Claim Missing Document
Check
Articles

Found 5 Documents
Search
Journal : Moluccas Health Journal

Uji Fisikokimia dan Mikrobiologi Air Minum Isi Ulang pada Depo Air Minum Di Kecamatan Sirimau Kota Ambon M Pentury; Adrianan Ritje Nendissa
MOLUCCAS HEALTH JOURNAL Vol 2, No 1 (2020): Moluccas Health Journal Edisi April 2020
Publisher : Lembaga Penerbitan Fakultas Kesehatan Universitas Kristen Indonesia Maluku

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (472.916 KB) | DOI: 10.54639/mhj.v2i1.437

Abstract

Kebutuhan air minum di Indonesia semakin meningkat, seiring pertambahan jumlah penduduk dan semakin berkurangnya daerah tangkap air akibat berbagai aktivitas masyarakat. Berbagai upaya dilakukan untuk memenuhi kebutuhan akan air minum dengan cara membuka depot-depot air minum isi ulang. Di Kota Ambon tercatat 65 depot air minum isi ulang yang telah memiliki ijin diantaranya 31 depot berlokasi di Kecamatan Sirimau. Produksi air minum oleh industri maupun oleh depot-depot air minum isi ulang (AMIU) harus memenuhi persyaratan air minum yang diatur dalam Peraturan Menteri Kesehatan Republik Indonesia tentang persyaratan kualitas air minum, yang meliputi persyaratan bakteriologis, kimiawi, fisik, dan radioaktif. Beberapa parameter fisik, kimia dan mikrobiologi yang wajib diantaranya Total Dissolve Solid (TDS), kesadahan (CaCO3) dan Total Coliform. Kadar maksimum TDS yang diperbolehkan untuk dikonsumsi adalah 500 mg/L, untuk kesadahan (CaCO3) adalah 500 mg/L dan Total Coliform adalah 0 per 100 ml sampel.  Penelitian ini bertujuan untuk  mengetahui kandungan Total Dissolve Solid, Kesadahan (CaCO3) dan Total Coliform dalam air minum pada depot air minum isi ulang di Kecamatan Sirimau. Metode yang digunakan adalah observasional dengan pendekatan deskriptif dan analisa laboratorium dengan maksud melakukan pengamatan laboratorium untuk mendapatkan informasi tentang kandungan Total Dissolve Solid (TDS), kesadahan (CaCO3) dan Total Coliform dalam air minum pada depot air minum isi ulang yang dilakukan di Balai Laboratorium Kesehatan Provinsi Maluku. Berdasarkan hasil pengujian parameter TDS, kesadahan (CaCO3) dan Total Coliform, terdapat 1 depot yang belum memenuhi baku mutu dengan kandungan Total Dissolve Solid (TDS), 510/100 ml. Pada pengujian terhadap kesadahan (CaCO3) seluruh depot masih dibawah standar baku mutu atau layak dikonsumsi, hal yang sama juga terjadi dengan pengujian Total Colifor, dimana semua depot air minum isi ulang memenuhi baku mutu total coliform. Semua depot memenuhi baku mutu kadar nilai total coliform yang terkandung adalah 0/100 ml sampel.Kata Kunci: Air minum isi ulang, analisa fisik, analisa kimia, analisa Mikrobiologi
Gambaran Kondisi Lingkungan Fisik Ruang Rawat Inap di RS SUMBER HIDUP – GPM Kota Ambon Andriana Ritje Nendissa; Donny J Pugesehan; Anastasia Arista Ohman
MOLUCCAS HEALTH JOURNAL Vol 4, No 1 (2022)
Publisher : Lembaga Penerbitan Fakultas Kesehatan Universitas Kristen Indonesia Maluku

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54639/mhj.v1i1.699

Abstract

The condition of the physical environment of the inpatient room can affect the psychological nature of the patient. The physical environment can be in the form of lighting, noise and temperature. The purpose of this study was to determine the conditions of noise, lighting and temperature in the inpatient room. The location of this research is in the inpatient room of Sumber Hidup Hospital – GPM Ambon City, in June 2021. This research is a descriptive study with quantitative methods. The sample used in this study is total sampling, which means that all members of the population are sampled, namely 31 rooms. Based on the Decree of the Minister of Health of the Republic of Indonesia No. 7 of 2019 concerning the environmental health of hospitals, it was found that the inpatient room at Sumber Hidup Hospital - GPM in Ambon City from the research results for Noise did not meet the 100% requirements with an average value of 60.9 dBA, meaning that the noise was more than the Standard Standard. Quality is 45 dBA. The lighting also does not meet the 100% requirements with an average value of 165.32 Lux, meaning that the lighting is less than the Quality Standard, which is 250 Lux. and the temperature does not meet the 100% requirements with an average value of 27.1 °C, meaning that the temperature is more than the Quality Standard, which is 22-23 °C. Conclusion: The location of the hospital close to the highway can affect noise. The lighting for the location of the room is blocked by natural light. The temperature of the ventilation system is inadequate and the air conditioner must be regularly maintained by IPSRS officers.Keywords: Hospitalization, Lighting, Noise, and Temperature
Studi Tingkat Kepadatan Lalat di Pasar Mardika Kota Ambon Andriana Ritje Nendissa
MOLUCCAS HEALTH JOURNAL Vol 4, No 2 (2022)
Publisher : Lembaga Penerbitan Fakultas Kesehatan Universitas Kristen Indonesia Maluku

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54639/mhj.v4i2.983

Abstract

Flies are insects that are vectors of disease in humans. Based on an initial survey at the Mardika Market, Ambon City, there were many piles of garbage and many flies were seen in the piles of garbage. Garbage in the Mardika Market in Ambon City is not transported every day so that it can become a breeding ground for flies, because there are many piles of rotting garbage which are the most potential places to find food and breed. In Mardika Market, there are many flies, especially in vegetable shops, chicken shops, fruit shops and chicken shops. The existence of these flies is due to factors that support life for flies. The presence of flies can be used as an indicator of poor sanitation in a place. The purpose of this study was to determine the level of fly density in the Mardika Market, Ambon City. This research is descriptive in nature by describing the research location in the market to attach the design at the Mardika Market, Ambon City. The results showed that the rate of density at each point of sale had exceeded the standard of 7-22 so it could be said to be dense. The factors that can affect the breeding of flies are; Distance, Temperature and Light. Suggestion ; for the Government and the City Sanitation Service as well as sellers in the market so that they can pay attention to environmental sanitation in the market and the factors that affect the speed of flies.Keywords: Flies Density Level, Distance, Temperature and Light
Gambaran Kondisi Lingkungan Fisik Ruang Rawat Inap di RS SUMBER HIDUP – GPM Kota Ambon Andriana Ritje Nendissa; Donny J Pugesehan; Anastasia Arista Ohman
MOLUCCAS HEALTH JOURNAL Vol 4, No 1 (2022): April
Publisher : Lembaga Penerbitan Fakultas Kesehatan Universitas Kristen Indonesia Maluku

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54639/mhj.v1i1.699

Abstract

The condition of the physical environment of the inpatient room can affect the psychological nature of the patient. The physical environment can be in the form of lighting, noise and temperature. The purpose of this study was to determine the conditions of noise, lighting and temperature in the inpatient room. The location of this research is in the inpatient room of Sumber Hidup Hospital – GPM Ambon City, in June 2021. This research is a descriptive study with quantitative methods. The sample used in this study is total sampling, which means that all members of the population are sampled, namely 31 rooms. Based on the Decree of the Minister of Health of the Republic of Indonesia No. 7 of 2019 concerning the environmental health of hospitals, it was found that the inpatient room at Sumber Hidup Hospital - GPM in Ambon City from the research results for Noise did not meet the 100% requirements with an average value of 60.9 dBA, meaning that the noise was more than the Standard Standard. Quality is 45 dBA. The lighting also does not meet the 100% requirements with an average value of 165.32 Lux, meaning that the lighting is less than the Quality Standard, which is 250 Lux. and the temperature does not meet the 100% requirements with an average value of 27.1 °C, meaning that the temperature is more than the Quality Standard, which is 22-23 °C. Conclusion: The location of the hospital close to the highway can affect noise. The lighting for the location of the room is blocked by natural light. The temperature of the ventilation system is inadequate and the air conditioner must be regularly maintained by IPSRS officers.Keywords: Hospitalization, Lighting, Noise, and Temperature
Uji Fisikokimia dan Mikrobiologi Air Minum Isi Ulang pada Depo Air Minum Di Kecamatan Sirimau Kota Ambon M Pentury; Adrianan Ritje Nendissa
MOLUCCAS HEALTH JOURNAL Vol 2, No 1 (2020): April
Publisher : Lembaga Penerbitan Fakultas Kesehatan Universitas Kristen Indonesia Maluku

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54639/mhj.v2i1.437

Abstract

Kebutuhan air minum di Indonesia semakin meningkat, seiring pertambahan jumlah penduduk dan semakin berkurangnya daerah tangkap air akibat berbagai aktivitas masyarakat. Berbagai upaya dilakukan untuk memenuhi kebutuhan akan air minum dengan cara membuka depot-depot air minum isi ulang. Di Kota Ambon tercatat 65 depot air minum isi ulang yang telah memiliki ijin diantaranya 31 depot berlokasi di Kecamatan Sirimau. Produksi air minum oleh industri maupun oleh depot-depot air minum isi ulang (AMIU) harus memenuhi persyaratan air minum yang diatur dalam Peraturan Menteri Kesehatan Republik Indonesia tentang persyaratan kualitas air minum, yang meliputi persyaratan bakteriologis, kimiawi, fisik, dan radioaktif. Beberapa parameter fisik, kimia dan mikrobiologi yang wajib diantaranya Total Dissolve Solid (TDS), kesadahan (CaCO3) dan Total Coliform. Kadar maksimum TDS yang diperbolehkan untuk dikonsumsi adalah 500 mg/L, untuk kesadahan (CaCO3) adalah 500 mg/L dan Total Coliform adalah 0 per 100 ml sampel.  Penelitian ini bertujuan untuk  mengetahui kandungan Total Dissolve Solid, Kesadahan (CaCO3) dan Total Coliform dalam air minum pada depot air minum isi ulang di Kecamatan Sirimau. Metode yang digunakan adalah observasional dengan pendekatan deskriptif dan analisa laboratorium dengan maksud melakukan pengamatan laboratorium untuk mendapatkan informasi tentang kandungan Total Dissolve Solid (TDS), kesadahan (CaCO3) dan Total Coliform dalam air minum pada depot air minum isi ulang yang dilakukan di Balai Laboratorium Kesehatan Provinsi Maluku. Berdasarkan hasil pengujian parameter TDS, kesadahan (CaCO3) dan Total Coliform, terdapat 1 depot yang belum memenuhi baku mutu dengan kandungan Total Dissolve Solid (TDS), 510/100 ml. Pada pengujian terhadap kesadahan (CaCO3) seluruh depot masih dibawah standar baku mutu atau layak dikonsumsi, hal yang sama juga terjadi dengan pengujian Total Colifor, dimana semua depot air minum isi ulang memenuhi baku mutu total coliform. Semua depot memenuhi baku mutu kadar nilai total coliform yang terkandung adalah 0/100 ml sampel.Kata Kunci: Air minum isi ulang, analisa fisik, analisa kimia, analisa Mikrobiologi