Liu Chao
Wuhan University

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Analysis of Weak Position in Overhead line under Heavy Icing Condition by Finite Element Method Gan Yan; Liu Chao; Ruan Jiangjun; Li Jinliang; Du Zhiye; Hu Yuanchao
Indonesian Journal of Electrical Engineering and Computer Science Vol 12, No 7: July 2014
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v12.i7.pp5011-5021

Abstract

Transmission tower is an important component of power system, and heavy iced transmission line has became one of the important factors against its safety and stability in China's power system these years but the transmission line designed from traditional standard can't endure the more worse environment. In this paper, for positioning the weak points of the transmission line under heavy icing accurately and providing accurate positional parameters to online monitoring devices, the strain section model is built to analysis their mechanical properties under icing and wind conditions .In proposed method, the coupling effect between tower and lines is considered, then the weak tower is picked out by strain section model that is combined with eight towers. The single one-tower-two-lines model of weak tower is built to simulate and verify the weak point accurately. Finally the better way is defined to get the location of weak structure combined with the advantages of both models.
Effect of Contamination on Electric Field Distribution of DC Voltage Divider Caibo Liao; Ruan Jiangjun; Du Zhiye; Liu Chao
Indonesian Journal of Electrical Engineering and Computer Science Vol 12, No 7: July 2014
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v12.i7.pp5071-5077

Abstract

In order to research the influence of the contamination around the external insulating surface of DC voltage divider with different types in the electic field distribution by using the finite element method, a two dimensional axisymmetric model of the DC voltage divider in Longquan convertor station is built. Through the calculation comparison in electrostatic and quasi-electrostatic field, the relative dielectric constant of the dry, moist and the non-uniform mixed contamination layer is discussed under the condition of the material parameters is known in quasi-electrostatic field .Analysis shows that for dry contamination,the field type has no influence on the electric field distribution when the parameters of the materials are same. While for moist contamination,the relative dielectric constant in electrostatic field should be set according to the material resistivity in quasi-electrostatic field and the actual condition. The calculation of the non-uniform contamination prove that the materials parameters in electrostatic filed is reasonable.