EFFECT OF MAGNETIC FIELDS ON SELECTED PARAMETERS IN SEWAGE S Johan
Purifikasi Vol 5 No 3 (2004): Jurnal Purifikasi
Publisher : Department of Environmental Engineering-Faculty of Civil, Environmental and Geo Engineering. Institut Teknologi Sepuluh Nopember, Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (188.441 KB) | DOI: 10.12962/j25983806.v5.i3.317

Abstract

Experimental design with a magnetic strength of 0.55 Tesla, a flow rate of 1.84 ml/s, 6 paired of non parallel magnets, with pH less than 7 showed that the concentrations of BOD, NH3-N, COD and SS were decreased up to three times using the settling test compared to typical treatment. The percentage of SS removal was 85.40 compared to 29.92 with-out magnet, so as BOD was 41.54 compared to 17.54, COD was 43.43 compared to 25.26 and NH3-N was 60.99 com-pared to 27.15 without magnet. This study concluded that magnetic technology had the potential to be used to further increase the efficiency of domestic sewage treatment by increasing the removal of suspended particles.