A COMPARISON OF THE FLEXURE BEHAVIOR OF NORMAL CONCRETE BEAM COMPILED BY GRAVEL AND CRUSHED STONE Samuel Layang; Wiratno
BALANGA: Jurnal Pendidikan Teknologi dan Kejuruan Vol. 1 No. 1 (2013): Journal Balanga Edisi Januari-Juni 2013
Publisher : Jurusan Pendidikan Teknologi dan Kejuruan, FKIP, Universitas Palangkaraya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This research purposed fordiscoverfigure of concrete beam flexure failure. Its concrete beams researched are composed by coarse grain aggregate of gravel and crushed stone. This research was conducted by 10 (ten) concrete cylinders (Ø15 cm x 30 cm) and 5 (five) concrete beams(60 cm x 15 cm x 15 cm). Normal concrete mix design is calculated by SNI 03-2834-2000 method.The result of this research has showed if average compressive strength of crushed stone concrete is 11.511 MPa and 12.449 MPa for gravel stoneconcrete. The average beam bending capacity of crushed stone concrete is 1.002kNm and 1.054 kNm for gravel stone concrete. The crack pattern of all tested beam considered similar. The crack occur was done in the middle of beam, moving by bottom to top which analogous to increasing load to the center of load. The failure of all tested beam are considered as flexure failure.
A STUDY TO HEALTH ASPECT OF THE BUILDING OF “PENDIDIKAN TEKNIK BANGUNAN FKIP PALANGKA RAYA UNIVERSITY” Wiratno
BALANGA: Jurnal Pendidikan Teknologi dan Kejuruan Vol. 2 No. 2 (2014): Journal Balanga Edisi Juli-Desember 2014
Publisher : Jurusan Pendidikan Teknologi dan Kejuruan, FKIP, Universitas Palangkaraya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This research objective is investigates health aspect of the building of Program Studi Pendidikan Teknik Bangunan, FKIP Universitas Palangka Raya according to Indonesian Article of Peraturan Menteri PU No. 29/PRT/M/2006 concerning Principal of the Technical Requirement of Civil Building. This research is arranged by main data which collected from field investigation. The main stages of this research consist of collecting data and processing. Data of physical building complete with facilities condition are compared to health aspect requirement by the required facilities by the Peraturan Menteri PU No. 29/PRT/M/2006. Based on its analysis result, the physical building complete with facilities condition have been not fully complying requirement of Peraturan Menteri PU No. 29/PRT/M/2006. There is 1 of 4 requirements of the health requirement not complying, especially sanitation requirement. It is important to renovate its building condition, especially sanitation installation. And the most important point to be arranged are a regularly maintenance to its building facilities.
THE OPTIMIZATION OF REINFORCING STEEL BY IRON FIBER (LATHE WASTE) AND OFFSET TECHNIQUE AT THREE-DIMENSIONAL PORTAL Samuel Layang; Wiratno
BALANGA: Jurnal Pendidikan Teknologi dan Kejuruan Vol. 3 No. 2 (2015): Journal Balanga Edisi Juli-Desember 2015
Publisher : Jurusan Pendidikan Teknologi dan Kejuruan, FKIP, Universitas Palangkaraya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The objective of this study is to determine the effect of metal fibres (lathe waste) usages and offset technique at three-dimensional portals to the reinforcement wide. The study was conducting by experimental in laboratory. This experiment is arranged by testing of 25 cylindrical concretes (size 15 cm x 30 cm) under mix design method of SNI 03-2834-2000 (The procedure of making a normal concrete mix plan). All concrete cylinders were tested at 28 days of age in order to obtain an actual compressive strength. The ultimate moment capacity of three-dimensional portal is analyzed by STAAD Pro 2004 engineering computer program. The results of test shows that the compressive strength on concrete with 8% steel fibres is increased up to 45.46%. And the reinforcement wide were decresing up to 1.87% (pedestal level 1); 2.95% (pedestal level 2); 2.67% (field level 1) and 3.99% (field level 2). The beams which only using the offset technique will save the use of steel amounted to 17.81% (pedestal level 1); 18.25% (pedestal level 2); 2.38% (field level 1) and 2.80% (field level 2). Beams that used iron fibres and the offset technique will save the use of steel amounted to 18.25% (pedestal level 1); 20.18% (pedestal level 2); 4.92% (field level 1) and 6.55% (field level 2). Its decresing wide was showing on statics analisys and caculation of reforcing steel requirement.
THE BENDING CAPACITY OF CONCRETE BEAM DUE TO ADDITION OF IRON FIBER (WASTE OF LATHE MACHINE) Samuel Layang; Wiratno
BALANGA: Jurnal Pendidikan Teknologi dan Kejuruan Vol. 4 No. 2 (2016): Journal Balanga Edisi Juli-Desember 2016
Publisher : Jurusan Pendidikan Teknologi dan Kejuruan, FKIP, Universitas Palangkaraya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This research aimed to determine the effect of iron fibers (waste of lathe machine) to the capacity of flexure in normal concrete mix. This research uses test specimen of 15 pieces cylindrical (size 15 cm x 30 cm) and 9 lengths of beam (length x width x height: 60 cm x 15 cm x 15 cm). Concrete mix are designed complying to SNI 03-2834-2000 on Procedures Mix Concrete Manufacturing Plan for Normal. Concrete cylinders were tested at 28 days to get the actual compressive strength. Concrete beams were tested based on ISO 4431:2011 test method for flexural strength of normal concrete by two point loading at 28 days to obtain a flexural strength, fracture patterns that occur. Based on the test results of concrete cylinders, the average value of compressive strength for each variation of the mixture is 14.58 MPa (fiber content 0%); 10.80 MPa (fiber content 8%); 13.60 MPa (the fiber content of 10%). Flexure testing results for each variation of the mixture was 1.87 MPa (fiber content 0%); 1.64 MPa (fiber content 8%); 1.78 MPa (fiber content 10%). The pattern of cracks that occur in all the beams show the same results that the crack caused by the bending effect. Cracks occurred in the middle of the beam span that starts from the bottom side experiencing gravity and move toward the top and finish with the breaking of the beam.
AN EFFORT TO PREVENT INCORRET PLN’S INVOICE FOR REGULAR CUSTOMERSHOUSING PURPOSE IN PALANGKA RAYA Wiratno
BALANGA: Jurnal Pendidikan Teknologi dan Kejuruan Vol. 6 No. 2 (2018): Journal Balanga Edisi Juli-Desember 2018
Publisher : Jurusan Pendidikan Teknologi dan Kejuruan, FKIP, Universitas Palangkaraya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This research conducted for discover caused factor of the incorrect invoice of PLN electric power consumption and any effort to minimize its incorrect invoice. The research was conducting at ten (10) random houses in Palangka Raya as its sample. All researched houses had inconvenience experience with PLN invoicing. The PLN clerks were complaining against access to records compsumtion gauge. It problem raised due to PLN terminal was fitting far away from the house bound. Its condition has been quite making bit difficult for PLN clerks to see visually. Its current situation expected to be improved by re-fitting the gauge to lookable, but safe. A full suppots of regular customers also be expected.
STUDY TO RIVER PORT FACILITIES OF TOURISM PURPOSE PALANGKA RAYA Wiratno; Samuel Layang
BALANGA: Jurnal Pendidikan Teknologi dan Kejuruan Vol. 1 No. 2 (2013): Journal Balanga Edisi Juli-Desember 2013
Publisher : Jurusan Pendidikan Teknologi dan Kejuruan, FKIP, Universitas Palangkaraya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This research objective is for investigates existing facilities of the River Port of Tourism Purpose, Palangka Raya according to Indonesian Article PP RI No. 61 / 2009 concerning Port. This research is arranged by main data collected from field investigation and secondary data from Dinas Perhubungan Provinsi Kalimantan Tengah (Board of Transportation Affair of The Central Kalimantan). The main stages in this research consist of data collecting and processing. Data of existing facilities are compared to required facilities by the PP RI No. 61/2009. Based on analysis result, the existing river port facilities have been not complying yet criteria of PP RI No. 61/2009 concerning Port. There were 14 of 26 requirements of the river port criteria not available or approximately more than 50% criteria uncomplying. It is important to renovate its river port facilities, especially to main facilities which connected to passenger security, safety and convenience. And the most important point to arrange are a regularly maintenance to its facilities.