Nagam Shakir Turkie Al-Awadi
Unknown Affiliation

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

A Nobel Chemiluminescence and Fluorescence Energy Transfer Three Inlets Cell for the Determination of Hydrogen Peroxide via Continuous Flow Injection Analysis Nagam Shakir Turkie Al-Awadi
Journal of Global Pharma Technology Volume 11 Issue 05.
Publisher : Journal of Global Pharma Technology

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The study presents a sensitive, fast and easy assay method that was developed for determination of hydrogen peroxide  via continuous mode of FIA i.e. new noble chemiluminescence and fluorescence cell with specially designed unit cell of three inlets and  one outlet  to measure a total luminescence which include the chemiluminescence generated and the fluorescence that was created by the in situ radiation of the released chemiluminescence light using fluorescence molecule which gives an emission spectrum at 530 nm The method is based on the use of fluorescent molecule as an acceptor fluorophore where by it is irradiated internally and instantly when the generation of luminol chemiluminescence light is used as internal source for irradiation of fluorescein molecule to give fluorescence light , this reaction and analysis occur in a specially homemade  designed cell. Experimental parameters that lead to optimum concentrations of all chemicals and physicals variables .A sample volume of 75 μL was used throughout the whole work. It was found that the linear working range was between 20-500 μmol. L-1, with correlation coefficient of 0.9969 and limit of detection L.O.D. (S/N =3) 1.275ng/sample by using step wise dilution of the minimum concentration that was achieved by the calibration graph. Repeatability of less than 0.25% for ten successive injections of 250 μmol.L-1 & 400μmol .L-1 of hydrogen peroxide .The method was applied successively in determination of hydrogen peroxide in some pharmaceutical disinfectants.Keywords: Chemiluminescence, Flow injection analysis, Hydrogen peroxide, In situ fluorescence.
A Novel Instrumental Method for the Determination of Cobalt (II) ion using NAG-ADF-300-2 Analyser, via the Formation of a Precipitating Reaction Product Through On-Line Long Distance (300 mm) and Short Path Length (2 mm) Chasing of Sample Segment Nagam Shakir Turkie Al-Awadi
Journal of Global Pharma Technology Volume 11 Issue 05.
Publisher : Journal of Global Pharma Technology

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

A new instrument is presented for determination of Co (II) ion using precipitation reaction NAG-ADF-300 – 2 analyser is used for attenuation of incident light (white snow light emitting diode) at two stages, first one is 110 mm while the second one is 60 mm with a separation distance of 100 mm reaction of Co (II) ion with rubeanic acid in alkaline medium forms a black precipitate. The attenuation of this precipitate to the incident light is measured in a very repeatable, reproducible manner of RSD% less than 1% at variable concentrations. Line or calibration graph extend from 0.02 – 0.1 mmol / L Cobalt (II) ion. 30 sample / hr. can be handled. This instrument is easy to use and have extended ranged of working parameters. 50-500 µL samples can be manipulated using 2- line system. Limit of detection (L.O.D) is 0.5µmol L-1 at 50 µL for cell A and 7 µmol L-1 at 200 µL sample volume for cell B. The method was applied successfully for the determination of Co (II) ion in two different alloys.Key word: Turbidometry, Flow injection analysis, Cobalt (ll) Ion. and snow white light emitting diode.