Efzah Efzah
Divisi PulmonologiAlergi dan lmunologi Departemen llmu Penyakit Dalam Fakultas Kedokteran-Universitas Sumatera Utara (FKUSU) Rurnah Sakit Umum Pusat (RSUP) Haji Adam Malik Medan

Published : 1 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search

Hubungan antara Asthma Control Test (ACT) dengan spirometri sebagai alat pengukur tingkat kontrol asma Efzah Efzah; Zuhrial Zubir
Majalah Kedokteran Nusantara The Journal Of Medical School Vol 50, No 1 (2017): The Journal of Medical School
Publisher : Fakultas Kedokteran USU

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Introduction :Asthma is a chronic respiratory disease that still a serious health problem worldwide. IIis nown that there is no cure for asthma, but tile disease can be c:ontrolled in some pati1:m.k;l111rn:1 t;u11lrulis fucuses on the adequacy therapy. GINA guideline for theassessment of asthma control using gauges lung ruriction, but this evaluation is difficult because of lack of facilities spir:imetry as a measure of lung function in primary care.Asthma control tool that is simple,efficient, easy and necessary for asthma patients. Asthma Control Test (ACT)is a screening test In the form :if a questionnaire :in a clinical assessment of patients withasthma. Method : This study wa cross se·::tionalstudy,in 61 patients with asthma were taken by consecutive samplin£. The whole subject of study conduct ACT questionnaire and splrometry followed by examination. The analysis data using the ROC curve for diagnostic value and Pearson correlation test. Result :61 subjects,39 ternale and 22 male subjects with a mean age of 54.44 yea•s. Based on thevalue of the subject ACT consists of 31.1% is well controllec, partly controlled 21.3% and 47.5"/, is not controlled. AC r cutoff values •'3f•'3fbased on ttiose receiver operating characteristic (ROC) to distinguishbetween normaland FEV1 <80% was 21.5 with 71.4% sensitivity and 96.3% specificity. By using the Pearson correlation test founo a significant ccrrelation between the ACT with FEV1 (p <0.001), showed modera:e positive correlatic•n (r= 0.5li3). Conclusion : There is a significart relationship between asthma controltest (ACT) with spirometry with moderate positive correlation. So that ACT can be used to assess asthma control in health facilities were spirometry not availab'e. Keyword: asthma bronchial, level of asthma i:ontrol, asthma confrol test (ACT), spirometry