Mustika Sari
ITS PKU Muhammadiyah Surakarta

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Hubungan Indeks Massa Tubuh Dengan Kejadian Shivering Post Anestesi Spinal Pada Pasien Sectio Caesarea Di RSKDIA Siti Fatimah Makassar Muhammad Hafiduddin; Mustika Sari; Asdar Asdar
Journal Pharma Saintika Vol. 4 No. 2 (2021): April : Jurnal Pharma Saintika
Publisher : Program Studi DIII Farmasi Akademi Farmasi Dwi Farma

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51225/jps.v4i2.36

Abstract

Background back : Shivering is frequent complications _ occur on technique spinal anesthesia . Index mass body low will more easy lost hot so that body compensate to drop temperature body for increase production hot and is factor risk happening possible hypothermia _ trigger incident intraoperative shivering Purpose : Knowing connection index mass body with incident shivering on patient Sectio Caesarea with spinal anesthesia , knowing frequency index mass body and shivering incident know _ level closeness connection as well as knowing factor risk index mass body with incident shiveringMethod : Observation analytic with approach cross sectional . Technique taking sample use purposive sampling. Sample study as many as 66 respondents and use test Chi Square.Result : Index mass body not enough with incident shivering as many as 9 (90%) respondents while those who are not shivering are 1 (10%) respondents , index mass body more with incident shivering 6 (20.7%) respondents while those who don't shivering 23 (79.3%) respondents , and index mass normal body with incident shivering 19 (70.4%) respondents while those who don't shivering 8 (29.6%) respondents .. Results test statistics use test Chi Square that is value 0.000 ( < 0.05 ) .Conclusion : There is connection Among index mass body with incident shivering on patient Sectio Caesarea with spinal anesthesia . Respondent part big have index mass body partially normal big experience shivering . Closeness level connection currently because other factors that can influence Shivering incident other than index mass body like , amount bleeding , duration of operation , length of fasting , temperature room and temperature preoperative body . _ Respondent with index mass body thin more risky experience intraoperative shivering _.
Efektifitas Loading Cairan Koloid Terhadap Kejadian Hipotensi Pada Pasien Sectio Caesarea Dengan Spinal Anestesi Di RSD Dr A.Dadi Tjokrodipo Bandar Lampung Mustika Sari; Galih Pria Pambayun; Ambar Samekto
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia Vol. 1 No. 3 (2021): NOVEMBER : Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Publisher : Lembaga Pengembangan Kinerja Dosen

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikki.v1i3.2220

Abstract

RSD Dr.A. Dadi Tjokrodipo Bandar Lampung, sectio caesaria patients in the last 3 months of 2021 totaled 40 patients. Hypotension or decrease in Mean Arterial Pressure (MAP) in caesarean section often occur consequence spinal anesthesia due to overall blockade effect on the sympathetic nervous system . Study this aim for This study aims to determine the effect of loading colloid fluid in sectio caesarea patients with spinal anesthesia. Method study qualitative with a descriptive research design is a research that tends to use analysis . Population study 40 patients sectio caesarea with spinal anesthesia at Dr A. Dadi Tjokrodipo Hospital Bandar Lampung with amount sample of 8 patients. From result study "Effectiveness of Loading Colloidal Fluids Against Hypotension in Sectio Caesarea Patients With Spinal Anesthesia at Dr A. Dadi Tjokrodipo Hospital Bandar Lampung" could obtained results that Patient Sectio Caesarea performed Partial spinal anesthesia big experience hypotension (87.5%) due to effect of spinal anesthesia , so that required gift fluid colloid for raise pressure blood . Effect gift fluid colloid on patient cesarean section hypotension really mean for normalize return pressure blood patients (75%). Based on results Paired Samples T-Test statistical test obtained value of Sig.(2-tailed) = 0.001 or < 0.05 which means there is significant difference on the Mean Arterial Pressure (MAP) before and after gift fluid colloid on patient sectio caesarea with spinal anesthesia at Dr A. Dadi Tjokrodipo Hospital, Bandar Lampung