Claim Missing Document
Check
Articles

Found 2 Documents
Search

PERANCANGAN DAN ANALISA KELAYAKAN PEMBANGUNAN SISTEM PHOTOVOLTAIC BERKAPASITAS 60 KWP DI PEMBANGKIT PEMARON Nurdiansyah, Rian; Hamdani, Yuda Muhammad; Rahayu, Andri Ulus
Journal of Energy and Electrical Engineering Vol 3, No 2: 30 April 2022
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v3i2.4715

Abstract

Perencanaan pembangunan Photovoltaic (PV) di pembangkit Pemaron ditujukan sebagai salah satu upaya untuk menurunkan penggunaan daya dari jaringan listrik PLN. Dengan menggunakan PV diharapkan mampu memberikan pengurangan terhadap pemakaian listrik sendiri dari unit pembangkit dan gedung pembangkit Pemaron. Pada perancangannya digunakan sistem PV tanpa trafo karena listrik dari inverter langsung dijadikan sebagai sumber listrik untuk unit pembangkit Pemaron. Besarnya daya dari inverter yang digunakan adalah sesuai dengan pemakaian daya di pembangkit Pemaron itu sendiri yaitu 54.388 watt, atau dibulatkan menjadi 60kW. Sebagai pembangkitannya digunakan modul PV dengan kemampuan hingga 200 watt, sehingga diperlukan 300 buah modul dengan kombinasi rangkaian seri dan paralel untuk mendapatkan tegangan dan arus yang sesuai dengan spesifikasi inverter yang digunakan. Pemasangan sistem PV ini dapat memberikan kontribusi terhadap penghematan dalam penggunaan listrik dari PLN dengan memperhitungkan 25 tahun masa pakai efektif PV sekitar 25 tahun dengan nilai sekitar US$ 126.081.
Optimization Design of Single-Tuned Passive Filter Using Particle Swarm Optimization Algorithm in Industry Malik, Mochamad Irlan; Hamdani, Yuda Muhammad; Yanti, Yanti
Journal of Energy and Electrical Engineering Vol 6, No 2: April 2025
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v6i2.14644

Abstract

In the industrial sector, the widespread use of non-linear loads such as inverters and variable speed drives has led to increased harmonic distortion, which negatively impacts power quality. These harmonics can cause equipment malfunctions, overheating, reduced system efficiency, and potential failures in power infrastructure. This study aims to optimize the design of a Single-Tuned Passive Filter (STPF) using the Particle Swarm Optimization (PSO) algorithm to minimize harmonic distortion in industrial electrical systems. Harmonic measurements in a representative system revealed Total Harmonic Distortion of current (THDi) values of 20.2%, 20.3%, and 18.6% for phases L1, L2, and L3, respectively, with the 5th and 7th harmonic orders being the most dominant. Initial simulation using standard filtering reduced THDi to 3.03%, 3.10%, and 2.89%, but significant residual harmonics were still present. By applying a PSO-optimized STPF, the THDi was further reduced to 2.42%, 2.43%, and 2.23%, indicating a marked improvement in harmonic mitigation. These findings confirm that the PSO-based design approach effectively enhances filter performance, resulting in improved power quality, increased system reliability, and better protection of electrical equipment. The implementation of the optimized STPF is particularly valuable in industrial environments such as the automotive sector, where power stability and equipment longevity are critical.