Sulardi Sulardi
Sekolah Tinggi Teknologi Minyak dan Gas Bumi (STT Migas) Balikpapan

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

HAZARD IDENTIFICATION AND PREVENTION METHODS ON WORK IN CONFINED SPACES Sulardi Sulardi; Nuruddin Kafy El-Ridho
IDENTIFIKASI Vol 5 No 2 (2019): IDENTIFIKASI
Publisher : Program Studi D-IV K3

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The purpose of this study is to provide an overview of potential hazards and safe work procedures in the confined space area of ​​the working of the oil and gas industry. The research method used was the application research method with a case study approach in the oil and gas industry in Balikpapan. The results showed that the potential danger in the room was limited by the danger of lack of oxygen, fire, poisoning explosion, irritation, static electricity, mechanical energy, extreme room temperature, dehydration, insufficient air circulation, slippery surfaces and ergonomic hazards. Safe working procedures in confined spaces were ensuring a safe working environment, use of PPE and work safety equipment, isolation of mechanical equipment, cleaning of gases and liquids, adequate air ventilation and adequate communication systems. The results of the study also recommended supporting the success of work in the confined space area to always be aware of the possibility of toxic gas, low oxygen concentrations and excess, the danger of work equipment and workers equipped with a gas tester.
PROTEKSI PASIF KEBAKARAN PADA STUKTUR PENOPANG PIPA PROSES DENGAN EPOXY INTUMESCENT Sulardi Sulardi
IDENTIFIKASI Vol 6 No 1 (2020): IDENTIFIKASI
Publisher : Program Studi D-IV K3

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36277/identifikasi.v6i1.115

Abstract

The purpose of this study is to provide a description of passive fire protection material specifications that are suitable and suitable for pipe rack protection, pipe support and hanger pipe support hotline hydrocarbons and working methods of application of epoxy intumescent material. The research method used is the applied research method with a case study approach to the difficulty of handling sub-standard conditions at the Balikpapan I refinery. The research was conducted for 6 months and an observation period of 2 years. The results showed that the epoxy intumescent material specifications could be applied well and safely with an application thickness of 8.13 mm for a 1.5-hour fire rating according to API Standard 2218 and covered insurance findings at the Balikpapan refinery 1. The success of the intumescent epoxy application replaced the fireproofing material based on cementitious this can be replicated to overcome similar problems at other process unit refineries that experience similar problems.