Entidhar Mhawes Zghair
Middle Technical University

Published : 3 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 3 Documents
Search

Enhancement of medical images diagnosis using fuzzy convolutional neural network Huda Ali Mahdi; Mohamed Ibrahim Shujaa; Entidhar Mhawes Zghair
Bulletin of Electrical Engineering and Informatics Vol 12, No 6: December 2023
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v12i6.5729

Abstract

Brain diseases are primarily brought on by abnormal brain cell growth, which can harm the structure of the brain and eventually result in malignant brain cancer. Major challenges exist when using a computer aided diagnosis (CAD) system for an early diagnosis that enables decisive treatment, particularly when it comes to the accurate detection of various diseases in the pictures for magnetic resonance imaging (MRI). In this study, the fuzzy convolutional neural networks (FCNN) were proposed for accurate diagnosis of brain tumors (glioma, meningioma, pituitary and non-tumor) which is implemented using Keras and TensorFlow. This approach follows three steps, training, testing, and evaluation. In training process, it builds a smart model and the structure consists of seven blocks (convolution, rectified linear unit (ReLU), batch normalization, and max pooling) then use flatten, fuzzy inferences layer, and dense layer with dropout. An international dataset with 7,022 brain tumor MRI images, was tested. The evaluation model attained a high performance with training accuracy of 99.84% and validation accuracy is 98.63% with low complexity and time is 58 s per epoch. The suggested approach performs better than the other known algorithms and may be quickly and accurately used for medical picture diagnosis.
Performance and quality analysis of brain MRI image transmission over free-space optical communication systems under severe atmospheric conditions Entidhar Mhawes Zghair; Seham Hashem; Ali Hammadi
International Journal of Electrical and Computer Engineering (IJECE) Vol 16, No 5: October 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijece.v16i5.pp2526-2536

Abstract

Reliable transfer of brain magnetic resonance imaging (MRI) data over atmospheric free-space optical (FSO) links is a key enabler of telemedicine, yet conventional FSO studies judge link quality by communication metrics such as the bit error rate (BER) alone, which cannot guarantee the structural and contrast fidelity that diagnosis demands. This study proposes a quality-aware FSO transmission framework for brain MRI in which link performance is assessed jointly through BER, peak signal-to-noise ratio (PSNR), and the structural similarity index (SSIM). A physical-layer FSO channel is modelled in OptiSystem 20 and co-simulated with MATLAB R2023b, which performs image serialization, reconstruction, and quality analysis. Thirty axial T2-weighted slices (256×256, 8-bit) from the public IXI dataset are transmitted at 1550 nm over clear-air, rain, and fog channels at 500, 1000, and 2000 m. Adopting conservative diagnostic thresholds of PSNR ≥ 30 dB and SSIM ≥ 0.85, the link is diagnostically usable in clear air at all tested distances (PSNR = 42.1 dB, SSIM = 0.98 at 500 m) and in rain up to 2000 m (PSNR ≥ 31.2 dB), whereas fog degrades quality below the thresholds at every distance, reaching PSNR = 22.7 dB and SSIM = 0.68 at 2000 m. A concatenated forward-error-correction (FEC) scheme is then shown to restore diagnostic quality under fog up to 1000 m, extending the usable fog range, while 2000 m remains infeasible and motivates hybrid FSO/RF operation. The framework provides quantitative deployment limits for FSO-based medical image transport.
Heart Disease Classification Using CatBoost Tuned by Harris Hawks Optimization Seham Ahmed Hashem; Ahmed Aizaldeen Abdullah; Entidhar Mhawes Zghair
Buletin Ilmiah Sarjana Teknik Elektro Vol. 8 No. 6 (2026): December
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/biste.v8i6.16831

Abstract

Reliable heart-disease classification remains an important biomedical engineering problem because performance on small structured medical datasets is sensitive to preprocessing, validation design, class distribution, and hyperparameter selection. This study aims to develop a leakage-safe framework for binary heart-disease classification using the processed Cleveland subset of the UCI Heart Disease dataset. The research contribution is the integration of CatBoost with Harris Hawks Optimization to tune discrete and continuous hyperparameters while preserving strict separation between model selection and final testing. The framework also provides an explicit workflow to improve transparency and reproducibility. The dataset contains 303 patient records and 13 predictive attributes and was divided using an 80:20 stratified train-test split. Five-fold stratified cross-validation was applied only within the training subset to evaluate candidate configurations. Missing-value handling, categorical-feature processing, and class-weight optimization were restricted to training data, while the held-out test subset remained isolated until final evaluation. The optimized model achieved 97.12% accuracy, 96.80% precision, 97.35% recall, 96.90% specificity, a 97.07% F1-score, and a 98.40% area under the receiver operating characteristic curve. It produced higher point estimates than the evaluated conventional classifiers, default CatBoost, random-search CatBoost, and grid-search CatBoost. However, the 1.22-percentage-point accuracy improvement over grid-search CatBoost represents a numerical benchmark advantage rather than statistically confirmed superiority. These findings indicate that Harris Hawks Optimization can improve CatBoost configuration for structured cardiovascular data. Nevertheless, external multi-center validation, repeated statistical evaluation, calibration analysis, and prospective clinical assessment are required before practical deployment.