DESKRIPSI JUMLAH LEUKOSIT PADA PENDERITA KANKER SERVIKS SEBELUM DAN SESUDAH RADIOTERAPI cicillia artitin
Jurnal Ilmiah Kesehatan Vol 22 No 03 (2023): Jurnal Ilmiah Kesehatan terbitan Desember Volume 22 Nomor 03 Tahun 2023
Publisher : UIMA Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33221/jikes.v22i03.2175

Abstract

Radioterapi digunakan sebagai terapi kuratif pada kanker serviks, dimana total dosis radiasi diberikan 40-50 Gy per fraksi seminggu, dosis sekitar 0,5 Gy sudah dapat menyebabkan penurunan proses pembentukan sel-sel darah sehingga jumlah sel darah akan menurun. Leukopenia dapat terjadi setelah radioterapi karena sel leukosit sangat radiosensitif. Sel leukosit yang didalamnya terdapat sel limfosit yang berfungsi sebagai pertahanan. Apabila berkurang pertahanan tubuh terhadap penyakit menjadi lemah Penelitian ini bertujuan untuk melihat gambaran jumlah leukosits ebelum dan setelah radioterapi. Jenis penelitian kuantitatif dengan metode pengambilan data secara restropektif dilakukan di Rumah Sakit Umum Pusat Dr.M. Djamil padang pada bulan April-Juni 2022 dengan jumlah populasi 25 dengan teknik purposive sampling, sehingga sampel pada penelitian ini adalah 10 orang pasien, kemudian data diolah dengan menggunakan program SPSS dengan analisis univariat. Hasil penelitian menyatakan bahwa jumlah leukosit normal sebelum penyinaran sebanyak 40,0% dan jumlah leukosit yang tidak normal sebanyak 70,0%. Jumlah leukosit normal pada minggu ke 1 sebanyak 60,0% dan jumlah leukosit yang tidak normal sebanyak 40,0%. Pada minggu ke 2 jumlah leukosit normal sebanyak 80,0% dan jumlah yang tidak normal sebanyak 20,0%. Pada mingguke 3 jumlah leukosit normal sebanyak 70,0% dan yang tidak normal sebanyak 30,0%. sehingga dapat disimpulkan bahwa dosis radiasi yang telah diberikan selama 3 minggu yaitu 20 Gy menurunkan jumlah leukosit.
UJI KESAMAAN BERKAS KOLIMATOR DENGAN VARIASI JARAK FFD (FOCUS FILM DISTANCE) PADA PESAWAT SINAR-X Cicillia Artitin; Chairun Nisa; Oktavia Puspita Sari; Neneng Anjarwati
Jurnal Kesehatan Saintika Meditory Vol 7, No 2 (2024): November 2024
Publisher : STIKES Syedza Saintika Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30633/jsm.v7i2.2849

Abstract

The collimator is a part of the x-ray device that has the function of regulating the size of the field. If this field is not aligned, the anatomy that should enter the irradiation field is not exposed to radiation. The large number of exposures performed can result in a mismatch between the area of the irradiation field and the X-ray beam produced. Distance variations are used to determine the suitability or value of the shift in the collimator field area tested. This study aims to determine the feasibility of a collimator on an X-ray plane by determining the similarity of the collimated beam with the X-ray beam.The type of research used is quantitative with experimental methods in the radiology installation of Andalas University Hospital Padang in August 2023 with variations of FFD 90 cm, 100 cm, 110 cm, and 120 cm. The measuring instrument used collimator test tool with collimation size 14x18 cm using small focal spot and large focal sp-axis (horizontal) and Y-axis (vertical) values by not exceeding 3% of FFD (ΔX + ΔY ≤ 3% of FFD).The test results of the collimator beam similarity test with FFD distance variations that comply with the tolerance limit ≤ 2% FFD are at FFD 100 cm, 110 cm, and 120 cm when using a small focal spot. While those that do not match or exceed the tolerance limit ≤ 2% FFD are FFD 90 cm small focal spot, FFD 90 cm, 100 cm, 110 cm, and 120 cm when using a large focal spot. Collimation that is feasible to use in the radiographic imaging process on a small focal spot with a distance (FFD) starting from 100 cm. The large focal spot is not feasible to use and needs to be improved.Keywords: Conformity test, Beam collimation, FFD distance variation