Chaterina Diyah Nanik Kusumawardani
Universitas Hang Tuah

Published : 4 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 4 Documents
Search

Pengaruh penambahan hidroksiapatit terhadap porositas dan compressive strength basis resin akrilik heat-curedEffect of hydroxyapatite addition towards porosity level and compressive strength of heat-cured acrylic resin base Chaterina Diyah Nanik Kusumawardani; Ronaldo Triputro Chondro; Ivan Andrian; Rima Parwati Sari
Jurnal Kedokteran Gigi Universitas Padjadjaran Vol 32, No 2 (2020): Agustus 2020
Publisher : Fakultas Kedokteran Gigi Universitas Padjadjaran

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24198/jkg.v32i2.26627

Abstract

Pendahuluan: Resin akrilik heat cured (HC) merupakan pilihan utama bahan sebagai basis gigi tiruan. Hidroksiapatit (HAP) adalah molekul kristalin yang sudah banyak digunakan di kedokteran gigi. Penelitian terdahulu membuktikan bahwa HAP mampu mengurangi monomer sisa pada resin akrilik HC, yang akan mengurangi juga porositas resin akrilik tersebut. Berkurangnya porositas resin akrilik, diharapkan akan meningkatkan kekuatan mekanik resin akrilik tersebut. Tujuan penelitian menganalisis pengaruh penambahan hidroksiapatit terhadap porositas dan compressive strength resin akrilik HC. Metode: Jenis penelitian eksperimental laboratoris. Sampel penelitian 20 resin akrilik HC berbentuk silindris (6x3mm), dibagi menjadi 4 kelompok. Kelompok kontrol (tanpa penambahan HAP), kelompok HAP 2%, kelompok HAP 5%, dan kelompok HAP 10%. Permukaan sampel diteliti menggunakan SEM untuk porositasnya. Penghitungan compressive strength sampel menggunakan Universal Testing Machine (load cell 300kg/mm2). Hasil: Uji one-way ANOVA dan Tukey-HSD menunjukkan perbedaan signifikan (p<0,05) antara kelompok kontrol (90±13,5MPa) dengan 5%HAP (105±4,3MPa) dan 10%HAP (113±10,2MPa), begitu pula antara 2%HAP (96±8,4MPa) dengan 10%HAP. Uji SEM menunjukkan tidak adanya reaksi kimia antara HAP dan resin akrilik HC. Tampak pula bercak putih tersebar tidak merata pada permukaan sampel akrilik di kelompok-kelompok perlakuan. Bercak putih ditemukan meningkat sebanding dengan peningkatan konsentrasi HAP, dengan diameter yang semakin besar. Simpulan: Penambahan HAP pada basis resin akrilik HC mampu menurunkan tingkat porositas dan meningkatkan nilai compressive strength. Penurunan tingkat porositas meningkat seiring dengan penambahan HAP. Compressive strength yang paling tinggi didapatkan pada basis resin akrilik heat cured dengan penambahan 10% hidroksiapatit.Kata kunci: Compressive strength, uji SEM, resin akrilik heat cured, hidroksiapatit. ABSTRACT Introduction: Heat-cured acrylic resin has been commonly used as a denture base, whereas hydroxyapatite (HAP) is a crystalline molecule widely used in the field of dentistry. Previous research has been proofed that HAP could reduce the residual monomer of heat-cured acrylic resin, which will reduce the porosity level in advance, so it was expected for better mechanical properties. This research was aimed to analyse the effect of HAP addition towards the porosity level and compressive strength of heat-cured acrylic resin. Methods: An experimental laboratory research was conducted towards 20 cylindrical samples (6 x 3 mm) of heat-cured acrylic resins, which were divided into four groups: Control group (without HAP addition), 2% HAP addition group, 5% HAP addition group, and 10% HAP addition group. Compressive strength was tested using Universal Testing Machine (load cell of 300kg / mm2). Each sample surface porosity was observed using the scanning electron microscope (SEM). Results: One-way ANOVA and Tukey-HSD tests results showed significant differences (p < 0.05) between compressive strength in the control group (90 ± 13.5 MPa) compared to 5% (105 ± 4.3 MPa) and 10% HAP addition group (113 ± 10.2 MPa), significant differences were also shown between the 2% (96±8.4MPa) and 10% HAP addition group. SEM imaging showed that there was no chemical reaction between HAP and heat-cured acrylic resin. It showed uneven white spots in acrylic sample’s surface in all treatment groups. Those white spots were likely to be found more in the higher concentration of HAP, so did the diameter of white spots was also found more in the higher concentration. Conclusion: The addition of hydroxyapatite to the base of heat-cured acrylic resin can reduce the level of porosity and increase the compressive strength value. The decrease in the porosity level increases with the addition of hydroxyapatite. The highest compressive strength is obtained with the addition of 10% hydroxyapatite.Keywords: Compressive strength, SEM imaging, heat-cured acrylic resin, hydroxyapatite.
In vitro study sargassum sp. effervescent towards antifungal and compressive strength silicone based softliner Chaterina Diyah Nanik Kusumawardani; Paulus Budi Teguh; I Gusti Made Oka Lestari; Meinar Nur Ashrin; Aulia Dwi Maharani; Arifzan Razak; Vivin Ariestania; Widaningsih Budiman; Rizko Wira Artha; Anindita Apsari
Odonto : Dental Journal Vol 9, No 2 (2022): December 2022
Publisher : Faculty of Dentistry, Universitas Islam Sultan Agung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30659/odj.9.2.299-309

Abstract

Background: Softliner is commonly used to provide convenience for edentulous patients. However, the use of softliner can cause denture stomatitis due to colonization of Candida albicans. Sargassum sp. contains active compounds of steroids, alkaloids, phenols, triterpenoids, act as antibacterial and antifungal. The use of Sargassum sp. in the form of effervescent as a denture cleanser can prevent denture stomatitis, and it’s expected not to affect the compressive strength. This study aimed to study the concentration variation of Sargassum sp. effervescent towards antifungal and compressive strength silicone based softlinerMethod: 20 sampels of silicone based softliner (10x3x2mm) divided into 5 groups. K(-) soaked in sterilled aquadest; K(+) in Polident solution; P1 in 10% effervescent Sargassum sp. solution; P2 20% ; P3 40%, for 15minutes. Candida calculated by colony counter (CFU/ml). Compressive strength measured by Universal Testing Machine.Result: Candida albicans in the K+ group is the lowest, while the K- group shows the highest value. In P1, P2, P3 group the value of Candida albicans is higher than K+ group, but much lower than K-. The compressive strength of K+ group shows the lowest value but in P3 group shows the highest value compared to other groups.Conclusion: The 10% concentration of effervescent extract Sargassum sp. is effective in reducing the number of Candida albicans in silicone based softliner compared to the K- group. The most effective concentration of effervescent extract Sargassum sp. in reducing the Candida albicans’ growth is 40%. The higher concentration of Sargassum sp. resulting in higher compressive strength.
PENGARUH LARUTAN KITOSAN SEBAGAI DENTURE CLEANSER TERHADAP KEKUATAN TRANSVERSA PADA PLAT AKRILIK, VALPLAST DAN LUCITONE-FRS Anindita Apsari; Chaterina Diyah Nanik Kusumawardhani
Jurnal Wiyata Penelitian Sains dan Kesehatan Vol 9, No 2 (2022)
Publisher : LP2M IIK (Lembaga Penelitian dan Pengabdian Masyarakat Institut Ilmu Kesehatan) Bhakti Wiy

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56710/wiyata.v9i2.621

Abstract

Latar belakang: Akrilik heat cured dan nilon termoplastik merk valplast dan lucitone-FRS adalah ketiga bahan yang paling sering digunakan sebagai basis gigi tiruan. Basis gigi tiruan harus memenuhi syarat kekuatan mekanis agar kuat menerima beban kunyah di dalam rongga mulut. Salah satu uji kekuatan mekanis adalah kekuatan transversa. Metode: 24 sampel plat akrilik heat cured, 24 sampel plat valplast, 24 sampel plat lucitone-FRS berukuran (10x10x2)mm dibagi 12 kelompok. Seluruh sampel direndam dalam aquadest sebagai kelompok kontrol, larutan polident sebagai kelompok kontrol positif, larutan kitosan 0,25% dan 0,5% dengan waktu perendaman 12 hari. Hasil: Uji Kruskall Wallis menunjukkan adanya perbedaan signifikan (p<0,05) pada seluruh kelompok perlakuan. Mann-Whitney menunjukkan adanya perbedaan bermakna (p<0,05) pada seluruh kelompok pada penelitian. Kesimpulan : Uji kekuatan transversa plat akrilik heat cured dan nilon termoplastik valpast dan lucitone-FRS tidak dapat dibandingkan karena saat uji kekuatan transversa, plat akrilik sampai patah, sedangkan plat nilon termoplastik valplast dan lucitone-FRS hanya melengkung.
In vitro study sargassum sp. effervescent towards antifungal and compressive strength silicone based softliner Chaterina Diyah Nanik Kusumawardani; Paulus Budi Teguh; I Gusti Made Oka Lestari; Meinar Nur Ashrin; Aulia Dwi Maharani; Arifzan Razak; Vivin Ariestania; Widaningsih Budiman; Rizko Wira Artha; Anindita Apsari
Odonto : Dental Journal Vol 9, No 2 (2022): December 2022
Publisher : Faculty of Dentistry, Universitas Islam Sultan Agung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (664.1 KB) | DOI: 10.30659/odj.9.2.299-309

Abstract

Background: Softliner is commonly used to provide convenience for edentulous patients. However, the use of softliner can cause denture stomatitis due to colonization of Candida albicans. Sargassum sp. contains active compounds of steroids, alkaloids, phenols, triterpenoids, act as antibacterial and antifungal. The use of Sargassum sp. in the form of effervescent as a denture cleanser can prevent denture stomatitis, and it’s expected not to affect the compressive strength. This study aimed to study the concentration variation of Sargassum sp. effervescent towards antifungal and compressive strength silicone based softlinerMethod: 20 sampels of silicone based softliner (10x3x2mm) divided into 5 groups. K(-) soaked in sterilled aquadest; K(+) in Polident solution; P1 in 10% effervescent Sargassum sp. solution; P2 20% ; P3 40%, for 15minutes. Candida calculated by colony counter (CFU/ml). Compressive strength measured by Universal Testing Machine.Result: Candida albicans in the K+ group is the lowest, while the K- group shows the highest value. In P1, P2, P3 group the value of Candida albicans is higher than K+ group, but much lower than K-. The compressive strength of K+ group shows the lowest value but in P3 group shows the highest value compared to other groups.Conclusion: The 10% concentration of effervescent extract Sargassum sp. is effective in reducing the number of Candida albicans in silicone based softliner compared to the K- group. The most effective concentration of effervescent extract Sargassum sp. in reducing the Candida albicans’ growth is 40%. The higher concentration of Sargassum sp. resulting in higher compressive strength.