This Author published in this journals
All Journal Mesin
Nathanael P Tandian
Unknown Affiliation

Published : 1 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search

PENERAPAN MODEL UP WIND, EKSPONENSIAL, DAN CENTRAL DIFFERENCE PADA METODA ANALISA SUB BULUH Nathanael P Tandian; Aryadi Suwono; Winarto Winarto
Mesin Vol. 18 No. 2 (2003)
Publisher : Mesin

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Sub-channel analysis is a method for analyzing thermal hydraulic aspects of nuclear reactors or heat exchangers. The analysis calculates distributions of fluid temperature, pressure, axial velocity, transverse velocity, and fuel rod temperature or heat flux. This paper deals with efforts for improving the accuracy of the sub-channel method. Three numerical schemes for evaluating transversal advective heat rates, i.e.: up wind, exponential, and central difference schemes, were compared. The differences among calculation results obtained by programs that apply these schemes were insignificant. The paper also seeks the best definition of averaged temperature for evaluating physical properties of control volume. It was found that accuracy of the sub-channel method can be improved if the volume-averaged and area-averaged enthalpy in the energy equation, and the volume-averaged density in the axial momentum equation were evaluated based on the fluid temperatures at the middle of control volumes.