Claim Missing Document
Check
Articles

Found 1 Documents
Search

Pengaruh Variasi Durasi Waktu Injeksi Oksigen Terhadap Performansi Insinerator Dual Chamber Limbah Medis Darma, I Wayan Arya; Winaya, I Nyoman Suprapta; Pratama, I Putu Angga Yuda; Sanatana, I Ketut Sakya
Rekayasa Material, Manufaktur dan Energi Vol 8, No 2: JULI 2025
Publisher : Fakultas Teknik UMSU

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30596/rmme.v8i2.24923

Abstract

Incineration is an effective waste processing method, especially for medical waste which is B3 waste. The high temperature combustion process in incineration is expected to be able to reduce medical waste optimally. However, emissions produced during the incineration process can pollute the surrounding environment and harm health. So it is necessary to develop incineration methods to reduce exhaust emissions but still be able to reduce medical waste optimally. In this research, additional oxygen injection was carried out in chamber 2 of the dual chamber medical waste incinerator by varying the duration of the oxygen injection time with the aim of obtaining optimal performance and reducing the resulting exhaust emissions. The research was carried out using medical waste weighing 1 kg with variations in the duration of oxygen injection, 2, 3 and 4 minutes. The research results show that increasing the duration of oxygen injection time can increase combustion efficiency, increase the temperature in chamber 2 and reduce the resulting exhaust gas emissions.