p-Index From 2020 - 2025
0.817
P-Index
This Author published in this journals
All Journal Jurnal Teknik Mesin
Claim Missing Document
Check
Articles

Found 4 Documents
Search

Analisis Pengaruh Perubahan Beban Boiler Terhadap Konservasi Energi di PLTU SU5 Permana, Dadang Suhendra
Jurnal Teknik Mesin (Journal Of Mechanical Engineering) Vol 10, No 3 (2021)
Publisher : Universitas Mercu Buana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22441/jtm.v10i3.11892

Abstract

               Kinerja PLTU yang memadai saat ini sangat diperlukan, mengingat konsumsi energinya yang sangat besar, terlebih lagi rantai konversi energinya sangat panjang, sehingga sangat tepat untuk dikonservasi.               Untuk mendapatkan nilai konservasi terbaik, dibutuhkan kehandalan yang terkendali, baik secara operasional maupun perawatan. Oleh karenanya, pemantauan nilai efisiensi memegang peranan penting dalam penilaian Performance Base Regulatory suatu PLTU, untuk dijadikan sebagai acuan dasar pengendalian kerja.               Perhitungan meliputi; keseimbangan energi boiler, keseimbangan energi siklus uap, efisiensi sistem pembangkit dan nilai NPHR PLTU SU5. Dari hasil analisis perhitungan terpantau sebesar 38,10 % dan 2260 kcal/kWh. Performa PLTU SU5 dapat mencapai 64,5 % berdasarkan nilai NPHR dari target kinerja yang telah ditetapkan pada kontrak management yaitu sebesar 2561,81 kcal/kWh.
Analisis Kinerja Sistim Kompresor Udara di Jalur Produksi PT.X Melalui Audit Energi Permana, Dadang Suhendra
Jurnal Teknik Mesin (Journal Of Mechanical Engineering) Vol 10, No 2 (2021)
Publisher : Universitas Mercu Buana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22441/jtm.v10i2.11893

Abstract

Analisis akan dilakukan untuk mengetahui kodisi kinerja kompresor, penurunan tekanan pada sistim pemipaan, kerugian akibat pressure band, serta estimasi kerugian financial akibat permasalahan tersebut. Diperlukan data premier, data sekunder dan data penunjang lainnya untuk menganalisisnya. Data-data diperoleh dari hasil pengukuran antara lain flow rate, tekanan, daya temperature dan dimensi pipa. Adapun data lainnya diperoleh dari kondisi aktual dilapangan dan informasi dari pengguna.            Hasil analisis memperlihatkan penurunan kinerja kompresor rata-rata antara 13% - 52%. Kompresor No. 4 paling rendah kinerjanya, karena perawatan general overhaul belum dilaksanakan. Kompresor ini direkomendasikan untuk berhenti beroperasian, karena menyebabkan kerugian biaya listrik sebesar Rp192.714.120/tahun. Ditemukan perbedaan tekanan antara supply dan demand yang sangat besar pada kompresor no. 5, yakni 2,5 bar dengan estimasi kerugian financial sebesar Rp 226.720.000/tahun. Melengkapi pengendalian kerja kompresor dengan inverter dan sistem pengontrol terpusat (central controller) akan dapat mengurangi kerugian biaya listrik sebesar Rp 94.640.000/tahun.
EFFECT OF LOADING FLUCTUATION ON EFFICIENCY BOILER PLTU UNIT I SOUTH MINAHASA Permana, Dadang Suhendra
Jurnal Teknik Mesin (Journal Of Mechanical Engineering) Vol 9, No 1 (2020)
Publisher : Universitas Mercu Buana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22441/jtm.v9i1.7044

Abstract

Many aspects affect the performance of a power plant . One of her in the form of fluctuations in load of Control Center Interkoneksi expenses electricity network , as that occurred at the power plant Unit 1 South Minahasa. It is the possibility of big will air an influence on the efficiency of boiler power plant , which is now a reference in the assessment Performance Regulatory Base a steam power plant. Through the analysis of the effect of fluctuations in the workload of the Efficiency Boiler power plant Amurang Unit 1 Unit 1, the expected performance of the existing power plant can be in the know , s ehingga Performance Regulatory Base him untracked . Thus the energy saving effort will be achieved and at the same time encourage environmental preservation efforts. Because the Amurang PLTU Unit 1 uses medium rank coal / LRC which is environmentally friendly (low sulfur and ash content).
Analisis Kinerja Turbin Uap Sebelum Dan Sesudah Overhaul PLTU X Fadila, Anis; Permana, Dadang Suhendra
Jurnal Teknik Mesin (Journal Of Mechanical Engineering) Vol 13, No 1 (2024)
Publisher : Universitas Mercu Buana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22441/jtm.v13i1.18908

Abstract

Ketersediaan energi listrik dituntut untuk selalu ada dan kontiyu, sehingga diperlukan pembangkit listrik yang handal dan efisien. Turbin uap bekerja dalam temperatur yang tinggi dan jangka waktu yang lama, sehingga turbin uap dituntut harus mampu beroperasi dengan tingkat stabilitas yang tinggi dari keadaan tanpa beban hingga ke beban penuh. Seiring berjalannya waktu, dengan kondisi tersebut diperkirakan turbin uap mengalami penurunan kinerja. Untuk mengatasinya, maka turbin uap perlu dioverhaul. Penelitian ini bertujuan untuk mengetahui dampak overhaul terhadap kinerja turbin uap PLTU X. Pengambilan data dilakukan dengan metode analisis kuantitatif data sekunder. Untuk menganalisanya digunakan metode perhitungan berdasarkan kesetimbangan masa uap dan energi dalam entalpi yang masuk dan keluar turbin dengan daya keluaran generator (output generator). Dari hasil analisis termodinamika didapatkan adanya peningkatan kinerja turbin uap setelah dilakukan overhaul yaitu daya turbin mengalami pengingkatan sebesar 29,413 MW, efisiensi isentropik turbin uap meningkat sebesar 0,234%, THR mengalami penurunan sebesar 278,08 kcal/kWh dan efisiensi turbin uap mengalami peningkatan sebesar 2,78%.