Muhammad Mahmud
Department of Electrical Engineering, Ahmadu Bello University, Zaria, Nigeria

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Harmonic Mitigation in Inverter Circuits Through Innovative LC Filter Design Using PSIM Habib Muhammad Usman; Muhammad Mahmud; Sani Saminu; Salihu Ibrahim
Jurnal Ilmiah Teknik Elektro Komputer dan Informatika Vol. 10 No. 1 (2024): March
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26555/jiteki.v10i1.28398

Abstract

The increasing use of renewable energy sources, such as solar and wind power, and the growing ubiquity of High Voltage Direct Current (HVDC) transmission systems to improve power transmission efficiency are the main factors behind the increased deployment of inverter circuits. However, high harmonic distortions in the resultant sine wave are a major problem for inverter circuits and could jeopardise circuit efficiency if left unchecked. This study presents a novel, affordable, and effective LC filter intended to remove almost all harmonic content from inverter circuits. The study uses PSIM software to model, design, and control a three-phase inverter. Starting with the DC power supply, the study makes use of effective three-legged IGBT (insulated gate bipolar transistor) semiconductor devices as switch elements due to their high and current rating as well as faster operation. The switching gate pulses that turn inverter switches on and off at regular 60-degree intervals are produced by the pulse controller that controls the switches. This study's results show that the innovative LC filter in the inverter significantly reduced total harmonic distortion (THD) in all phases of the power signal. Specifically, THD decreased from 37.68% to 0.47% in the red phase, from 37.69% to 0.48% in the blue phase, and from 37.71% to 0.48% in the yellow phase. This reduction results in a notable improvement in power quality in all phases of the signal. Additionally, there is a noticeable increase in voltage magnitude, stabilizing and raising levels from 17.92 V to 23.83 V in the red phase, 17.93 V to 23.81 V in the blue phase, and 17.83 V to 23.81 V in the yellow phase due to the LC filter. These results demonstrated the effectiveness of the LC filter-equipped inverter for industrial, HVDC, and renewable energy applications.
WIND-POWERED AGRICULTURE: ENHANCING CROP PRODUCTION AND ECONOMIC PROSPERITY IN ARID REGIONS Habib Muhammmad Usman; Muhammad Mahmud; Madaniyyu Sulaiman Yahaya; Sani Saminu
Elektrika Vol. 16 No. 1 (2024): April 2024
Publisher : Universitas Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26623/elektrika.v16i1.8999

Abstract

Over an extended duration, small-scale farmers have been contending with the persistent issue of electricity scarcity, which adversely affects crop production, particularly during dry seasons. The dependence on generators, despite being expensive and environmentally harmful due to oil spillage and Carbon dioxide (CO2) emissions, remains a prevalent yet unsustainable solution. Wind energy emerges as a promising alternative with diverse benefits for farmers, addressing concerns related to irrigation, storage, and water management, ultimately leading to significant yield increases during dry periods. This study investigates the performance of a small-scale wind energy conversion system tailored for the irrigation needs of farmers in arid regions, focusing on Zaria Local Government, Kaduna State, Nigeria as a case study. Utilizing wind speed data from the Nigeria Meteorological Agency (NIMET), the system's electrical parameters, including voltage, current, frequency, and power, were analyzed to assess fluctuations resulting from wind speed variations. Results show significant variability in electrical parameters: wind speed ranged from 3.10 m/s to 9.83 m/s, resulting in fluctuations in generated voltage (98 volts to 250 volts), current (51 amps to 103 amps), frequency (39 Hz to 65 Hz), and power (5.1 kW to 20.6 kW). Converter systems were found effective in stabilizing output for grid integration: the AC/DC converter converted fluctuating AC signals into stable DC output (200 volts, 93 amps), while the subsequent DC/AC inverter produced non-fluctuating AC output (voltage: 200 volts, current: 92 amps, frequency: 50 Hz, power: 18.3 kW). These findings emphasize feasibility of implementing wind energy solutions in remote agricultural areas.