R Arif Wibowo
Department Of Physics, Faculty Of Science And Technology, Universitas Airlangga

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

The Effective Dose Analysis of Head CT-Scan on Adult Patients Febriana Dwi Rahmadani; R Arif Wibowo; Khusnul Ain
Indonesian Applied Physics Letters Vol. 2 No. 1 (2021): June
Publisher : Universitas Airlangga

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20473/iapl.v2i1.28300

Abstract

This study was aimed to determine the difference of the effective dose from the clinical and theoretical on the head CT-Scan examination of adult patients and compare the data with the permitted dose limit from BAPETEN. The data collected at Haji Hospital Surabaya using MSCT Siemens Somatom Definition AS 64 Slice on five adult patients, aged between 28-67 years old. The step before the scanning process were adjusting the voltage (kV) and current values (mA) on the CT-Scan. The scanning duration for each patient was 4s and resulted in head images with CTDIvol and DLP values displayed on the monitor screen. The effective dose limit value for the head CT scan was 2.8 mSv, according to BAPETEN. The study results showed that the effective dose on head CT Scan examination was below the safe dose limit value, while the different fractions between the clinical and theoretical of Patient A, B, C, D, and E was 4.11%; 5.46%; 6.19%; 6.52%; and 5.42%, respectively.
MRI Cervical Image Analysis with Fat Suppression Techniques Between Sequent Turbo Invers Recovery Magnitude (TIRM) and Fat Saturations (Fat Sat) on Degenerative Disc Disease at Haji Hospital Surabaya Vita Arinda Ayu Putri Nata; Suryani Dyah Astuti; R. Arif Wibowo
Indonesian Applied Physics Letters Vol. 2 No. 1 (2021): June
Publisher : Universitas Airlangga

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20473/iapl.v2i1.28301

Abstract

This study aimed to analyze the difference of image information and determine the better image quality between the Turbo Invers Recovery Magnitude (TIRM) and Fat Saturation (Fat Sat) techniques on cervical MRI examination at Haji Hospital Surabaya. The samples of this study were one female and three male patients. The obtained data were ROI of the vertebral body tissue, intervertebral discs, spinal cord, and then calculated as SNR and CNR values. SNR and CNR values were statistically tested using Paired T-Test on SPSS 2.5. The Paired T-Test results showed a significant difference between the TIRM and Fat Sat techniques, p>0.05. SNR and CNR average values also proved that the Fat Sat technique had more optimal image quality than the TIRM technique.