Analisis Implementasi Komunikasi Modbus TCP/IP dalam Penerapan Visualisasi Data Hasil Produksi pada Sistem Andon Line Production Bonanza Yoma Pratama; Efi Anisa
Jurnal Asiimetrik: Jurnal Ilmiah Rekayasa dan Inovasi Volume 5 Nomor 1 Tahun 2023
Publisher : Fakultas Teknik Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/asiimetrik.v5i1.3791

Abstract

Andon refers to an information system aimed at management, maintenance, planners, or other workers regarding quality, process, or quantity issues. To support accurate data communication, a reliable protocol and high precision are required. The Modbus TCP/IP protocol is compatible with Andon systems. This study aims to analyze the implementation of Modbus TCP/IP communication in the application of production data visualization in online production systems. At a certain distance, the antenna's data must display the data's precision in real time. The average data transfer time at the farthest distance tested, 50 meters, was 0.0043 seconds, indicating that the longer the distance between the client and server, the longer the waiting time tends to be, but does not exceed 0.01 seconds if it does not affect production activities. These results are still pertinent to the information required by the organization.