Distribution Factor Method Modified for Determine of Load Contribute based on the Power Factor in Transmission Line Syarifuddin Nojeng; Syamsir Syamsir; Arif Jaya; Andi Syarifuddin; Mohammad Yusri Hassan
Indonesian Journal of Electrical Engineering and Computer Science Vol 11, No 3: September 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v11.i3.pp1236-1242

Abstract

This paper proposes a modification of distribution factor methods for identifying the load contribute in a transmission open access, with regard to the load power factor. This method may be considered as the first pricing strategy to be proposed in bilateral transaction for transmission usage, based on the actual use of the transmission network. The merit of this method relies on the existence of a load power factor with GLDF  methods, which allocate the  transmission cost, not only based on the amount of power flow but also on the load characteristic. A case study utilizing the IEEE 30-bus system was conducted to illustrate the contribution of the proposed method in allocating the transmission usage to the user in a fair manner.
Impact of micro hydro power plants on transient stability for the micro grid 20 kV system Syarifuddin Nojeng; Syamsir Syamsir; Reny Murniati
Indonesian Journal of Electrical Engineering and Computer Science Vol 24, No 3: December 2021
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v24.i3.pp1278-1287

Abstract

Transient stability analysis is conducted to determine the ability of the electric power system in maintaining the operating stability after a major disturbance. The disturbance can be trigger an impact on the stability of the rotor angle, voltage, and system frequency which can cause loss of synchronization. In this paper, the impact of the interconnection of the Tombolo-Pao mini hydro power plant (MHPP) on the stability of the system was analyzed by several scenarios to determine the behavior of system parameters in a 20 kV system interconnection network. This research is an implementation of regulatory provisions relating to the study of the connection to the PLN distribution network through by regulator. Based on the result of simulation study, transient stability of generators at TomboloPao power plant about 0.1 second, will not occur with network configuration according to modeling activation of anti-islanding protection of Tombolo Pao Power Plant which is set by 2 second. The simulation results show that the location of the disturbance in the electric power system has been influenced by the behavior of the power plant (synchronous generator) which can lead to the instability of the micro-hydro connected to the micro-grid system 20 kV.