Beton Fc’ 21,7 Mpa Menggunakan Agregat Kasar Biji Genitri Muhammad Sulton Bahrudin; Agata Iwan Candra; Sigit Winarto
Jurnal Manajemen Teknologi & Teknik Sipil Vol 3, No 2 (2020): OCTOBER
Publisher : Faculty of Engineering, Kadiri University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (614.471 KB) | DOI: 10.30737/jurmateks.v3i2.1135

Abstract

Concrete in technological development has progressed very rapidly, so that it is able to open ideas in the use of organic materials as an alternative material for concrete. Genitri seeds are an organic material that can be used as an alternative to the building blocks of concrete. Genitri seeds have very good hardness and have a light volume weight so that they can reduce the large structure weight due to the weight of the concrete itself. The research method used in this study is an experimental method with genitri seeds as a mixture of coarse aggregate in concrete. This study aims to determine how much influence the compressive strength, slump value, volume weight, absorption, using a mixture of genitri seeds with a percentage of 5%, 10%, 15% of the weight of coarse aggregate. The results showed that the highest compressive strength was obtained by the addition of 5% genitri seeds, namely 20.75Mpa with an average slump value of 5.2. In the absorption test, the value of ¼ hour 0.040 1 hour 0.022 4 hours 0.006 24 hours 0.002 was obtained.Beton dalam perkembangan teknologi mengalami kemajuan yang sagat pesat, sehingga mampu membuka pemikiran dalam pemanfaatan material organik sebagai bahan alternatif penyusun beton. Biji genitri merupakan salah satu bahan organik yang dapat digunakan sebagai alternatif material penyusun beton. Biji genitri memiliki kekerasan yang sangat baik dan memiliki berat volume yang ringan sehingga dapat mengurangi berat struktur yang besar akibat beban dari berat beton itu sendiri. Metode penelitian yang digunakan pada penelitian ini adalah metode eksperimental dengan biji genitri sebagai bahan campuran agregat kasar pada beton. Penelitian ini bertujuan untuk mengetahui seberapa besar pengaruh terhadap kuat tekan, nilai slump, berat volume, absorpsi, dengan menggunakan bahan campuran biji genitri dengan persentase 5%,10%,15% dari berat agregat kasar. Dari hasil penelitian menunjukkan bahwa kuat tekan tertinggi diperoleh dengan penambahan biji genitri sebesar 5% yaitu 20,75Mpa  dengan nilai slump rata-rata 5,2. Pada pengujian absorpsi diperoleh nilai ¼ jam 0,040 1 jam 0,022 4 jam 0,006 24 jam 0,002.
Pemanfaatan Limbah Galvalum Sebagai Substitusi Aggregat Kasar Pada Jobmix Beton Muhammad Bahrudin; Agata Iwan Candra; Sigit Winarto
Jurnal Manajemen Teknologi & Teknik Sipil Vol 3, No 2 (2020): OCTOBER
Publisher : Faculty of Engineering, Kadiri University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (658.674 KB) | DOI: 10.30737/jurmateks.v3i2.1152

Abstract

Concrete is one of the construction materials that is widely used. Currently, variations in concrete are being studied. Galvalum waste has high tensile properties but is mild. Its lightweight properties are expected to reduce the weight of the concrete itself. The purpose of this study is to find out the value of strong press, absorption, weight type (E), degree of saturation (Sr), moisture content (Wc), and porosity of the addition of galvalume waste. The method used is a experimental method. Variations in galvalum waste substitution used are 50% and 100% of the aggregate weight is roughT the sample used in the form of a cylinder size of 15cm x 30 cm with the initial quality of fc' 18.67 Mpa. The results of the strong press test showed that the galvalum waste subtitution has not been able to exceed the initial quality of the plan. The highest test result was obtained at a percentage of 50% with a strong press score of FC' 17.94 Mpa. In the percentage, absorption test results are 0.010%, the weight of the type is 2325 kg / m3, the pore number is 0.00232%, the water content is 0.108%, and porosity is 0.00108%.Beton merupakan salah satu bahan konstruksi yang banyak dipergunakan. Saat ini, pengguanaan variasi pada beton sedang banyak diteliti. Limbah galvalum memiliki sifat tarik yang tinggi namun ringan. Sifatnya yang ringan diharapkan mampu mengurangi berat beton itu sendiri. Tujuan dari penelitian ini adalah untuk mengetahui nilai kuat tekan, absorpsi, berat jenis (Ɣ), angka pori (e),derajat kejenuhan (Sr), kadar air (Wc), dan porositas dari penambahan limbah galvalum. Metode yang digunakan merupakan metode eksperimen. Variasi pensubtitusi limbah galvalum yang digunakan yaitu 50% dan 100% dari berat agregat kasar. sampel yang digunakan berbentuk silinder ukuran 15cm x 30 cm dengan mutu awal fc’ 18.67 Mpa. Hasil uji kuat tekan menunjukkan bahwa subtitusi limbah galvalum belum mampu melebihi mutu awal rencana. Hasil uji tertinggi didapat pada prosentase 50% dengan nilai kuat tekan fc’ 17,94 Mpa. Pada prosentase tersebut, didapat hasil uji absropsi yaitu 0,010%,  berat jenis yaitu 2325 kg/m3, angka pori yaitu 0,00232%, kadar air yaitu 0,108% serta porositas yaitu 0,00108%. 
Modifikasi Beton Fc 9,8 Mpa Menggunakan Abu Ampas Kopi Shirfi Wimaya; Ahmad Ridwan; Sigit Winarto
Jurnal Manajemen Teknologi & Teknik Sipil Vol 3, No 2 (2020): OCTOBER
Publisher : Faculty of Engineering, Kadiri University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1048.045 KB) | DOI: 10.30737/jurmateks.v3i2.1096

Abstract

Concrete is a construction material that is widely used in building structures. Cement is the main constituent of concrete whose needs are increasing. The expansion of coffee shops in Kediri City resulted in an increase in the volume of coffee grounds waste, which can be used as an alternative to cement. The purpose of this study was to determine the value of the slump test, compressive strength test, and test the absorption capacity of the addition of coffee grounds ash to the concrete sample specimen using a cylinder is measuring 15cm x 30cm with 5 pieces of concrete quality K-125 or equivalent to fc '9.8 Mpa. Slump test results with a percentage of 4%, 8%, 12%, namely 2.5 cm, 0.5 cm and 2.5 cm. The results of the concrete compressive strength test with a percentage of 4% obtained the results of the compressive strength fc '10.51 Mpa or equivalent to K125, a percentage of 8% produces a compressive strength of fc' 8.39 and a percentage of 12% produces a compressive strength fc '7.56 Mpa equivalent to K100. The water absorption test results for 28 days resulted in an average value of 0.32 kg, 0.25 kg, 0.15 kg, and 33 kg.Beton merupakan salah satu bahan konstruksi yang banyak digunakan pada struktur bangunan. Semen merupakan penyusun utama beton yang kebutuhannya semakin meningkat. Perluasan kedai kopi di Kota Kediri mengakibatkan peningkatan volume limbah ampas kopi yang dapat digunakan sebagai alternatif pengganti semen. Tujuan penelitian ini adalah untuk mengetahui nilai uji slump, uji kuat tekan, dan uji daya serap penambahan abu ampas kopi pada benda uji beton dengan menggunakan silinder berukuran 15cm x 30cm dengan kualitas beton sebanyak 5 buah. K-125 atau setara dengan fc '9.8 Mpa. Hasil uji slump dengan persentase 4%, 8%, 12% yaitu 2.5 cm, 0.5 cm dan 2.5 cm. Hasil uji kuat tekan beton dengan persentase 4% didapatkan hasil kuat tekan fc '10 .51 Mpa atau setara dengan K125 persentase 8% menghasilkan kuat tekan fc '8,39 dan persentase 12% menghasilkan kekuatan tekan fc '7,56 Mpa setara dengan K100. Hasil pengujian daya serap air selama 28 hari menghasilkan nilai rata-rata 0,32 kg, 0,25 kg, 0,15 kg, dan 33 kg.
Penerapan Metode CPM Dan PERT Pada Gedung Parkir 3 Lantai Grand Panglima Polim Kediri Tsalist Iluk; Ahmad Ridwan; Sigit Winarto
Jurnal Manajemen Teknologi & Teknik Sipil Vol 3, No 2 (2020): OCTOBER
Publisher : Faculty of Engineering, Kadiri University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (564.349 KB) | DOI: 10.30737/jurmateks.v3i2.1054

Abstract

The project is an activity carried out to products or services that have specific scheduling. Scheduling is determined by the relationship between activities made very detailed and accurate. Therefore, the purpose of the final task is to know how to implement the Critical Path Method (CPM) and Program Evaluation and Review Technique (PERT) in scheduling the project, which originally used the Bar Chart method with a duration of 140 days and resulted in a cost of Rp. 5.500.000.000. From the calculation result of this final task in using the CPM, the method generates a period of 105 days and provides cost after crashing in the labor increase of Rp. 5.568.464.052 and the increase in working hours (overtime) Rp. 5.603.725.490. While using the PERT method generates a period of 109 days and generates the cost after being crashing in the labor increase of Rp. 5.574.721.755 and the increase of working hours (overtime) of Rp.5.612.082.633 with a projected probability of reaching the target of 84 %. Has a comparison with the difference in cost of Rp. 6,257,703 in increased workforce and Rp. 8,357,143 other than working hours.Proyek merupakan suatu kegiatan yang dilakukan untuk menghasilkan produk / jasa yang mempunyai penjadwalan tertentu. Penjadwalan ditentukan oleh hubungan antar kegiatan yang dibuat sangat rinci dan akurat. Oleh karna itu tujuan dari artikel ilmiah ini adalah untuk mengetahui bagaimanakah penerapan metode Critical Path Method (CPM) dan Program Evaluation and Review Technique (PERT) pada penjadwalan proyek tersebut yang awalnya  menggunakan metode Bar Chart dengan durasi waktu 140 hari dan menghasilkan biaya sebesar Rp.5.500.000.000. Dari hasil perhitungan artikel ilmiah ini dalam menggunakan metode CPM menghasilkan jangka waktu 105 hari dan mengasilkan biaya setelah di crashing dalam penambahan tenaga kerja sebesar Rp. 5.568.464.052 dan penambahan jam kerja (lembur) Rp.5.603.725.490 Sedangkan menggunakan metode PERT menghasilkan jangka waktu 109 hari dan menghasilkan biaya setelah dicrashing  dalam penambahan tenaga  kerja  sebesar  Rp. 5.574.721.755  dan penambahan   jam kerja (lembur) Rp. 5.612.082.633. dengan probabilitas proyek  mencapai target 84%. Mempunyai perbandingan selisih biaya sebesar Rp. 6.257.703 dalam penambahan tenaga kerja dan Rp. 8.357.143 dalam penambahan jam kerja.
Studi Perencanaan Bangunan Atas Gedung Permata Indah di Desa Kedung Dowo Kabupaten Nganjuk Akbar Giynasiar Fatah; Ahmad Ridwan; Sigit Winarto
Jurnal Manajemen Teknologi & Teknik Sipil Vol 3, No 2 (2020): OCTOBER
Publisher : Faculty of Engineering, Kadiri University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (689.743 KB) | DOI: 10.30737/jurmateks.v3i2.1139

Abstract

Building construction is an object of a certain part of a building. Planning an earthquake-resistant building structure, one of the methods used is the Intermediate Moment Bearer Frame System (SRPMM). Based on SNI 03-1726-2012, SNI 03- 2847-2013, and SNI 1727-2013. In modeling made using SAP 2000 V20. The planning of the Permata Indah building, which is in Nganjuk Regency, is reviewed using static equivalent and response spectrum. The moment-bearing frame system is when the components and joints resist bending, shear, and axial forces. In this case, the moment-bearing frame system has a concept on the ductile portal structure system for joints or joints between columns and plastic beams. The calculated structural part is a floor plate that uses evenly distributed loads in trapezoidal loads and triangular loads; beam and column systems use concrete with analysis and calculation using the SAP 2000 V20 program. 9-D16 stirrup reinforcement Ø10-80, beam size 20cm x 25cm with main reinforcement 6-D16 stirrup Ø10-90, column size 30 cmx55 cm with main reinforcement 10- D16 stirrup 3 Ø10-110, practical column 15cm x 15cm 10 -D19 stirrup 3 Ø10-110, x and y-direction plate size Ø10-150 and Ø10-150. Konstruksi bangunan merupakan suatu obyek dari bagian tertentu dari suatu bangunan. Perencanaan struktur bangunan tahan gempa, salah satu metode yang digunakan adalah Sistem Rangka Pemikul Momen Menengah (SRPMM). Berdasarkan SNI 03-1726-2012, SNI 03-2847-2013, dan SNI 1727-2013. Dalam pemodelan dibuat dengan menggunakan SAP 2000 V20. Perencanaan gedung Permata Indah yang berada di Kabupaten Nganjuk ditinjau dengan menggunakan statik ekuivalen dan spektrum respon. Sistem rangka bantalan momen adalah ketika komponen dan sambungan menahan gaya lentur, geser, dan aksial. Dalam hal ini sistem rangka bantalan momen mempunyai konsep pada sistem struktur portal daktail untuk sambungan atau sambungan antar kolom dan balok plastik. Bagian struktural yang dihitung adalah pelat lantai yang menggunakan beban merata pada beban trapesium dan beban segitiga; Sistem balok dan kolom menggunakan beton dengan analisa dan perhitungan menggunakan program SAP 2000 V20. Tulangan sanggurdi 9-D16 Ø10-80, ukuran balok 20cm x 25cm dengan tulangan utama sanggurdi 6-D16 Ø10-90, ukuran kolom 30 cmx55 cm dengan tulangan utama sanggurdi 10-D16 3 Ø10- 110, kolom praktis 15cm x 15cm 10 -D19 sanggurdi 3 Ø10-110, pelat searah x dan y ukuran Ø10-150 dan Ø10-150.
Penerapan Metode CPM Dan PERT Pada Gedung Parkir 3 Lantai Grand Panglima Polim Kediri Tsalist Iluk; Ahmad Ridwan; Sigit Winarto
Jurnal Manajemen Teknologi & Teknik Sipil Vol. 3 No. 2 (2020): OCTOBER
Publisher : Kadiri University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30737/jurmateks.v3i2.1054

Abstract

The project is an activity carried out to products or services that have specific scheduling. Scheduling is determined by the relationship between activities made very detailed and accurate. Therefore, the purpose of the final task is to know how to implement the Critical Path Method (CPM) and Program Evaluation and Review Technique (PERT) in scheduling the project, which originally used the Bar Chart method with a duration of 140 days and resulted in a cost of Rp. 5.500.000.000. From the calculation result of this final task in using the CPM, the method generates a period of 105 days and provides cost after crashing in the labor increase of Rp. 5.568.464.052 and the increase in working hours (overtime) Rp. 5.603.725.490. While using the PERT method generates a period of 109 days and generates the cost after being crashing in the labor increase of Rp. 5.574.721.755 and the increase of working hours (overtime) of Rp.5.612.082.633 with a projected probability of reaching the target of 84 %. Has a comparison with the difference in cost of Rp. 6,257,703 in increased workforce and Rp. 8,357,143 other than working hours.Proyek merupakan suatu kegiatan yang dilakukan untuk menghasilkan produk / jasa yang mempunyai penjadwalan tertentu. Penjadwalan ditentukan oleh hubungan antar kegiatan yang dibuat sangat rinci dan akurat. Oleh karna itu tujuan dari artikel ilmiah ini adalah untuk mengetahui bagaimanakah penerapan metode Critical Path Method (CPM) dan Program Evaluation and Review Technique (PERT) pada penjadwalan proyek tersebut yang awalnya  menggunakan metode Bar Chart dengan durasi waktu 140 hari dan menghasilkan biaya sebesar Rp.5.500.000.000. Dari hasil perhitungan artikel ilmiah ini dalam menggunakan metode CPM menghasilkan jangka waktu 105 hari dan mengasilkan biaya setelah di crashing dalam penambahan tenaga kerja sebesar Rp. 5.568.464.052 dan penambahan jam kerja (lembur) Rp.5.603.725.490 Sedangkan menggunakan metode PERT menghasilkan jangka waktu 109 hari dan menghasilkan biaya setelah dicrashing  dalam penambahan tenaga  kerja  sebesar  Rp. 5.574.721.755  dan penambahan   jam kerja (lembur) Rp. 5.612.082.633. dengan probabilitas proyek  mencapai target 84%. Mempunyai perbandingan selisih biaya sebesar Rp. 6.257.703 dalam penambahan tenaga kerja dan Rp. 8.357.143 dalam penambahan jam kerja.
Modifikasi Beton Fc 9,8 Mpa Menggunakan Abu Ampas Kopi Shirfi Wimaya; Ahmad Ridwan; Sigit Winarto
Jurnal Manajemen Teknologi & Teknik Sipil Vol. 3 No. 2 (2020): OCTOBER
Publisher : Kadiri University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30737/jurmateks.v3i2.1096

Abstract

Concrete is a construction material that is widely used in building structures. Cement is the main constituent of concrete whose needs are increasing. The expansion of coffee shops in Kediri City resulted in an increase in the volume of coffee grounds waste, which can be used as an alternative to cement. The purpose of this study was to determine the value of the slump test, compressive strength test, and test the absorption capacity of the addition of coffee grounds ash to the concrete sample specimen using a cylinder is measuring 15cm x 30cm with 5 pieces of concrete quality K-125 or equivalent to fc '9.8 Mpa. Slump test results with a percentage of 4%, 8%, 12%, namely 2.5 cm, 0.5 cm and 2.5 cm. The results of the concrete compressive strength test with a percentage of 4% obtained the results of the compressive strength fc '10.51 Mpa or equivalent to K125, a percentage of 8% produces a compressive strength of fc' 8.39 and a percentage of 12% produces a compressive strength fc '7.56 Mpa equivalent to K100. The water absorption test results for 28 days resulted in an average value of 0.32 kg, 0.25 kg, 0.15 kg, and 33 kg.Beton merupakan salah satu bahan konstruksi yang banyak digunakan pada struktur bangunan. Semen merupakan penyusun utama beton yang kebutuhannya semakin meningkat. Perluasan kedai kopi di Kota Kediri mengakibatkan peningkatan volume limbah ampas kopi yang dapat digunakan sebagai alternatif pengganti semen. Tujuan penelitian ini adalah untuk mengetahui nilai uji slump, uji kuat tekan, dan uji daya serap penambahan abu ampas kopi pada benda uji beton dengan menggunakan silinder berukuran 15cm x 30cm dengan kualitas beton sebanyak 5 buah. K-125 atau setara dengan fc '9.8 Mpa. Hasil uji slump dengan persentase 4%, 8%, 12% yaitu 2.5 cm, 0.5 cm dan 2.5 cm. Hasil uji kuat tekan beton dengan persentase 4% didapatkan hasil kuat tekan fc '10 .51 Mpa atau setara dengan K125 persentase 8% menghasilkan kuat tekan fc '8,39 dan persentase 12% menghasilkan kekuatan tekan fc '7,56 Mpa setara dengan K100. Hasil pengujian daya serap air selama 28 hari menghasilkan nilai rata-rata 0,32 kg, 0,25 kg, 0,15 kg, dan 33 kg.
Beton Fc’ 21,7 Mpa Menggunakan Agregat Kasar Biji Genitri Muhammad Sulton Bahrudin; Agata Iwan Candra; Sigit Winarto
Jurnal Manajemen Teknologi & Teknik Sipil Vol. 3 No. 2 (2020): OCTOBER
Publisher : Kadiri University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30737/jurmateks.v3i2.1135

Abstract

Concrete in technological development has progressed very rapidly, so that it is able to open ideas in the use of organic materials as an alternative material for concrete. Genitri seeds are an organic material that can be used as an alternative to the building blocks of concrete. Genitri seeds have very good hardness and have a light volume weight so that they can reduce the large structure weight due to the weight of the concrete itself. The research method used in this study is an experimental method with genitri seeds as a mixture of coarse aggregate in concrete. This study aims to determine how much influence the compressive strength, slump value, volume weight, absorption, using a mixture of genitri seeds with a percentage of 5%, 10%, 15% of the weight of coarse aggregate. The results showed that the highest compressive strength was obtained by the addition of 5% genitri seeds, namely 20.75Mpa with an average slump value of 5.2. In the absorption test, the value of ¼ hour 0.040 1 hour 0.022 4 hours 0.006 24 hours 0.002 was obtained.Beton dalam perkembangan teknologi mengalami kemajuan yang sagat pesat, sehingga mampu membuka pemikiran dalam pemanfaatan material organik sebagai bahan alternatif penyusun beton. Biji genitri merupakan salah satu bahan organik yang dapat digunakan sebagai alternatif material penyusun beton. Biji genitri memiliki kekerasan yang sangat baik dan memiliki berat volume yang ringan sehingga dapat mengurangi berat struktur yang besar akibat beban dari berat beton itu sendiri. Metode penelitian yang digunakan pada penelitian ini adalah metode eksperimental dengan biji genitri sebagai bahan campuran agregat kasar pada beton. Penelitian ini bertujuan untuk mengetahui seberapa besar pengaruh terhadap kuat tekan, nilai slump, berat volume, absorpsi, dengan menggunakan bahan campuran biji genitri dengan persentase 5%,10%,15% dari berat agregat kasar. Dari hasil penelitian menunjukkan bahwa kuat tekan tertinggi diperoleh dengan penambahan biji genitri sebesar 5% yaitu 20,75Mpa  dengan nilai slump rata-rata 5,2. Pada pengujian absorpsi diperoleh nilai ¼ jam 0,040 1 jam 0,022 4 jam 0,006 24 jam 0,002.
Studi Perencanaan Bangunan Atas Gedung Permata Indah di Desa Kedung Dowo Kabupaten Nganjuk Akbar Giynasiar Fatah; Ahmad Ridwan; Sigit Winarto
Jurnal Manajemen Teknologi & Teknik Sipil Vol. 3 No. 2 (2020): OCTOBER
Publisher : Kadiri University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30737/jurmateks.v3i2.1139

Abstract

Building construction is an object of a certain part of a building. Planning an earthquake-resistant building structure, one of the methods used is the Intermediate Moment Bearer Frame System (SRPMM). Based on SNI 03-1726-2012, SNI 03- 2847-2013, and SNI 1727-2013. In modeling made using SAP 2000 V20. The planning of the Permata Indah building, which is in Nganjuk Regency, is reviewed using static equivalent and response spectrum. The moment-bearing frame system is when the components and joints resist bending, shear, and axial forces. In this case, the moment-bearing frame system has a concept on the ductile portal structure system for joints or joints between columns and plastic beams. The calculated structural part is a floor plate that uses evenly distributed loads in trapezoidal loads and triangular loads; beam and column systems use concrete with analysis and calculation using the SAP 2000 V20 program. 9-D16 stirrup reinforcement Ø10-80, beam size 20cm x 25cm with main reinforcement 6-D16 stirrup Ø10-90, column size 30 cmx55 cm with main reinforcement 10- D16 stirrup 3 Ø10-110, practical column 15cm x 15cm 10 -D19 stirrup 3 Ø10-110, x and y-direction plate size Ø10-150 and Ø10-150. Konstruksi bangunan merupakan suatu obyek dari bagian tertentu dari suatu bangunan. Perencanaan struktur bangunan tahan gempa, salah satu metode yang digunakan adalah Sistem Rangka Pemikul Momen Menengah (SRPMM). Berdasarkan SNI 03-1726-2012, SNI 03-2847-2013, dan SNI 1727-2013. Dalam pemodelan dibuat dengan menggunakan SAP 2000 V20. Perencanaan gedung Permata Indah yang berada di Kabupaten Nganjuk ditinjau dengan menggunakan statik ekuivalen dan spektrum respon. Sistem rangka bantalan momen adalah ketika komponen dan sambungan menahan gaya lentur, geser, dan aksial. Dalam hal ini sistem rangka bantalan momen mempunyai konsep pada sistem struktur portal daktail untuk sambungan atau sambungan antar kolom dan balok plastik. Bagian struktural yang dihitung adalah pelat lantai yang menggunakan beban merata pada beban trapesium dan beban segitiga; Sistem balok dan kolom menggunakan beton dengan analisa dan perhitungan menggunakan program SAP 2000 V20. Tulangan sanggurdi 9-D16 Ø10-80, ukuran balok 20cm x 25cm dengan tulangan utama sanggurdi 6-D16 Ø10-90, ukuran kolom 30 cmx55 cm dengan tulangan utama sanggurdi 10-D16 3 Ø10- 110, kolom praktis 15cm x 15cm 10 -D19 sanggurdi 3 Ø10-110, pelat searah x dan y ukuran Ø10-150 dan Ø10-150.
Pemanfaatan Limbah Galvalum Sebagai Substitusi Aggregat Kasar Pada Jobmix Beton Muhammad Bahrudin; Agata Iwan Candra; Sigit Winarto
Jurnal Manajemen Teknologi & Teknik Sipil Vol. 3 No. 2 (2020): OCTOBER
Publisher : Kadiri University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30737/jurmateks.v3i2.1152

Abstract

Concrete is one of the construction materials that is widely used. Currently, variations in concrete are being studied. Galvalum waste has high tensile properties but is mild. Its lightweight properties are expected to reduce the weight of the concrete itself. The purpose of this study is to find out the value of strong press, absorption, weight type (E), degree of saturation (Sr), moisture content (Wc), and porosity of the addition of galvalume waste. The method used is a experimental method. Variations in galvalum waste substitution used are 50% and 100% of the aggregate weight is roughT the sample used in the form of a cylinder size of 15cm x 30 cm with the initial quality of fc' 18.67 Mpa. The results of the strong press test showed that the galvalum waste subtitution has not been able to exceed the initial quality of the plan. The highest test result was obtained at a percentage of 50% with a strong press score of FC' 17.94 Mpa. In the percentage, absorption test results are 0.010%, the weight of the type is 2325 kg / m3, the pore number is 0.00232%, the water content is 0.108%, and porosity is 0.00108%.Beton merupakan salah satu bahan konstruksi yang banyak dipergunakan. Saat ini, pengguanaan variasi pada beton sedang banyak diteliti. Limbah galvalum memiliki sifat tarik yang tinggi namun ringan. Sifatnya yang ringan diharapkan mampu mengurangi berat beton itu sendiri. Tujuan dari penelitian ini adalah untuk mengetahui nilai kuat tekan, absorpsi, berat jenis (Æ”), angka pori (e),derajat kejenuhan (Sr), kadar air (Wc), dan porositas dari penambahan limbah galvalum. Metode yang digunakan merupakan metode eksperimen. Variasi pensubtitusi limbah galvalum yang digunakan yaitu 50% dan 100% dari berat agregat kasar. sampel yang digunakan berbentuk silinder ukuran 15cm x 30 cm dengan mutu awal fc’ 18.67 Mpa. Hasil uji kuat tekan menunjukkan bahwa subtitusi limbah galvalum belum mampu melebihi mutu awal rencana. Hasil uji tertinggi didapat pada prosentase 50% dengan nilai kuat tekan fc’ 17,94 Mpa. Pada prosentase tersebut, didapat hasil uji absropsi yaitu 0,010%,  berat jenis yaitu 2325 kg/m3, angka pori yaitu 0,00232%, kadar air yaitu 0,108% serta porositas yaitu 0,00108%.Â