Muhammad Alqaaf
Nara Institute of Science and Technology

Published : 3 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 3 Documents
Search

Morphological features of lung white spots based on the Otsu and Phansalkar thresholding method Retno Supriyanti; Syadzwina Luke Dzihniza; Muhammad Alqaaf; Muhammad Rifqi Kurniawan; Yogi Ramadhani; Haris Budi Widodo
Indonesian Journal of Electrical Engineering and Computer Science Vol 33, No 1: January 2024
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v33.i1.pp530-539

Abstract

COVID-19 is a disease that causes respiratory system disorders, so various tests are needed. One of them uses a chest X-ray or thorax. A chest X-ray will depict the lungs as a whole so that patches like white shadows will be visible. In this study, the number of lung areas and white spots can be observed and detected using segmentation techniques in image processing. But before entering the segmentation stage, the image will go through the preprocessing stage using the tri-threshold fuzzy intensification operators (fuzzy IO) method. It then segmented the lungs using the Otsu method by changing the digital image from grey to black and white based on comparing the threshold value with the pixel colour value of the digital image. Then, further segmentation was carried out using the Phansalkar method to detect and simultaneously count the number of white spots. Referring to the experiments we have carried out, Otsu Phansalkar's segmentation performance promises to be developed further.
Deep learning-based cervical cancer detection via colposcopy images integrated into an Android mobile application Retno Supriyanti; Arsil Kultura Anzil; Yogi Ramadhani; Suroso Suroso; Wahyu Widanarto; Muhammad Alqaaf; Kartika Dwi Hapsari; Futiat Diana Kartika
IAES International Journal of Artificial Intelligence (IJ-AI) Vol 15, No 1: February 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijai.v15.i1.pp338-349

Abstract

Cervical cancer is a form of cancer that develops in the cells of the cervix, the lower part of the uterus that connects the uterus to the vagina. Early detection is essential for improving the chances of recovery from cervical cancer. One method for early detection is colposcopy image analysis, a medical procedure that examines the cervix and captures images for evaluation. These images were analyzed to observe color changes after the visual inspection with acetic acid (VIA) process. However, this analysis requires experienced and specially trained medical personnel. To address this challenge, a system that can automatically classify cervical cancer images is needed. Therefore, researchers proposed designing and developing an Android mobile application to enable early detection of cervical cancer using the convolutional neural network (CNN) algorithm. The CNN model was tested using test data to evaluate its performance. The optimized CNN model utilizing the ResNet50 architecture achieved 86% test accuracy, 85% precision, and 87% recall. The test results indicate that the model's accuracy is consistent before and after its implementation on the mobile application, confirming the effectiveness of both the model and its implementation as diagnostic tools.
Lanthanum-doped reduced graphene oxide modified screen-printed carbon electrode for lactic acid sensing Retno Supriyanti; Rafi Satria Dwi Awanda; Wahyu Widanarto; Dina Rahmawati; Madya Ardi Wicaksono; Syafrudin Rais Akhdan; Muhammad Alqaaf
International Journal of Reconfigurable and Embedded Systems (IJRES) Vol 15, No 3: November 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijres.v15.i3.pp671-682

Abstract

This study develops a high-performance lactic acid sensor by modifying screen-printed carbon electrodes (SPCEs) with lanthanum-doped reduced graphene oxide (La-rGO). To enable portable and wearable applications, the sensor is integrated into an internet of things (IoT) architecture utilizing a micro-power analog front-end (AFE), an ESP32-C6 controller, and a field-programmable gate array (FPGA) coprocessor for dynamic calibration. Electrochemical characterization demonstrated a high sensitivity of 20.36 µA·mM⁻¹·cm⁻², surpassing unmodified SPCEs. Under optimal conditions, the sensor achieved a limit of detection (LOD) of 13.58 mM and a limit of quantification (LOQ) of 45.28 mM. Furthermore, hardware evaluation showed the FPGA executes temperature compensation with an ultra-low latency of 1.80 µs. A hybrid duty-cycling strategy restricts the average current to 1.85 mA, allowing over 172 hours of continuous operation on a 320 mAh battery. These results demonstrate the hardware-accelerated, IoT-enabled La-rGO/SPCE platform's potential for continuous, non-invasive epidermal sweat analysis.