p-Index From 2020 - 2025
0.408
P-Index
This Author published in this journals
All Journal Jurnal Edunitro
Jocke Rapar
Pendidikan Teknik Elektro, Fakultas Teknik, Universitas Negeri Manado

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Analisis dan Perancangan Instalasi Penerangan Gedung Perpustakaan Universitas Negeri Manado Kluivert Abast; Billy Kilis; Harrychoon Angmalisang; Jocke Rapar; Nontje Sangi
JURNAL EDUNITRO Jurnal Pendidikan Teknik Elektro Vol. 3 No. 2 (2023): October Issue
Publisher : Department of Electrical Engineering Education, Faculty of Engineering, State University of Manado

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53682/edunitro.v3i2.6324

Abstract

This study aims to analyze and design electrical lighting installations in the Unima library building that meet PUIL 2011 standards. The data analysis technique used is inductive data analysis. Inductive data analysis encourages researchers to solve certain cases by testing a theory. The lighting installation design for the Manado State University Library building uses a formula to find the number of light points needed in lux units based on needs, assuming the recommended lamp is 150 watts. In book room 1, after rounding, the lights needed in book room 1 are 13. In book room 2, after rounding, the lights needed in book room 2 are 23. In book room 3, after rounding, the lights needed in book room 3 are 26 lights. In reading room 1, after rounding up, the lights needed in reading room 1 are 12. In reading room 2, after rounding up, the lights needed in reading room 2 are 13. In the administration room, after rounding, the lights needed in the administration room are 4 lights. They are recommended in the admin room, using 100 watts. For direct lighting systems with bright-coloured ceilings and walls, the coefficient value is 50%–65%.
Analisis dan Perancangan Instalasi Penerangan Gedung Perpustakaan Universitas Negeri Manado Kluivert Abast; Billy Kilis; Harrychoon Angmalisang; Jocke Rapar; Nontje Sangi
JURNAL EDUNITRO Jurnal Pendidikan Teknik Elektro Vol. 3 No. 2 (2023): October Issue
Publisher : Department of Electrical Engineering Education, Faculty of Engineering, State University of Manado

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53682/edunitro.v3i2.6324

Abstract

This study aims to analyze and design electrical lighting installations in the Unima library building that meet PUIL 2011 standards. The data analysis technique used is inductive data analysis. Inductive data analysis encourages researchers to solve certain cases by testing a theory. The lighting installation design for the Manado State University Library building uses a formula to find the number of light points needed in lux units based on needs, assuming the recommended lamp is 150 watts. In book room 1, after rounding, the lights needed in book room 1 are 13. In book room 2, after rounding, the lights needed in book room 2 are 23. In book room 3, after rounding, the lights needed in book room 3 are 26 lights. In reading room 1, after rounding up, the lights needed in reading room 1 are 12. In reading room 2, after rounding up, the lights needed in reading room 2 are 13. In the administration room, after rounding, the lights needed in the administration room are 4 lights. They are recommended in the admin room, using 100 watts. For direct lighting systems with bright-coloured ceilings and walls, the coefficient value is 50%–65%.