Claim Missing Document
Check
Articles

Found 2 Documents
Search

Enhancing the Performance of Power System under Abnormal Conditions Using Three Different FACTS Devices Ibram Y. Fawzy; Mahmoud A. Mossa; Ahmed M. Elsawy; Ahmed A. Zaki Diab
International Journal of Robotics and Control Systems Vol 4, No 1 (2024)
Publisher : Association for Scientific Computing Electronics and Engineering (ASCEE)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31763/ijrcs.v4i1.1229

Abstract

In this paper, a comparison between Flexible Alternating Current Transmission System (FACTS) devices including Static Synchronous Compensator (STATCOM), Static Synchronous Series Compensator (SSSC) and Unified Power Flow Controller (UPFC) for providing a better adaptation to changing operating conditions and improving the usage of current systems. The power system using FACTS devices is presented under different conditions such as single phase fault and three phase fault. A digital simulation using Matlab/Simulink software package is carried out to demonstrate the better performance including the voltage and the current of the presented system using FACTS that located between buses B1 and B2 under different faults types. The results obtained investigate that the presented system gives better response with FACTS as compared to not using them under abnormal conditions besides, the UPFC gives better performance of power system under several faults as compared to STATCOM or SSSC as It can absorb reactive power in a manner which significantly reduced the fault current. It is demonstrated that UPFC can reduce the peak fault current at bus B1 ‎to 63.85% of its value without ‎using FACTS devices under line to ground fault and 79.18% under three line to ‎ground fault whereas STATCOM and SSSC reduce it ‎to (75.21, 94.35%) and (75.40, 94.68%), respectively.
Utilizing Two Maximum Power Point Tracking Techniques with an Integrated DC-DC Boost Converter for Controlling a Grid-Connected Photovoltaic System Haitham Ibrahim Elbahat; Ibram Y. Fawzy; Ahmed A. Zaki Diab; Hamdy Sultan; Ahmed Kassem; Alfian Maarif; Mahmoud A. Mossa
Buletin Ilmiah Sarjana Teknik Elektro Vol. 8 No. 2 (2026): April
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/biste.v8i2.15933

Abstract

This paper focuses on the comparison of maximum power point tracking ‎‎(MPPT) techniques for photovoltaic (PV) system that is interfaced with the ‎utility ‎grid via a three-phase voltage source inverter (VSI). Two algorithms for ‎MPPT ‎are presented: the Perturb and Observe (P&O) technique and the ‎Incremental Conductance (INC) algorithm, ‎which employ a DC-DC boost ‎converter.‎ The algorithms are designed to optimize the capture of power produced by the PV system by measuring the PV output power and adjust the converter’s duty cycle. The VSI in the system handles the conversion from DC to AC. It employs both an internal control loop and an external control loop to maintain the stability of the DC-link voltage and to ensure synchronization with the grid. The grid synchronization of system involves the use of Phase-Locked Loops (PLL) to achieve high accuracy in dynamic conditions. The MPPT algorithms are implemented purely in a simulated environment using the Matlab/Simulink package to illustrate the advantages of the presented MPPT methods in comparison to operating without MPPT under different meteorological conditions. The PV array simulation generally employs monocrystalline modules. The electrical parameters of the system comprise the maximum power point voltage (Vmpp), maximum power point current (Impp), open-circuit voltage (Voc), and short-circuit current (Isc). The system initiates operations under standard test conditions (STC) of 25°C and 1000 W/m² during the simulation, followed by variations in irradiance (G) and temperature (T) over time. The findings‎ indicate that the P&O technique effectively tracks the maximum power point (MPP) and facilitates the extraction of further power throughout fluctuations under various meteorological conditions. Furthermore, the INC algorithm is determined to be more effective for achieving MPPT in relation to both the P&O method and the absence of MPPT under dynamic as well as steady-state conditions‎. The INC algorithm is shown to increase the PV output power at STC by 5.24% without utilizing ‎MPPT, whereas the P&O algorithm achieves an enhancement of 3.24%.‎ The results also reveal that the INC technique exhibits the highest performance, achieving approximately 99.72% efficiency, whereas P&O reaches nearly 97.62% efficiency at STC.