Pengaruh Slice Thickness terhadap Signal to Noise Ratio (SNR) dari Hasil Penyinaran CT Scan di RSUP Prof. Dr. I.G.N.G Ngoerah Lusi Putu Russita Kusumaningsih; I Bagus Made Suryatika; Ni Luh Putu Trisnawati; Rozi Irhas
Kappa Journal Vol 7 No 2 (2023): Agustus
Publisher : Universitas Hamzanwadi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29408/kpj.v7i2.7675

Abstract

A research has been carried out on the effect of slice thickness on SNR values from the results of CT Scan irradiation at Prof. Dr. I.G.N.G Ngoerah Hospital.  Variations in the thickness of the slices used are 1 mm, 3 mm, 5 mm, and 7 mm.  The tube voltage, tube current, and FOV used are constant, namely 120 kV, 200 mA, and 380 mm.  SNR value analysis was calculated using the average object value and SD background for each material.  Based on the results of a simple linear regression test, the thickness of the slices obtained has an effect of 99.9% on the SNR value.  These results indicate that the greater the thickness of the slice used, so the SNR value will increasesas the SNR value increases, it will improve image quality.
Perancangan Alat Ukur Intensitas Cahaya menggunakan Sensor BH1750 Berbasis Mikrokontroler ATMega328P Tominikus Benyamin Bano; I Gusti Agung Widagda; Ni Luh Putu Trisnawati; I Made Satriya Wibawa; I Ketut Putra; I Nengah Sandi
Kappa Journal Vol 8 No 1 (2024): April
Publisher : Universitas Hamzanwadi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29408/kpj.v8i1.24917

Abstract

The design of a light intensity measuring instrument using the BH1750 sensor based on the ATMega328P microcontroller has been successfully created. The results of light intensity data are measured by using the BH1750 sensor which receives a data signal in the form of light intensity. In order to get results that are in accordance with the reference tool, the design of a light intensity measuring instrument by using the BH1750 sensor based on the ATmega328P microcontroller is carried out in the Electronics and Instrumentation Laboratory and Computing Laboratory, Physics Study Program, FMIPA, Udayana University, Jimbaran, Bali. Then the results of the design of tool and reference tool processed into graphical form and proven by employing a linear regression equation. The measurement results of light intensity are displayed on a 16x2 LCD. The test results of the design tool against the reference tool shown that the level of accuracy of the design tool is relatively high.