Robust Canonical Correlation Analysis on Leakage Current Behaviors of Geothermal Polluted Porcelain Insulators Waluyo, Waluyo; Sinisuka, Ngapuli Irmea; Suwarno, Suwarno
Jurnal Semesta Teknika Vol 12, No 2 (2009): NOVEMBER 2009
Publisher : Jurnal Semesta Teknika

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This study presents the leakage current measurements results of three natural geothermal polluted porcelain insulators. The insulators consisted of one new-clean insulator, as reference, and three polluted insulators. The carried out measurements were leakage current and applied high voltage waveforms, used a two-channel storage digital oscilloscope, in a hermetically sealed chamber, where temperature, humidity, pressure and applied voltage amplitude could be adjusted and measured simultaneously. The leakage current waveforms were analyzed using the FFT and the statistical concerns were analyzed by the Fast-Minimum Covariance Determinant (FMCD) of robust multivariate statistical tools, and canonical correlation analysis (CCA). The result indicated that after the fundament, the second highest of harmonics leakage current were fifth harmonics. The leakage current waveforms were significantly influenced by humidity, besides pollution. The dependent or output variables are linear functions of independent or input variables. Based on CCA, the dependent parameters depended on input parameters tightly, with the canonical correlations were more than 0.99. The leakage current  amplitudes were still predominantly influenced by applied voltage amplitudes, where the phase angles and THD were slightly influenced by relative humidity. On these experimental measurements, the insulators were still in normal operation. 
COMPARATIVE STUDY OF LEAKAGE CURRENT PROPERTIES ON THE NEW-CLEAN PORCELAIN AND EPOXY RESIN OUTDOOR INSULATORS DUE TO VARIOUS PARAMETERS -, Waluyo; Sinisuka, Ngapuli Irmea; -, Suwarno; Djauhari, Maman Abadurachman
JURNAL TEKNOLOGI TECHNOSCIENTIA Technoscientia Vol 2 No 2 Februari 2010
Publisher : Lembaga Penelitian & Pengabdian Kepada Masyarakat (LPPM), IST AKPRIND Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (906.857 KB) | DOI: 10.34151/technoscientia.v2i2.460

Abstract

This manuscript presents the experimental results of leakage current waveform properties which produced on the new-clean porcelain and epoxy resin insulators due to various voltage, temperature, humidity and pressure parameters. The measurements have been done in the hermetically sealed chamber where the parameters could be regulated and monitored or recorded simultaneously. The examined leakage current parameters were wave amplitude, phase angle or power factor, first to thirteenth odd harmonics and THD. The analysis was done with some multivariate statistical tools, such as correlation matrix, pca and scree plot. The results indicated that leakage current amplitude and phase angle were influenced by humidity, indicated by correlation coefficients as 0.56 and -0.88 respectively on new-clean porcelain insulator. Otherwise, on the new-clean epoxy resin insulator, leakage current magnitude influenced to the phase angle as -0.75. These were supported by principal component analysis. Based on the scree plots, the extracted of information quality were higher than 80%.
COMPARATIVE STUDY OF LEAKAGE CURRENT PROPERTIES ON THE NEW-CLEAN PORCELAIN AND EPOXY RESIN OUTDOOR INSULATORS DUE TO VARIOUS PARAMETERS -, Waluyo; Sinisuka, Ngapuli Irmea; -, Suwarno; Djauhari, Maman Abadurachman
JURNAL TEKNOLOGI TECHNOSCIENTIA Technoscientia Vol 2 No 2 Februari 2010
Publisher : Lembaga Penelitian & Pengabdian Kepada Masyarakat (LPPM), IST AKPRIND Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.34151/technoscientia.v2i2.460

Abstract

This manuscript presents the experimental results of leakage current waveform properties which produced on the new-clean porcelain and epoxy resin insulators due to various voltage, temperature, humidity and pressure parameters. The measurements have been done in the hermetically sealed chamber where the parameters could be regulated and monitored or recorded simultaneously. The examined leakage current parameters were wave amplitude, phase angle or power factor, first to thirteenth odd harmonics and THD. The analysis was done with some multivariate statistical tools, such as correlation matrix, pca and scree plot. The results indicated that leakage current amplitude and phase angle were influenced by humidity, indicated by correlation coefficients as 0.56 and -0.88 respectively on new-clean porcelain insulator. Otherwise, on the new-clean epoxy resin insulator, leakage current magnitude influenced to the phase angle as -0.75. These were supported by principal component analysis. Based on the scree plots, the extracted of information quality were higher than 80%.
Robust Canonical Correlation Analysis on Leakage Current Behaviors of Geothermal Polluted Porcelain Insulators Waluyo, Waluyo; Sinisuka, Ngapuli Irmea; Suwarno, Suwarno
Semesta Teknika Vol 12, No 2 (2009): NOVEMBER 2009
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/st.v12i2.732

Abstract

This study presents the leakage current measurements results of three natural geothermal polluted porcelain insulators. The insulators consisted of one new-clean insulator, as reference, and three polluted insulators. The carried out measurements were leakage current and applied high voltage waveforms, used a two-channel storage digital oscilloscope, in a hermetically sealed chamber, where temperature, humidity, pressure and applied voltage amplitude could be adjusted and measured simultaneously. The leakage current waveforms were analyzed using the FFT and the statistical concerns were analyzed by the Fast-Minimum Covariance Determinant (FMCD) of robust multivariate statistical tools, and canonical correlation analysis (CCA). The result indicated that after the fundament, the second highest of harmonics leakage current were fifth harmonics. The leakage current waveforms were significantly influenced by humidity, besides pollution. The dependent or output variables are linear functions of independent or input variables. Based on CCA, the dependent parameters depended on input parameters tightly, with the canonical correlations were more than 0.99. The leakage current  amplitudes were still predominantly influenced by applied voltage amplitudes, where the phase angles and THD were slightly influenced by relative humidity. On these experimental measurements, the insulators were still in normal operation.Â