhomogenous and rough compared to those at other pH concentrations. Conclusion: The reduction of pH in the artificial saliva increases the amount of released Ni ions, as well as causing changes to the surface morphology of brackets and archwires.