A Novel Traveling Wave Based Differential Protection for Distributed Parameter Line Baina He; Yunwei Zhao; Hengxu Ha
Indonesian Journal of Electrical Engineering and Computer Science Vol 11, No 9: September 2013
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Traditional current differential protection is based on Kirchhoff’s Law, certainly is severely influenced by the distributed capacitance current. A new traveling wave based differential protective principle is proposed by employing the characteristics of current traveling waves for the distributed parameter line model. There are fixed propagation relations between traveling waves of terminals as the line is healthy or the fault is external, however, the relationship is broken for the internal faults. The protective criterion and scheme are established by this character. The key technique is to quickly calculate the propagating traveling waves from the other terminal on line. The coefficients of propagation function from one terminal to another are obtained by using orthogonal projection methods. The principle and algorithm need not high sampling frequency, are adaptive for not only fundamental component but the transient components, as well as is not sensitive to setting parameters. The large amounts of ATP simulation tests show that the protective scheme and algorithm is simple with high reliability, security, speedy and sensitivity. DOI: http://dx.doi.org/10.11591/telkomnika.v11i9.3254 
Research of Bipolar HVDC Transmission Lines Based on Traveling Wave Differential Protection Baina He; Yunwei Zhao; Hengxu Ha
Indonesian Journal of Electrical Engineering and Computer Science Vol 11, No 12: December 2013
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The principle of the traveling wave based differential protection for bipolar HVDC transmission lines is proposed in the paper. Unlike the traditional current differential protection, the quantity of current is replaced by the quantity of the traveling wave for comparison. The traveling wave at the remote end is transferred to the local end for comparison to the local traveling wave. For the bipolar DC transmission lines, the polar-mode (aerial mode) traveling waves are employed to establish the discriminative criterion. The ground-mode traveling waves are utilized for faulty line detector for bipolar operation modes. The entire protection scheme is simulated in PSCAD/EMTDC associated with the standard ±500kV HVDC transmission system. The simulation results show that the new protection has the advantages of higher sensitivity, reliability and security. The fault resistance can be coverd by the traveling wave based differential protection reaches to 500 Ohm.  DOI: http://dx.doi.org/10.11591/telkomnika.v11i12.3700 
The Research of Secondary Arc Spectrum Characteristics on UHV Baina He; Yunwei Zhao
Indonesian Journal of Electrical Engineering and Computer Science Vol 10, No 6: October 2012
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

On UHV power transmission lines, when single-phase ground fault happen, it will appear secondary arc on lines, the existence of secondary arc impact on the stable operation of system. The effectiveness of single-pole autoreclosure (SPAR) in maintaining power system stability is largely determined by the speed with which secondary arc extinction, and hence autoreclosure, can be achieved. The paper adopts total harmonic distortion (THD) to judge the status of arc. First, the simulation model of secondary arc is established by ATP software. Then, faulted phase voltage and secondary arc are simulated in different close angle. Last, spectrum characteristics and harmonic content of faulted phase voltage and current are analyzed in different close angle, at the same time, THD of non-faulted phase is also analyzed by Fourier algorithm. Through the fault phase voltage and current simulation and Fourier analysis, which comes to the conclusion that at the peak in the power supply voltage secondary arc is the most difficult to extinguish and the harm to insulation is the greatest. DOI: http://dx.doi.org/10.11591/telkomnika.v10i6.1411
The Research of Digital Algorithm Based on Frequency-Dependent Transmission Lines Yongqing Liu; Baina He; Yunwei Zhao; Hengxu Ha; Xinhui Zhang
Indonesian Journal of Electrical Engineering and Computer Science Vol 11, No 5: May 2013
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The algorithm for obtaining the discrete response of popagation function for frequency dependent parameter line is presented. Consider a minimum sampling period Tsm, that is, the highest frequency fH=1/(2Tsm) in the signal is taken into account. The impedance z(w) and the admittance y(w) are obtained in the frequency range of [0,fH] by employing the Carson’s formula. The propagation function at each frequency point is subsequently obtained, the impulse response in discrete time domain is then obtained using Poision Sum Formula. In order to avoid the long length of impulse reponse under the higher sampling frequency, the poles and zeros of z transform of discrete propagation function are evaluated by the Prony’s method. Subsequently, the coeffcients of the discrete infinite impulse response of propagation function are obtained. Using these coefficients the wave transfer sources can be easily computed by discrete convolution operation. The simulation tests show that the results using the propsed method is accurate, the error is not more than 1% in contrast of the results generated by EMTP. DOI: http://dx.doi.org/10.11591/telkomnika.v11i5.2491