Claim Missing Document
Check
Articles

Found 2 Documents
Search

Oxyuris spp. Infection in Green Iguana (Iguana iguana) Under Different Cage Types kusumarini , shelly; Rafi Dzakir Ghalib; Garvasilus Privantio Tegar Virgiawan Huler; Reza Yesica; Nanis Nurhidayah; Haris Muhamad; Nuha Fairusya
Journal of Parasite Science Vol. 8 No. 1 (2024): Journal of Parasite Science
Publisher : Universitas Airlangga

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20473/jops.v8i1.54142

Abstract

The caging system becomes one of the most crucial points in the green iguana (Iguana iguana) husbandry practice since some pathogens are transmitted through ingesting contaminated feed or water in the cage. One of the most common health problems in the green iguana is caused by infection of the gastrointestinal nematode (GIN), Oxyuris spp. Here, we conducted a study to identify Oxyuris spp. infection in the green iguana under different cage types in Malang Raya, East Java. A total of 40 fecal samples were collected and examined through flotation and modified McMaster techniques from three cage types, namely loose cage / extensive (n= 7), terrarium (n= 13), and iron-based cage (n= 20). The results showed that all green iguanas are infected with Oxyuris spp. (40/40 or 100 % prevalence). The highest mean egg per gram (EPG) was found in the green iguana which kept in a loose cage / extensive (mean EPG [CI 95 %] = 14 799.21 [14 442.05 – 15 156.37]), followed by terrarium (mean EPG [CI 95 %] = 8 763.80 [8 436.30 – 9 091.30]), and iron-based cage (mean EPG [CI 95 %] = 1 433.42 [1 303.79 – 1 563.05], respectively. At the same time, there is a significant relationship (P<0,05) between the type of cage and the infection rate of Oxyuris spp. According to this result, we recommend an iron-based cage with routine daily cleaning as prevention for Oxyuris spp. infection among the green iguana.
VERIFIKASI PENGUKURAN RADIOAKTIVITAS 153Sm MENGGUNAKAN DOSE CALIBRATOR MULTITIPE Ligwina Dita Pertiwi; Maskur Maskur; Yanto Yanto; Nuha Fairusya; Nuri Jannati Wahyu Ekaningsih
Urania: Jurnal Ilmiah Daur Bahan Bakar Nuklir Vol. 29 No. 2 (2023): Urania : Jurnal Ilmiah Daur Bahan Bakar Nuklir
Publisher : Badan Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/urania.2023.29.2.6838

Abstract

Measurement verification is crucial to ensure measurement results validity. In this study, we have done verification on 153 Sm radioactivity using five different types of dose calibrators dose calibrator Atomlab 100, Atomlab 300, Atomlab 400, Atomlab 500, and Capintec CRC-tR5. The parameters of verification process including accuracy, precision, linerity, Limit of Detection (LOD), and Limit of Quantification (LOQ). The dose calibrator Atomlab 300 was established as the standard instrument to examine the others type of dose calibrator accuracy. Verification results showed all the instruments have an error of less than 3%. However, the t-test results exhibited only the dose calibrator Atomlab 400 that had tvalue less than the corresponding ttable value. In contrast, Atomlab 100, Atomlab 500, and Capintec CRC tR5 produced a tvalue greater than a ttable value. In the precision test, all types of dose calibrator gave a satisfactory precision results. All five-dose calibrators demonstrated good linearity for measuring radioactivity within the range of 20-140 mCi. The LOQ values for each dose calibrator were as follows dose calibrator Atomlab 100 = 7,88 µCi, Atomlab 300 = 12,65 µCi, Atomlab 400 = 17,32 µCi, Atomlab 500 = 15,06 µCi, and Capintec CRC tR5 = 18,6 µCi. As well as the LOQ values of the dose calibrator were determined as calibrator Atomlab 100 = 2,74 µCi, Atomlab 300 = 1,14 µCi, Atomlab 400 = 8,2 µCi, Atomlab 500 = 6,79 µCi, and Capintec CRC tR5 = 7,38 µCi. These showed that five dose calibrator types offer reliable measurement validity with a 95% confidence level. Nevertheless, it is necessary to employ a correction factor for Atomlab 100, Atomlab 500, and Capintec CRC tR5.