Claim Missing Document
Check
Articles

Found 2 Documents
Search

Analisa Laju Permukaan Keausan Pada Model Uji Mekanis Bushing Kuningan Sutarno; Nugrah Rekto Prabowo; Mastur
Accurate: Journal of Mechanical Engineering and Science Vol. 2 No. 1 (2021): April 2021
Publisher : Politeknik Negeri Cilacap

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35970/accurate.v2i1.584

Abstract

Bushing is a bearing between movable and immovable components. These spare parts function are to hold the rotating shaft and through the gear box into the shaft which is held by the brass material bushing, where those processes are able to reduce the vibrations and the shock of shock loads. The purpose of this research is to know the level of roughness and wear rate of brass bushing, this research is conducted to find out how efficient it is, the use of a bushing with a field that is very likely to have a large shock load and to know the wear test data, and roughness of the brass bushing. The type of this research used an experimental method. From the results of the study it was concluded that to get the roughness and wear value using a conventional lathe, the spindle rotation was 970 rpm. Based on the experiments with predetermined parameters, the lowest roughness value was Ra 1.13 and the highest roughness was Ra 2.41. In the experiments for the wear test of each specimen, the wear rate obtained after the initial weight was subtracted from the third one hour weight, from the lightest of 0.07 grams and the heviest of 1.62 grams.
Analisis Perbandingan Kinerja Refrigeran R134a dan MC-22 pada AC Split Mastur; Nana Supriyana; Warso; Sutarno
Accurate: Journal of Mechanical Engineering and Science Vol. 3 No. 2 (2022): October 2022
Publisher : Politeknik Negeri Cilacap

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35970/accurate.v3i2.1754

Abstract

AC (Air Conditioner) is one of the cooling machines, whose use is currently increasing. One important component that helps cooling the AC (Air Conditioner) is the refrigerant. Refrigerant is a kind of material or substance in the form of liquid and gas which is usually flowed in the refrigeration machine installation. The purpose of this study was to determine the performance (COP), electrical energy consumption, and cooling rate from the use of refrigerants R134a and MC-22. The independent variables in this research are refrigerant R134a and refrigerant MC-22. The dependent variable in this study is COP (Coefficient of Performance), electrical energy consumption, and cooling rate. The control variable in this study was using time variations. The research material is refrigerant R134a and MC-22 The results of this study showed that R134a refrigerant has a better COP value than MC-22 refrigerant, where the COP value at 60 minutes for R134a refrigerant is 8.6 while for MC-22 refrigerant is 8.0. At 60 minutes the use of refrigerant R134a, the electrical energy used is 385.00 W.h. Meanwhile, 60 minutes of the use of refrigerant MC-22, the electrical energy used is 455.40 W.h.