Fernandiaz, Revi
Jurnal Online Mahasiswa (JOM) Bidang Perikanan dan Ilmu Kelautan

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

The effectiveness of sago liquid waste as nutrient of Chlorella sp. culture in the peat water media Fernandiaz, Revi; Harahap, Sampe
Jurnal Online Mahasiswa (JOM) Bidang Perikanan dan Ilmu Kelautan Vol 4, No 1 (2017): Wisuda Februari Tahun 2017
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Perikanan dan Ilmu Kelautan

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Sago liquid waste is rich in micro and macro nutrient that can be used for growing Chlorella sp. To understand the effectiveness of the waste as a nutrient source to grow Chlorella sp., a study was conducted from November – December 2016. Different amount of sago liquid waste was added to 3L of peat water, they were P0(0%), P1(5%), P2(15%) and P3 (25%) of peat water volume. The Chlorella sp. was culture for 11 days. Parameters measured were the abundance and biomass of Chlorella sp., nitrate and phosphate concentration, dissolved oxygen, pH and temperature. Results shown that the best growth of Chlorella sp. was in the P1(5%), the abundance was 2,768,000 cells/ml and the biomass was 0.28 g/L. During the research, the nitrate and phosphate concentration reduced, from 0.5575 to 0.2540 mg/L and from 0.9358 to 0.3142 mg/L respectively. This fact indicates that the nutrients have been used for Chlorella sp. growth. Based on data obtained, it can be concluded that the sago liquid waste can be used as nutrient source for growth Chlorella sp. Keywords : Sago liquid waste, nutrient, growth, Chlorella sp.
Modeling Of Oil Flows In Langgak Field Pipeline Fernandiaz, Revi; Amri, Idral; Utama, Panca Setia
Journal of Earth Energy Engineering Vol 8 No 1 (2019): APRIL
Publisher : Pekanbaru Riau: Program Studi Teknik Perminyakan FT Universitas Islam Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (574.685 KB) | DOI: 10.25299/jeee.2019.vol8(1).2557

Abstract

Abstract Congeal in the pipeline is one of the biggest problems faced by PT.SPR Langgak in piping crude oil from production wells to oil processing unit caused by decreasing oil temperature. The purpose of this study is to study the effect of environmental temperature on fluid temperature in the pipeline, study the effect of wind speed on fluid temperature in the pipeline and to determine the location of the occurrence of congeal in PT.SPR Langgak pipeline. Determining the location of the occurrence of congeal using the model T with analytical methods in the Matlab software is by entering parameters of pipe temperature, viscosity, density, fluid velocity, wind speed and environmental temperature. The congeal location was determined by model T obtained in the Zone C pipeline distance 44.9-449m with the average error model T is 1.88%. This model T can be applied provided the paraffin content is 15-60% and the pipe characteristics (pipe thickness, pipe diameter and pipe material) are the same.