Legia Prananto
Unknown Affiliation

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

DOSIS RADIASI LENSA MATA PADA PEMOTRETAN ORBITA POSTERO ANTERIOR (PA) AXIAL DAN PA AXIAL REVERSE Nursama Heru Apriantoro; Legia Prananto; Budi Setiawan
Prosiding Seminar Nasional Pakar Prosiding Seminar Nasional Pakar 2019 Buku I
Publisher : Lembaga Penelitian Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25105/pakar.v0i0.4146

Abstract

Penelitian ini bertujuan untuk mendapatkan kriteria gambar serta dosis serap radiasi  pada orbita dengan posisi PA dan reverse PA.  Penelitian dilakukan di Laboratorium Teknik Radiodiagnostik dan Radioterapi Politeknik Kesehatan Jakarta II dan laboratorium PTKMR–BATAN.  Dosis serap pada penelitian ini menggunakan TLD yang terbuat dari bahan LiF buatan Harshaw, USA. Hasil penelitian mendapatkan nilai rata-rata dosis serap pada lensa mata dengan posisi PA axial dan PA Axial Reverse masing-masing  0,027 mGy dan 0,041 mGy.  Nilai rata-rata dosis efektif tahunan masih dibawah batas ambang yang direkomendasikan ICRP maupun BAPETEN yaitu 15 mSv per tahun.
Analysis of the Use of Sequence T2 SPACE Dark Fluid in MRI Brain Coronal Slice Examinations with Clinical Epilepsy at the National Brain Center Hospital Legia Prananto; Khairil Anwar; Riska Sekar Febriani
WMJ (Warmadewa Medical Journal) Vol 8 No 2 (2023): November 2023
Publisher : Warmadewa University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22225/wmj.8.2.7776.64-68

Abstract

This research centers on Brain MRI examinations in patients with clinical epilepsy, featuring the incorporation of an additional T2 SPACE dark fluid sequence. Brain MRI examination with clinical epilepsy at National Brain Center Hospital is a frequent examination. Epilepsy is such a condition characterized by recurrent seizures caused by disturbances in the brain function. In relation to which, this research aims to analyze the use of dark fluid T2 SPACE sequences and analyze the results of MRI images on dark fluid T2 SPACE sequences for information on coronal MRI Brain anatomical images with clinical epilepsy at National Brain Center Hospital. As for the research design used was descriptive qualitative with a case study approach which was conducted starting from February up to May 2023 at National Brain Center Hospital using a Siemens Skyra MRI aircraft with a power of 3 Tesla. The populations of this research were the patients who had clinical Temporal Lobe Epilepsy (TLE) and the number of samples was 10 patients. The result of this study indicates that the use of the T2 SPACE dark fluid sequence produces more detailed images of the hippocampal structure in terms of slices. In addition, it provides good spatial resolution for assessing the hippocampal structure, allowing the visualization of abnormal signal intensities within the hippocampus, and facilitating the detection of hippocampal abnormalities. Therefore, it can be concluded that the use of T2 SPACE dark fluid sequence is very important and considerably quite informative in diagnosing epilepsy cases.