Occupational Safety And Health System For Radiation Workers In The Conventional Radiology Room Rumkit Tk II Pelamonia Makassar A. AR. Rakhmansya Iskandar; Muh. Rusli; Cisya Fadhilah Nur Sadiyyah
International Journal of Medicine and Health Vol. 2 No. 4 (2023): December : International Journal of Medicine and Health (IJMH)
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/ijmh.v2i4.2929

Abstract

K3 system for radiation workers in the conventional radiology room at TK II Pelamonia Makassar. The aim of this research is to determine the completeness and compliance of radiation workers in implementing K3. The K3 system in the Conventional Radiology Room at Tk II Pelamonia Makassar is to use PPE aprons when the radiation is carried out. The PPE apron is used only if the patient requires assistance during the radiation. Radiographers also carry out occupational safety and health training and carry out routine health checks carried out by hospitals. When the radiation is carried out, the radiographer stands behind a wall/screen coated with Pb. Radiographers also always use TLD when on duty or carrying out radiation.
Efektivitas Rancang Bangun Alat Fikasasi Pada Pemeriksaan Babygram di Radiologi Rumah Sakit TK.II Pelamonia Makassar A. Ar. Rakhmansya Iskandar; Wahyu Wahyu
Quantum Wellness : Jurnal Ilmu Kesehatan Vol. 1 No. 2 (2024): Juni: Quantum Wellness : Jurnal Ilmu Kesehatan
Publisher : Lembaga Pengembangan Kinerja Dosen

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.62383/quwell.v1i2.789

Abstract

A fixation device is a tool used to make it easier for a radiographer to carry out examinations in radiology. Bontranger, 2014 The use of this tool has a specific nature, this tool can only be used for certain examinations, for example the Babygram examination. The aim of this research is to determine the effectiveness of the design and construction of fixation equipment in the Radiology Installation at TK.II Pelamonia Makassar Hospital in March – May 2024. The independent variables in this research are the aspects of equipment feasibility, equipment safety, equipment function and radiographic results. This type of research is Quantitative Descriptive Analytical. The data collection technique uses a questionnaire. The population and sample were 11 respondents, namely 10 radiographers and 3 radiology specialists. The sampling technique was carried out by accidental sampling. Data analysis uses descriptive analysis and is presented in the form of a frequency distribution table. Based on the research results, it can be concluded that the design of the Babygram fixation tool from the feasibility test aspect of the tool was obtained as Very Suitable (100%) for use and Fairly Good (100%) set on the examination table. For the safety aspect test results, the results were quite safe (100%) for supporting the baby and the results were very safe (100%) for the quality of the materials used. Meanwhile, for the test results of whether the tool can be used, the results obtained are very suitable (100%), it can be adjusted and adjusted to the shape and size of the baby's body, but quite a long time (100%) is needed during the examination. The radiographic test results obtained were Very Good (100%) showing anatomical structures and None (100%) showing radiographic results free from artifacts. It is best to have a fixation tool available in Radiology because it really helps radiographers treat non-cooperative patients and with a fixation tool the time required is very faster compared to without using a fixation tool.