Claim Missing Document
Check
Articles

Found 2 Documents
Search

Perencanaan Instalasi Pengolahan Air Limbah Mal X Kota Bandung Gita Ayu Rahmawati; Eka Wardhani; Lina Apriyanti
Jurnal Serambi Engineering Vol 4, No 2 (2019)
Publisher : Fakultas Teknik

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32672/jse.v4i2.1330

Abstract

Waste Water Treatment Plant (WWTP) in the shopping center is planned to cater for its constantly changing concept. The centre was to initially provide electronic services, however, it is currently providing food and beverage services. The changes will affect the amount of wastewater and the characteristics produced. Wastewater discharge is calculated from 80% of the 83.73m  of clean water needed per day. The concentration of the wastewater characteristics obtained for parameters BOD, COD, TSS, oil and fat were 182.67 mg/l, 328.50 mg/l, 255.92 mg/l, 47.93 mg/l respectively. The selection of the processing alternatives is based on the descriptive method which uses a series of selected alternative unit screens, grease traps, equalization tanks, activated sludge, settling tanks and chlorination. The dimensions of the processing unit are calculated based on the selected alternatives. And the land requirements needed to build a WWTP at X Mall amounts to 80m2
Pengelolaan Limbah B3 Di Rumah Sakit X Kota Batam Salma Savira Siddik; Eka Wardhani
Jurnal Serambi Engineering Vol 5, No 1 (2020)
Publisher : Fakultas Teknik

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32672/jse.v5i1.1602

Abstract

Hospital X was class b private hospitals that are located in Batam with 297 unit beds. The waste that can be categorized as solid waste medical in the hospital which is infectious, pharmacy, hazardous and toxic waste, cytotoxic, sharp object.  The purpose of this research is to identify, a source of , the characteristics, solid waste medical produced by hospital X in Batam and also conduct an evaluation of solid waste medical management hospital in accordance with the minister of environment and forestry 56 2015 on procedures and technical requirements of hazardous and toxic waste management than health service facilities. This research used primary and secondary data collection method. The research results show solid waste medical management at the hospital X in Batam most of them are in according to rule. But there are some things that must be improved are blinding trash bag, efficiency and minimal temparature the combustion chamber incinerator. Management efforts must to do are briefing to officer of the waste collection about the way to blinding trash bag in according to the regulation and the incinerator that can serve confirming to standard of burning hazardous and toxic waste.