Zainul Muhlisin
Laboratorium Elektronika Dan Instrumentasi , Fisika FMIPA UNDIP

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Rekontruksi Citra Tomografi Sinar-X Flouresens 2D Berbasis Teknik Radiografi Digital Menggunakan Bahasa Pemrograman Matlab 7.1 M.Si, Sumariyah; Muhlisin, Zainul; Setiawati, Evi
BERKALA FISIKA Vol 13, No 4 (2010): Berkala Fisika
Publisher : BERKALA FISIKA

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (283.382 KB)

Abstract

This research has been done Recontructing of  2D X-ray Flouresense Tomographic Imaging Basis on Digital Radiograhy Technique using MATLAB 7.1 Programming  The research uses an unit Computed Radiografi, a rotated obyect and a reconstruction programme imaging. The shape of rotated object is prisma which made of acrylic, lenght 18 cm and  size sisi 6 cm. The prismacan  rotate continue and as cor of the rotatd obyek uss asylinder still. Recontruction 2D tomographic imaging build from 25 rotatd object radiograf imaging result of expose Computed Radiografi with expose factor constant ang interval increasing rotated angle7,50 . The reconstruction programme 2D Tomographic  consist of the cropping programme which produces  25 slice rotatd obyect forming sinogram and the programm Transformation invers Radon. The result of 2D Tomographic reconstruction in this rsearch obtain cross-sectionalprisma imaging is circle in the triangle sisi same imaging  which habrur.           Keywords: recontruction, tomography and radiography
The intensity of the magnetic field on different sex of fetus and accuracy of sex detection using gold ring pendulum Anwar, Mawakia; Samsudewa, Daud; Muhlisin, Zainul; Endrosuseno, Jatmiko
Livestock and Animal Research Vol 21, No 1 (2023): Livestock and Animal Research
Publisher : Universitas Sebelas Maret

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20961/lar.v21i1.59727

Abstract

Objective: This research aims to measure the intensity of magnetic field of different sex of fetuses and the accuracy of pendulum method for the sex detection of cow fetuses.Methods: Twenty-six Madura cows with gestational age of more than 4 months were used in this research. This research is composed of three steps : 1). Measuring the intensity of the magnetic field on the fetus using an Electromagnetic Field Meter (EMF) type 827 which is affixed to the right side of the abdomen 2). Observe the pattern of the gold ring pendulum used for sex detection of cow fetus 3). Measure the accuracy of the pendulum ring gold method. The data were analyzed using descriptive analysis.Results: The result of this research showed that the intensity of the magnetic field of a male fetus is 0.04 µT for a head, 0.07 µT for back, 0.05 µT for abdomen and 0.03 µT for tail. Magnetic field of a female fetus is 0.03 µT for head, 0.05 µT for back, 0.035 µT for abdomen and 0.01 µT for tail. The gold ring pendulum is a unidirectional pattern for detection male sex showed the accuracy of 91.67% and a rotating pattern for female fetuses showed accuracy of 85.71%. The average accuracy of detection using the gold ring pendulum is 88.46%.Conclusions: The conclusion of this research is male fetuses have a magnetic field higher than male fetus.