Classification of Partial Discharge Sources using Statistical Approach L. W. Ren; M. S. Abd Rahman; A. Mohd Ariffin
Indonesian Journal of Electrical Engineering and Computer Science Vol 6, No 3: June 2017
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v6.i3.pp537-543

Abstract

In high-voltage (HV) power equipment, degradation of insulation has been main concern for protection of equipment. This is due to occurrence of partial discharges (PD) activity within HV insulating systems which can be initiated from different types of local internal or external defects. Thus, partial discharge (PD) identification and classification are important for diagnostic insulation systems problems in order to ensure maintenance process can be carried out effectively and hence improve reliability and durable operation of HV equipment. In this work, the relation of the observable statistical characteristics from PD data with the characteristic of the defect is an important factor to determine the defect inside insulation system. Ultimately, the statistical parameters obtained from PD data can be used to classify different PD sources occur inside HV insulation system. Thus, the objective of this paper is to produce a unique pattern according to discharge source using statistical method. Several statistical parameters such as mean, variance, standard deviation, skewness and kurtosis have been used and analysed.
Partial discharge detection device using ultrasonic sensor on medium voltage XLPE cable I. F Radzi; N H Nik; N Rameli; A. Mohd Ariffin; M. S. Abd Rahman; M. R Rahman; M. R Ahmad; A. S Salleh
Indonesian Journal of Electrical Engineering and Computer Science Vol 17, No 2: February 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v17.i2.pp886-894

Abstract

There are many methods that have been studied by earlier researchers in order to detect the acoustic properties of Partial Discharge (PD) emitted by PD sources. One of the methods known as ultrasonic sensing on medium voltage Cross-Linked Polyethylene (XLPE) cable was adopted to detect partial discharges on commercial applications, usually by using Acoustic Emission (AE) sensors. This paper presents the processes of designing a PD sensor to detect the acoustic properties of the partial discharges on medium voltage XLPE cable. This PD sensor method works by detecting the partial discharges occurred at the joint of the cable which can act as an early warning device to help minimize the repair and maintenance costs of degrading cable. Result of the experiment shows the complete design of the prototype device, the device after fabrication and the functionality of the device. This design of the prototype can be beneficial for future uses in designing cost efficient and smaller sized PD detection devices. By positioning the sensor in horizontal position directly to the source of PD on the cable, the sensor will be able to detect acoustic properties of PD, by picking up the frequencies beyond 40 kHz. By varying the voltage applied values, a design of experiment (DOE) is carried out accordingly. Result of the experiment shows that the prototype device is functioning as expected, and hence this finding will be very useful to the consumers of power industries as the sensor device can serve as an alternative device to the commercialized PD sensing devices which are bulky and expensive.