Claim Missing Document
Check
Articles

Found 3 Documents
Search

PEMBUATAN SISTEM INFORMASI AKADEMIK BERBASIS WEB PADA SEKOLAH DASAR HATI KUDUS Anthony Gunawan; Tony Tony; Desi Arisandi
Jurnal Ilmu Komputer dan Sistem Informasi Vol 3, No 1 (2015): Jurnal Ilmu Komputer dan Sistem Informasi
Publisher : Fakultas Teknologi Informasi Universitas Tarumanagara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24912/jiksi.v3i1.3261

Abstract

Sekolah Dasar Hati Kudus adalah salah satu sekolah dasar swasta yang terletak di perumahan Jelambar. Saat ini SD Hati Kudus masih menggunakan buku besar dan Microsoft Excel sebagai media penyimpanan data dan pengolahan data nilai. Penyampaian informasi masih menggunakan selebaran kertas yang diberikan satu per satu untuk siswa SD Hati Kudus. Hal ini dapat menimbulkan berbagai kendala antara lain seperti halnya pemrosesan data akademik membutuhkan waktu yang lebih lama dan sulit untuk mendapatkan data yang akurat. Metode yang digunakan dalam perancangan aplikasi ini adalah metode System Development Life Cycle (SDLC). Sistem ini memiliki 5 modul utama, yaitu: modul admin, modul siswa, modul guru, modul orangtua dan modul pengunjung. Sistem informasi akademik ini mengelola dan menampilkan data seperti : ujian sekolah, jadwal sekolah, informasi nilai dan informasi rapor. Dengan dibuatnya program aplikasi sistem informasi akademik ini diharapkan dapat mempermudah pekerjaan guru dalam memasukkan data nilai siswa dan rapor, informasi akademik lebih cepat diterima oleh guru, siswa dan orangtua, serta program aplikasi ini dapat mempermudah orangtua untuk memantau perkembangan nilai dan rapor anaknya.
Review & Penyesuaian SOP di PT Inserasena oleh Departemen Export Import Persiapan Menuju ke Perusahaan Penerima Fasilitas Kawasan Berikat Anthony Gunawan; Jani Rahardjo
Jurnal Titra Vol 11, No 2 (2023): Jurnal Titra 11(2) Juli 2023
Publisher : Jurnal Titra

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Market conditions are constantly changing, PT Inserasena plans to switch to becoming a company receiving Bonded Zone facilities from the previous KITE (Kemudahan Impor tujuan Ekspor) Return. The purpose of this transition is to maximize profits by accelerating cash flow and increasing production. Therefore, this study aims to prepare for the transition and fulfillment of the requirements by the provisions in bonded zones. This research was carried out by reviewing, brainstorming, and repairing and adjusting the Company's Internal Control System / Standard Operating Procedures related to the flow of goods in and out to fulfill the provisions in the Bonded Zone accompanied by the Export and Import Department. Based on the research results it is known that there are several SOPs documented in the ISO 9001: 2015 documentthat has not been updated with the actual work process, out of a total of 59 SOPs after adjustments, additions and reductions to 64 SOPs that are by Bonded Zone requirements and have been verified & validation with related departments and for departmental SOPs that experience significant adjustments are the Export-Import Department.
Common Mistakes in Execution of Plane Load Test Anthony Gunawan
Indonesian Geotechnical Journal Vol. 2 No. 2 (2023): Vol.2 , No.2, Agustus 2023
Publisher : Himpunan Ahli Teknik Tanah Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56144/igj.v2i2.53

Abstract

Shallow foundation is the preferred foundation whenever possible, as it is economically more feasible compared to deep foundation. The design method for shallow foundation has long been established by Terzaghi. The Terzaghi’s bearing capacity equation requires soil strength parameters for its calculation. To obtain accurate results, undisturbed sample for laboratory testing is necessary. However, depending on the accuracy of soil sampling and laboratory testing, the results can have large inaccuracy. The in-situ determination of shallow foundation can be carried out by plate loading test. It is a well-established test which was standardized by British Standards in 1990 and American Society for Testing and Materials in 1994. The testing method is simple, and the standards provide flexibility in the execution of the test. Unfortunately, this flexibility can cause mistakes in the execution of the test, as practitioners can be selective in choosing the test procedure to minimize the test duration and/or cost. These mistakes can cause the plate load test results to be unusable or lead to erroneous results. This paper aims to address common mistakes in execution of plate load test.