RANCANG BANGUN VOLTMETER EKONOMIS BERBASIS ANDROID DENGAN KALIBRASI OPEN CIRCUIT VOLTAGE DENGAN METODE MOVING AVERAGE UNTUK APLIKASI SISTEM MONITORING BATERAI PADA KENDARAAN ELEKTRIK Elroy FKP Tarigan; Leo Setiawan; Andreas Edi
Technologic Vol 13, No 1 (2022): TECHNOLOGIC
Publisher : Politeknik Astra

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.52453/t.v13i1.402

Abstract

Salah satu perangkat yang sering digunakan dalam sistem monitoring baterai untuk mobil listrik adalah voltmeter, fungsi dari Voltmeter untuk mebaca nilai tegangan pada saat baterai tidak terhubung dengan beban (Open Circuit Voltage), dengan voltmeter nilai tegangan baterai dapat dipantau, dalam perancangannya pembacaan voltase baterai ditargetkan dapat mendekati perangakat dengan standar industry. Salah satu metode untuk meningkatkan kualitas dari voltmeter yaitu dengan metode kalibrasi yang sesuai, sehinga pembacaan voltase yang semula menunjukkan pergerakan nilai pembacaan yang tidak stabil dapat lebih stabil dan nilai hasil pembacaan dapat mendekati nilai dari alat dengan kualitas standar industri. Dengan metode kalibrasi hasil pembacaan voltase menjadi stabil dan nilai error sebesar 0,15 volt untuk rentang pembacaan 10 volt dan factor ekonomis perancangan alat sebesar 1:5
Electrical Performance Test Design for Speed Sensor Torque Flow, Rear Brake, and Solenoid ECMV Power Train  HD785-7 at PT XYZ Setia Abikusna; Diki Ramadhani; Leo Setiawan; Lukyawan Pama Deprian; Randy Putra Afani
Jurnal Asiimetrik: Jurnal Ilmiah Rekayasa Dan Inovasi Volume 7 Number 2 (2025)
Publisher : Fakultas Teknik Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/asiimetrik.v7i2.8613

Abstract

PT XYZ's Component Exchange (COMEX) Department has 8 Quality Assurance Processes, one of which is performance test (QA6). The performance test is conducted to evaluate the condition of overhauled components. From January to February 2024, the COMEX Department experienced issues with electrical components in the Power Train area, specifically the Electronic Control Modulating Valve (ECMV) solenoid, torque flow speed sensor, and rear brake speed sensor. Currently, the functional inspection tool for the solenoid only uses an Arduino as a power supply and an impact wrench as a substitute for the gear shaft to inspect the torque flow speed sensor and rear brake speed sensor. The results from these inspections are inaccurate, leading to rework on the transmission components and the brake final drive of the HD785-7. The 8-step method was used to address these issues. This method includes Determining Themes, Current Condition Analysis, Target Setting, Root Cause Analysis, Improvement Plan, Improvement Implementation, Result Evaluation, Standardization and Improvement Plan. Improvements included creating an electrical performance test tool, developing work instructions for using the tool, and establishing a reusable parts standard. The tool successfully reduced the rework of electrical parts, achieving a 100% reduction in rework from January-February 2024 to April-June 2024.