Performance Comparison of Pure and Modified Sine Wave Inverters in an Off-Grid PV System Nelly Safitri; Rudi Syahputra; Supri Hardi; Saifuddin Muhammad Jalil
Aviation Electronics, Information Technology, Telecommunications, Electricals, and Controls (AVITEC) Vol 8, No 1 (2026): February
Publisher : Institut Teknologi Dirgantara Adisutjipto

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.28989/avitec.v8i1.3810

Abstract

This study evaluates the performance of Pure Sine Wave (PSW) and Modified Sine Wave (MSW) inverters within small-scale off-grid solar power generation systems. The assessment was conducted utilizing a 160 Wp monocrystalline solar panel, a 10 A solar charge controller (SCC), a 12.8 V–100 Ah lithium iron phosphate (LiFePO₄) battery, along with both 500 W PSW and MSW inverters, across varying panel tilt angles ranging from 45°-165°. The findings indicated that the PSW inverter delivered a more consistent output voltage between 221 and 222 V, exhibiting minimal fluctuation of ±1 V and low harmonic distortion at 2.5%. The MSW inverter produced an output voltage between 222 and 225.5 V, characterized by greater variability and higher harmonic distortion under both light and heavy load conditions. The analysis of the solar photovoltaic (PV) system provides critical insights into the performance differences between the two inverter types. Notably, the results related to tilt angle are not merely supplementary; they serve as indicators of varying irradiance conditions, enabling a more comprehensive evaluation of inverter performance concerning fluctuations in input power levels. Both PSW and MSW inverters achieved an efficiency rating of 85%, ensuring stable and smooth outputs. However, with regard to long-term reliability, the PSW inverter significantly surpasses its counterpart, rendering it a more appropriate choice for permanent solar PV installations. As the results, the PSW inverter is particularly suited for sensitive loads that demand high power quality, while the MSW inverter remains viable for less demanding applications when the cost is considered.
Sistem Pengendali Tegangan pada Generator Induksi 3 Phasa Menggunakan Kontrol PI Said Abubakar; Supri Hardi; Rizal Alfayumi
JET (Journal of Electrical Technology) Vol 2, No 3 (2017): JET Edisi Oktober
Publisher : Universitas Islam Sumatera Utara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30743/jet.v2i3.234

Abstract

Pada umumnya Pembangkit Listrik Tenaga Mikrohidro (PLTMh) banyak memanfaatkan motor induksi sebagai generator induksi karena cukup menggunakan energi terbarukan seperti air dan angin sebagai penggerak (Prime over) dan tidak banyak membutuhkan perawatan. Permasalahan generator induksi adalah apabila dibebani tegangannnya akan turun dan apabila terjadi pengurangan beban, maka tegangan akan naik. Tujuan penelitian ini adalah menstabilkan tegangan pada generator induksi 3 phasa 1 Kw 4 kutub menggunakan kontrol PI dengan cara menentukan parameter dan respon yang tepat. Metode yang digunakan dalam penelitian ini adalah metode pengujian dan pengukuran untuk mendapatkan parameter kendali Kp dan Ti berdasarkan metode Ziegler-Nichols. Hasil pengujian dengan mentuning kurva S didapat nilai Tu = 0,3 detik dan Tg = 2 detik serta parameter Kp = 6 dan Ti = 0,99. Respon kendali penstabil tegangan maksimal 25 detik dengan penambahan dan pengurangan beban sebesar 60 Watt. Tegangan stabil 200 VAC, frekuensi 50 Hz, dan kecepatan generator konstan 1538 Rpm.