Claim Missing Document
Check
Articles

Found 3 Documents
Search

Pengaruh Pemasangan Peredam Getaran Eksternal Tipe Viscous terhadap Kinerja Struktur Gedung Laode Azan Muzahab
Jurnal Teknik: Media Pengembangan Ilmu dan Aplikasi Teknik Vol 17 No 1 (2018): Jurnal Teknik - Media Pengembangan Ilmu dan Aplikasi Teknik
Publisher : Fakultas Teknik - Universitas Jenderal Achmad Yani

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26874/jt.vol17no1.59

Abstract

Selama ini, energi getaran gempa yang besar pada struktur gedung diatasi secara konvensional dengan meningkatkan kekuatan, kekakuan dan kapasitas deformasi in-elastik terhadap persyaratan keamanan beban dengan mengkombinasikan komponen struktur seperti dinding geser (shear walls), braced frames, kerangka penahan momen, diafragma dan rangka batang horisontal. Saat ini telah dikembangkan metode baru untuk mengatasi energi getaran gempa yang besar dengan cara memasang peredam getaran eksternal. Terdapat beberapa tipe peredam getaran eksternal salah satunya Bracing Viscous Damper. Peredam ini akan mendisipasi energi gempa yang masuk ke dalam struktur. Energi yang terdisipasi selanjutnya akan mempengaruhi respon dan kinerja struktur gedung. Penelitian ini akan mengkaji pengaruh peredam getaran eksternal tipe Bracing Viscous Damper terhadap respon dan kinerja struktur gedung menggunakan analisis Nonlinier Pushover yang evaluasi kinerjanya merujuk pada SNI 03-1726-2012, ATC-40, dan FEMA-273. Hasil analisis diperoleh: (1) Peredam eksternal mereduksi besar simpangan lateral sebesar 9.58% dan simpangan time history struktur gedung sebesar 58%, (2) Mereduksi Story Driff sebesar 22.9%, (3) Mereduksi gaya geser tingkat (Shear Story) sebesar 53.5%. Kinerja struktur gedung ber-peredam lebih baik jika dibanding tanpa peredam, hal ini tercermin dari titik kinerja struktur (Performance Point) yang diperoleh dari analisis Pushover. Berdasarkan batas kinerja menurut ATC-40 struktur ber-peredam masuk pada level Immediate Occupancy (IO) dan tanpa peredam masuk pada level Demage Control.
Effect of the Addition of Sikacrete-W and Viscocrete-3115n on the Compressive Strength of Concrete in Waterlogged Bore Pile Casting Work Abun Bunjamin; Ayu Ningrum Pertiwi; Elpan Yudiana; Muhammad Makkih; Laode Azan Muzahab
Journal of Social Research Vol. 4 No. 8 (2025): Journal of Social Research
Publisher : International Journal Labs

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55324/josr.v4i7.2693

Abstract

This study examines the effect of the addition of Sikacrete-W and Viscocrete-3115N additives on the compressive strength of concrete in waterlogged bore pile casting work. Concrete is an important construction material, but underground casting can lead to washout and segregation, which negatively impacts concrete quality. In this study, variations of Sikacrete-W addition of 3%, 5%, and 10% and 0.6% Viscocrete-3115N were used to improve the cohesion and viscosity of the mixture. The test results showed that the average compressive strength of concrete with the addition of additives was lower than that of normal concrete, with the largest decrease occurring in the 10% Sikacrete-W mixture. Meanwhile, a 5% Sikacrete-W mixture yielded an optimal compressive strength of 31.74 MPa, suggesting that the addition of additives could affect the characteristics of concrete under special conditions.
Peran Viskos Damper pada Struktur Gedung dengan Denah Beraturan dan Tak Beraturan Terhadap Beban Gempa Laode Azan Muzahab; Muhammad Rizky Zulkarnaen; Muhamad Ghulam Fafaro; Yando Rolan Sipayung; Darma Putra Andika Pratama
Jurnal Impresi Indonesia Vol. 4 No. 8 (2025): Jurnal Impresi Indonesia
Publisher : Riviera Publishing

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58344/jii.v4i8.6893

Abstract

Penelitian ini bertujuan untuk mengevaluasi efektivitas penggunaan fluid viscous damper (FVD) dalam meningkatkan kinerja seismik struktur gedung pada denah beraturan dan tidak beraturan. Dua model gedung beton bertulang enam lantai dimodelkan menggunakan perangkat lunak analisis dan desain struktur berdasarkan SNI 1726:2019 dan SNI 2847:2019. Analisis beban gempa dengan metode Respon Spektrum. FVD dipasang pada sisi luar setinggi gedung di kedua arah sumbu bangunan. Parameter yang diamati meliputi simpangan antar lantai (interstory drift), perpindahan lateral (story displacement), gaya geser tingkat (story shear), dan gaya geser dasar (base shear) dan kapasitas struktur terhadap beban gempa. Hasil analisis menunjukkan bahwa penggunaan FVD mampu mereduksi respons seismik secara signifikan pada kedua tipe gedung. Gedung beraturan menunjukkan distribusi beban yang lebih stabil, sedangkan gedung tidak beraturan memperoleh peningkatan performa yang lebih signifikan dengan FVD. Selain itu, kapasitas struktur meningkat setelah pemasangan FVD, yang menunjukkan kemampuan struktur menyerap energi lebih besar sebelum mengalami kerusakan plastis. Oleh karena itu, FVD direkomendasikan sebagai solusi efektif dalam desain maupun retrofit bangunan tahan gempa.