Studi evaluasi Pencahayaan Alami Pada Gedung Kuliah Bersama Iii Universitas Muhammadiyah Malang Gw, Ode Rapija; ., Beta Suryo Kusumo
Media Teknik Sipil Vol 9, No 1 (2011): Februari
Publisher : Department of Civil Engineering, Faculty of Engineering, University of Muhammadiyah Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (936.186 KB) | DOI: 10.22219/jmts.v9i1.1115

Abstract

In Gedung Kuliah Bersama (GKB) III at University Muhammadiyah of Malang, at the first floor with a low-level of illumination should be used for audio-visual rooms or meeting, or it’s not used to read, write a long time (often), and for a thorough job, so it does not require a high level of illumination, because the majority of rooms on the first floor level of 30 lux illumination only and the maximum light level is only about 300 lux at the window. On the second floor with office functions majors and computer labs are appropriate to the level of illumination most of the rooms reached 200 lux, at the window level to 500 lux maximum lighting. Lecture room on 3 and 4 floors have a very high level of illumination, on the third floor reached 120-240 lux in the most of the rooms and around the window to 1200 lux, the uneven illumination very disturbing visual comfort of user room. On the fourth floor most of the rooms have lighting levels of 200-400 lux and 1800 lux maximum reached around the windows.Key Words: Lighting levels or level of illumination, GKB ( Gedung Kuliah Bersama )
STUDI KEBUTUHAN BUKAAN PADA BANGUNAN PERUMAHAN TYPE MENENGAH DENGAN PENDEKATAN PENCAHAYAAN GW, Ode Rapija
Media Teknik Sipil Vol 10, No 1 (2012): Februari
Publisher : Department of Civil Engineering, Faculty of Engineering, University of Muhammadiyah Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (304.169 KB) | DOI: 10.22219/jmts.v10i1.1212

Abstract

The purpose of the light on the environment is to lightening every element of the buildingwhich makes the clearer visual sence. In addition, the presence of the light is hoped to comfort theperson who lives there which their activities. The building on medium size (type 45 and type 54)has the small window. Moreover, the building placed on the block only has the front window. Itcauses the building on medium size will catch less light, the room will be darker, and the lamp willbe turned on the day.The instrument of this research is a software dialux 4, 7. The advantages of using this softwaredialux 4, 7 are it will be easier and more variative in editing the geometry of the room, it will beeasier in inserting the furniture to the room which will be calculated, and the output can be conturgrid-3d.The size of the windows in the guestroom, the family room, and the diningroom of themedium building is about 4, 09- 5, 6 m2. The window in the main bedroom is about 1, 51-1, 96 m2width. The window in the children bedroom is about 1, 38-1, 64 m2 width.Keywords: window, lightening intensity.