Balamuralikrishnan R.
Asst. professor, Department of BNE, College of Engineering, National University of Science and Technology, Muscat, PO Box:2322, CPO Seeb 111,

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Study on Retrofitting of RC Column Using Ferrocement Full and Strip Wrapping Balamuralikrishnan R.; M. Al Madhani; R. Al Madhani
Civil Engineering Journal Vol 5, No 11 (2019): November
Publisher : Salehan Institute of Higher Education

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.28991/cej-2019-03091425

Abstract

Ferrocement is one of the cement-based composites used for retrofitting and rehabilitation among many applications. Ferrocement is one of the reinforced concrete form with lightweight and thin composite with durability and environmental resistant that strengthen the conventional RC columns to increase its strength and serviceability. This paper examines the performance of the ferrocement wrapping in RC columns experimentally with numerical simulation using ANSYS19. Totally sixteen number of RC column of size 150 mm × 150 mm in cross section and 450 mm in length were cast and tested in laboratory. Twelve are retrofitted columns with respect to volume fraction and wrapping technique. Six columns were retrofitted by full wrapping technique and six columns of strip wrapping technique. The remaining four columns are control columns in virgin condition to compare with the retrofitted columns. Concerning the volume fraction of each specimen, the number of pre-woven mesh layers were single layer, double layer and three layers. C30 concrete grade adopted in all specimens as per ACI Committee 211-1.91 with 4H8 longitudinal reinforcement and H6 of 75mm c/c ties. As the previous researchers examined the ferrocement and proved its efficiency. This study aims to examine the ferrocement in full and strip wrapping technique to compare their efficiency to increase the strength. Finite element analysis using ANSYS19 adopted to compare the experimental data with the numerical simulation. The results are analyzed and observed that the ferrocement has increased the confinement and strength of the RC columns. 
Comparative Study on Two Storey Car Showroom Using Pre-engineered Building (PEB) Concept Based on British Standards and Euro Code Balamuralikrishnan R.; Ibrahim Shabbir Mohammedali
Civil Engineering Journal Vol 5, No 4 (2019): April
Publisher : Salehan Institute of Higher Education

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (920.422 KB) | DOI: 10.28991/cej-2019-03091296

Abstract

Majority of steel structures are used for low-rise single storey buildings mainly for industrial purpose. Steel structures are preferred for industrial buildings due to its higher strength to weight ratio as compare to RCC structures and steel structures also gives more free internal space by allowing long clear span between columns. Pre-engineered building (PEB) is a modern age concept of utilizing structural steel and optimizing the design by ensuring the economical integrity of the structure. The structural members are designed and fabricated in the factory under controlled environment to produce optimum sections by varying the thickness of the sections along the length of the member as per the bending moment requirement. The aim of the research paper is to analyses and design a PEB car showroom of two storey (G+1) using STAAD Pro in accordance to British standards (BS 5950-1:2000) and Euro codes (EC3 EN-1993-1) with wind and seismic analysis. In order to achieve the above aim of the project, two models of the car showroom were created namely British Standard (BS) model and Euro code (EC) model using STAAD Pro. The member property for BS model is assigned with tapered frame sections while the EC model is assigned with universal standard section frames. The load cases were assigned to the models for analysis include dead load, live load, wind load and seismic load. Wind load and seismic load being the critical dynamic loads that will be analyzed for the stability of the structure against lateral forces. The results from the analysis and design of the two models were within the allowable limits for ultimate and serviceability limit state since the internal stresses in all the members satisfies the unity check ratio requirements for both design codes. The dynamic analysis results suggest that EC model has higher resistance to seismic loading as compare to BS model since the maximum displacement with time in X-direction for EC model is 8.83 mm and for BS model is 10.5 mm. The total weight of the structure for BS model is 1125.431 kN and for EC model is 1214.315 kN, which makes EC model 7.9% heavier than BS model. Moreover, the total weight of all the portal frames for BS model is 457.26 kN and for EC model is 574.725 kN, which makes tapered frame sections to utilize and reduce the amount of steel by 25.7%. Therefore, BS model proved to be an economical model when compared to Euro code.