Analysis of Transmitted and Received ECG Signal Based on Internet of Thing Using Web Browser and Server-Client HTML Protocol Dewi Rushalina; I Dewa Gede Hari Wisana; Priyambada Cahya Nugraha; Nazila Ragimova
Jurnal Teknokes Vol 15 No 4 (2022): December
Publisher : Jurusan Teknik Elektromedik, POLTEKKES KEMENKES Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/teknokes.v15i4.469

Abstract

Cardiovascular disease is one of the leading causes of death worldwide. One of the reasons for the large number of deaths from heart disease is the lack of regular cardiac monitoring. Electrocardiograph (ECG) is a method of monitoring heart conditions. There are still many ECG examinations in hospitals that are carried out directly in certain places and the results can only be seen at that time. Meanwhile, when negligence or carelessness occurs, it can endanger the patient due to delays in handling. One of the efforts that can be made to improve service to heart patients is by having ECG monitoring based on IoT (Internet of things). The purpose of this study is to analyze the ECG signals sent and received by IoT media so that they are useful for the diagnostic process. The contribution of this research is to know the shape of the ECG signal that is sent and received through IoT media. The procedure to achieve this goal is with the AD8232 sensor whose output will be processed through the microcontroller and displayed on computer and smartphones via IoT. From this research, the results obtained that the average value of lost data at BPM 60 and BPM 120 is quite good, namely 21.26% and 24.44%.hile the average time delay value at BPM 60 and BPM 120 is also quite good, namely 0.023 s and 0.03 s. So, it can be concluded that the sending of IoT-based ECG signals affects the form of signals sent and received. The results of this study are expected to be developed in further research with development in the form of adding leads or adding BPM parameters.
Electronic Stethoscope Design with IoT (Internet of Things)-based Disease Symptom Detection Torib Hamzah; Endang Dian Setioningsih; Sumber Sumber; Nazila Ragimova
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 4 (2022): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i4.247

Abstract

Auscultation is a technique or method most often used by medical personnel in the initial examination of patients. One way is to use a stethoscope. However, this method has its drawbacks because the diagnosis is carried out subjectively and cannot be relied on with the accuracy to diagnose the symptoms of heart defects. Thus, the purpose of this study is to create an IoT system for electronic stethoscopes with BPM value output and make analog filters to eliminate noise interference which was a major obstacle in previous studies. The contribution to this study is to make it easier for medical users to monitor vital conditions, namely BPM remotely and produce BPM values in real-time. The method used in this study was to use a mic condensor placed on the patient's chest to detect pressure changes that occurred. This change in pressure causes a change in the voltage output value on the condensor mic. Output dari mic condenser masuk dan diproses di rangkaian PSA. Output sinyal dari PSA masuk ke mikrokontroler yang telah diprogram. Hasil yang dipeoleh dari pengukuran mengasilkan nilai error pengukuran nilai BPM dari 5 responden dan diperoleh nilai error yang dihasilkan dari responden 1 diperoleh error sebesar 0.33 BPM, responden 2 diperoleh nilai error sebesar 0,67 BPM, responden 3 memiliki nilai error sebesar 0,5 BPM, responden 4 nilai error sebesar 0,67 dan responden 5 mempunyai nilai error sebesar 0,67 BPM. The results of the statistical test were also obtained P-Value>0.05 which explained that the resulting value did not have a significant difference and could be used for medical purposes. This research can help make it easier for doctors to analyze and diagnose symptoms of heart defects because this system is equipped with the detection of disease symptoms.