Bogie Frame Structure Evaluation for Light-Rail Transit (LRT) Train: A Static Testing Djoko Wahyu Karmiadji; Budi Haryanto; Ogi Ivano; Mustasyar Perkasa; Abdul Rohman Farid
Automotive Experiences Vol 4 No 1 (2021)
Publisher : Automotive Laboratory of Universitas Muhammadiyah Magelang in collaboration with Association of Indonesian Vocational Educators (AIVE)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (827.007 KB) | DOI: 10.31603/ae.4252

Abstract

A new bogie frame of Light-Rail Transit (LRT) is having its strength of structure verified with experimental static testing according to EN 13749 standards. Static testing of bogie frame structure of LRT is performed by using a combination of seven tensile and compression loads that comprise of operational loads (normal service) and over-loads (exceptional service). Measurement parameters of bogie frame are strain and deflection values. The strain and deflection values resulted at every step of the load test were measured and monitored to further be used as analytic data. This data is then compared to the stress data of finite element analysis to check its deviation value. Testing results show the maximum stress value is 81.48 MPa on operational load, meanwhile, for exceptional load case, maximum stress is 120.96 MPa and deflection value is 1.25 mm. The maximum stress value is still below yield strength of bogie frame material S 555J2 (y=355 MPa). According to testing data, structure of bogie frame LRT fulfill as the acceptance criteria.
Verification of urban light rail transit (LRT) bogie frame structure design lifetime under variable fatigue loads Djoko Wahyu Karmiadji; Budi Haryanto; Anwar Anwar; Budi Prasetyo; Yudi Irawadi; Abdul Rohman Farid; Isach W.Z. Karmiadji; Hijaz Ahmad
Mechanical Engineering for Society and Industry Vol 2 No 1 (2022)
Publisher : Universitas Muhammadiyah Magelang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31603/mesi.6938

Abstract

The bogie frame is the main structure of the train that supports the train's loads during its operation. These structures are subject to fatigue testing to ensure their design life is up to the required standards. The urban light rail transit (LRT) bogie frame used in the Greater Jakarta area is newly designed and manufactured by a commercial railway rolling stock manufacturer. The design lifetime of this newly designed bogie frame structure under various fatigue load conditions is verified experimentally by fatigue testing. Testing and evaluations were conducted following the EN 13749 standard and VDV recommendation. The fatigue test of the urban LRT bogie frame structure was carried out in the test hall of the BPPT Structural Strength Technology Center (B2TKS) using a combination of seven loadings. The bogie frame was subjected to two variable types of fatigue loads, namely driving in curves and passing points (switches), with 2,000,000 cycles, 4,000,000 cycles, and 6,000,000 cycles of fatigue loadings. The parameter measured on the bogie frame structure is the strain value during the test using a dynamic data logger. The stress values analyzed are the average stress and the stress amplitude and then plotted on the maximum and minimum stress curve. The bogie structure is inspected by the non-destructive test method in all areas of its welded joints. This inspection is carried out before and after the test to ensure whether there are cracks caused by fatigue loads. The results of the fatigue test on the bogie structure under the variable fatigue load conditions show that the maximum stress value of 91.71 MPa at 1,500,000 cycles, that occurs during the test, does not exceed the fatigue limit of the material, and there are no cracks in the structure after the test is carried out for up to 6,000,000 cycles.