Hua Wang
Unknown Affiliation

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Graphs obtained from collections of blocks Colton Magnant; Pouria Salehi Nowbandegani; Hua Wang
Electronic Journal of Graph Theory and Applications (EJGTA) Vol 3, No 1 (2015): Electronic Journal of Graph Theory and Applications
Publisher : GTA Research Group, Univ. Newcastle, Indonesian Combinatorics Society and ITB

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.5614/ejgta.2015.3.1.6

Abstract

Given a collection of $d$-dimensional rectangular solids called blocks, no two of which sharing interior points, construct a block graph by adding a vertex for each block and an edge if the faces of the two corresponding blocks intersect nontrivially.  It is known that if $d \geq 3$, such block graphs can have arbitrarily large chromatic number.  We prove that the chromatic number can be bounded with only a mild restriction on the sizes of the blocks.  We also show that block graphs of block configurations arising from partitions of $d$-dimensional hypercubes into sub-hypercubes are at least $d$-connected.  Bounds on the diameter and the hamiltonicity of such block graphs are also discussed.
Voltage Deviation in Breaker-testing Station Study Using ADPSS Zhenan Zhang; Hua Wang; Qionglin Li; Xiaomeng Li
Indonesian Journal of Electrical Engineering and Computer Science Vol 12, No 5: May 2014
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

With the fast development of China power grid, more and more power system devices such as breakers are applied. Breaker testing also becomes very important. At the same time the testing procedure will cause voltage deviation around the breaker-testing station. Big voltage deviation can make severe damage for the power customers. Based on the power system simulation software ADPSS developed by China Electric Power Research Institute (CEPRI), this paper built up the simulation model using the electromechanical-electromagnetic transient hybrid method, and simulated the voltage deviation in a Henan breaker-testing station. The simulation results showed that with the higher testing breaker current level, bigger voltage deviation is caused. Finally this paper suggested a testing breaker current level for the breaker-testing station with Power Quality Criteria. DOI : http://dx.doi.org/10.11591/telkomnika.v12i5.5101