Burlian Mughnie
Unknown Affiliation

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Analisis Pemeriksaan MRI Brain Pada Kasus Vertigo Di Instalasi Radiologi Rumah Sakit Balimed Denpasar Rama Yeni Ines Sirait; Ni Putu Jeniyanthi; Triningsih Triningsih; Burlian Mughnie
Jurnal Ilmu Kesehatan dan Gizi Vol. 2 No. 1 (2024): Januari : Jurnal Imu Kesehatan dan Gizi
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikg.v2i1.2101

Abstract

The background of this research is that vertigo is a symptom caused by disturbances in body balance due to the different locations of the lesions. Vertigo is not a disease but a symptomatic condition of vestibular system disorders. Evaluation of patients with audiovestibular disorders, sensorineural hearing disorders, tinnitus, and vertigo . Brain MRI is used to evaluate patients with audiovestibular dysfunction, including sensorineural hearing loss, tinnitus, and vertigo. This research method is descriptive qualitative research with a case study approach using a research design, namely observation, interviews and documentation which aims to find out why the T2 MATRIX 3D SPAIR sequence is needed for MRI brain examinations in vertigo cases at the Radiology Installation at Balimed Hospital, Denpasar. The data collection method was obtained using 3 Brain MRI patients, 3 radiology specialists and 3 radiographers. The results of this research show that the Magnetic Resonance Imaging (MRI) brain examination procedure in Vertigo cases at the Radiology installation at Balimed Hospital Denpasar uses the additional T2 MX3D SPAIR sequence for Vertigo cases because this sequence is able to show the nerve fibers in the brain. The conclusion is that the Magnetic Resonance Imaging (MRI) brain examination procedure in Vertigo cases at the Radiology installation at Balimed Hospital Denpasar does not require special preparation, only more attention is paid to the patient's condition, whether they are wearing braces or dentures because the two tools used will interfere with the results of the MRI image used. The reason for using the T2 MX3D SPAIR sequence is with the aim of adding diagnostic information from the image quality results in order to establish a diagnosis of many neurological disorders or nerve fibers, one of which is Vertigo.
Analisa Quality Assurance (QA) Daily Pada Pesawat Linac Di Instalasi Onkologi Radiasi RSUP Persahabatan Ningsih, Irianti Fitri; Kadek Yuda Astina; Burlian Mughnie
Kappa Journal Vol 9 No 1 (2025): April
Publisher : Universitas Hamzanwadi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29408/kpj.v9i1.27617

Abstract

Linear Accelerator (Linac) plays a critical role in external radiotherapy for cancer treatment, requiring stringent quality assurance (QA) measures to ensure accuracy and safety. This study focuses on analyzing the implementation of daily QA for the Elekta Prices Linac model Precise at the Radiation Oncology Unit of RSUP Persahabatan. Conducted from May to July 2024, the analysis evaluates four key parameters: Laser Localization, Optical Distance Indicator (ODI), Door Interlock, and Audiovisual Monitor. The results demonstrate that all parameters met the tolerance limits set by AAPM Task Group 142, ensuring the Linac operates safely and effectively. Consistent implementation of daily QA is shown to detect potential deviations early, safeguarding both patient and staff safety while maintaining treatment quality.