Teuku Nanda Saifullah Sulaiman
Universitas Gadjah Mada

Published : 3 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 3 Documents
Search

Evaluation of Drug Storage Systems Based on Good Distribution Practice in Pharmaceutical Wholesalers in Indonesia: A Systematic Review Martsom Putra Sulung S Langga; Teuku Nanda Saifullah Sulaiman; Satibi
Jurnal FARMASIMED (JFM) Vol 8 No 2 (2026): Jurnal Farmasimed (JFM)
Publisher : Fakultas Farmasi Institut Kesehatan Medistra Lubuk Pakam

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35451/fnws3q19

Abstract

The pharmaceutical distribution system plays a crucial role in ensuring that medicines maintain their quality, safety, and efficacy throughout the supply chain. In Indonesia, Pharmaceutical Wholesalers (PBF) are required to implement Good Distribution Practice (CDOB), including proper storage systems; however, variations in compliance have been reported in several local studies. Purpose: This study aimed to identify the implementation of drug storage systems in PBF in Indonesia based on CDOB and to analyze the most frequent areas of non-compliance. Methods: A systematic review was conducted following PRISMA 2020 guidelines. Literature searches were performed in Google Scholar and Semantic Scholar for studies published between 2014 and 2024. Primary observational descriptive studies focusing on drug storage practices in Indonesian PBF were included, and seven eligible articles were analyzed. Result: The findings indicate that non-compliance most frequently occurs in the operational aspect, particularly in the inconsistent implementation of FEFO, medicines classification, and adherence to standard operating procedures. Issues related to building and equipment, such as unstable temperature control and inadequate ventilation, are also commonly reported. Weaknesses in documentation, stock verification, and managerial oversight further affect storage effectiveness. Conclusion: These recurring patterns suggest that challenges lie more in implementation consistency and internal control rather than regulatory absence. Overall, drug storage practices in Indonesian PBF generally refer to CDOB standards; however, compliance remains uneven. Strengthening operational discipline, documentation accuracy, and managerial supervision is essential to improve distribution quality and ensure patient safety.
PENGARUH KONSENTRASI DAN PEMBILASAN TERHADAP RETENSI RADIOAKTIVITAS IODIUM-131 CAIR PADA SYRINGE DALAM PENYIAPAN RADIOFARMAKA Anggoro Praja Mukti; Hilda Ismail; Teuku Nanda Saifullah Sulaiman; Akhmad Riski
Jurnal Ilmiah Ibnu Sina (JIIS): Ilmu Farmasi dan Kesehatan Vol 11 No 2 (2026): Jurnal Ilmiah Ibnu Sina
Publisher : Sekolah Tinggi Ilmu Kesehatan ISFI Banjarmasin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36387/jiis.v11i2.3047

Abstract

Radioactivity retention in syringes during the preparation of liquid Iodine-131 radiopharmaceuticals may potentially reduce the prepared activity, cause radioactive contamination, decrease imaging quality, increase radioactive waste, and contribute to unwanted radiation exposure. This study aimed to evaluate the effects of concentration and rinsing on radioactivity retention of liquid Iodine-131 in syringes. An experimental study was conducted using liquid Iodine-131 at concentrations of 5, 10, and 15 mCi/mL. Initial and residual activities in the syringe were measured using a dose calibrator, while radiation exposure rate was measured using a gamma survey meter. The rinsing test was performed at a concentration of 15 mCi/mL using water for injection (WFI) and 0.9% NaCl as rinsing solutions in three sequential rinsing steps. Radioactivity retention increased with increasing concentration, with values of 12.90 ± 0.63%, 17.45 ± 0.68%, and 20.97 ± 0.74% at concentrations of 5, 10, and 15 mCi/mL, respectively. Radiation exposure rate also increased significantly. Rinsing significantly reduced radioactivity retention, while the type of rinsing solution used showed no significant difference. Concentration and rinsing affected radioactivity retention of liquid Iodine-131 in syringes
Radioactivity Retention of Liquid Iodine-131 in Residual Syringes: Implications for Radiation Exposure and Radioactive Waste Management in Radiopharmaceutical Preparation Anggoro Praja Mukti; Hilda Ismail; Teuku Nanda Saifullah Sulaiman
Jurnal Sehat Indonesia (JUSINDO) Vol. 8 No. 2 (2026): Jurnal Sehat Indonesia (JUSINDO)
Publisher : CV. Publikasi Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59141/-.v8i2.561

Abstract

Residual radioactivity in syringes used during the preparation of liquid iodine-131 radiopharmaceuticals may contribute to avoidable radiation exposure and increase the radioactive waste burden. Although radioactivity retention in syringes has been reported for several radiopharmaceutical preparations, safety-oriented evaluations of residual iodine-131 activity in liquid formulations remain limited. This study aimed to investigate the relationship between residual radioactivity retention and radiation exposure rates in syringes following liquid iodine-131 preparation and to assess the implications for radioactive waste management. This experimental study used sodium iodide labeled with iodine-131 (Na¹³¹I) in liquid form. Initial and residual syringe activities were measured using a radionuclide dose calibrator, while ambient dose equivalent rates were measured using a gamma radiation survey meter. Residual activity, percentage radioactivity retention, radiation dose rate, and estimated decay-in-storage duration were analyzed descriptively. Pearson's correlation analysis and simple linear regression were performed to evaluate the relationship between radioactivity retention and measured radiation dose rates. Sequential rinsing with water for injection and 0.9% sodium chloride solution was evaluated as an approach to reducing residual radioactivity. Mean residual syringe activity increased from 0.270 ± 0.012 mCi at an initial activity concentration of 5 mCi/mL to 0.435 ± 0.016 mCi at 15 mCi/mL. Radioactivity retention increased from 12.90 ± 0.63% to 20.97 ± 0.74%, accompanied by an increase in the measured radiation dose rate from 2.703 ± 0.102 to 4.131 ± 0.237 µSv/h. Radioactivity retention exhibited a strong positive correlation with the radiation dose rate (Pearson's r = 0.9412, R² = 0.8858, p < 0.0001). Sequential rinsing reduced the measured dose rate from 4.160 ± 0.186 to 1.329 ± 0.034 µSv/h using water for injection and from 4.190 ± 0.117 to 1.314 ± 0.023 µSv/h using 0.9% sodium chloride solution. These findings demonstrate a strong association between residual syringe radioactivity and measured radiation dose rates following liquid iodine-131 preparation, highlighting the contribution of residual activity to the initial radioactive waste burden. Controlled rinsing procedures may help reduce residual syringe activity and support radiation protection, contamination control, and radioactive waste management practices in nuclear medicine facilities.