Claim Missing Document
Check
Articles

Found 2 Documents
Search

Simulasi Relokasi Distribusi Jaringan Listrik Tegangan Rendah Menggunakan Simulated Annealing Abraham Latumahina
ARIKA Vol 5 No 1 (2011)
Publisher : Industrial Engineering Study Program, Pattimura University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (351.416 KB)

Abstract

Application electric poweris either requirement people in now days. The requirement electric power use in hawse until at industrial. 1here is network system a certain make special for user electric, form make electric power talk abaut case network in order to people for can use necessity That problem before by contractor side in building one electric distribution circuit there was one to pass as to interfal circuit that slim to .find obstacle, to consider light for mentioned activity there was one to use with one algorithm logic ( Algorithm Simulated Annealing ) that can to coma and to consider light for to peg out one distribution electric circuit. Simulated annealig can problem that to stand hefor to answer, because to put for to connect with can short -line to find that area, town, line to the amount collect jiff distribution circuit.
PENGEMBANGAN SISTEM KONTROL KUALITAS AIR UNTUK PEMBIBITAN IKAN PADA BALAI PERIKANAN BUDIDAYA LAUT AMBON Abraham Latumahina
Jurnal ELKO (Elektrikal dan Komputer) Vol. 7 No. 1 (2026): Jurnal Elko
Publisher : Politeknik Negeri Ambon

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54463/d9trzv02

Abstract

In fish breeding activities, water quality is a very crucial factor. Water parameters such as temperature, pH, conductivity for the survival of fish seeds. Conductivity is the value of water's ability to conduct electric current. The results measured are, temperature 25°C-35°C and pH 7.5-8.3. For fish cultivation, good water quality is the main key to the success of fish seeds. If the temperature and water tank containing fish exceeds 35°C, it means the water temperature in the tank has been declared hot, and that is certainly not good for the health of the fish so the water pump in the tank must be on to circulate the water temperature in the tank. Then if the pH in the tank exceeds 8.3, it means the water condition is not good for the health of the fish so the pump is on to drain the water in the tank and refill it when it is stable with this water quality control system, users are more facilitated to monitor the temperature and pH in the water quality control system more easily and efficiently.   Keywords: Design and Construction. Single Phase Motor